Green Coffee on Kinetex 2.6u EVO C18 50x2.1mm @ 0.4mL/min
LC Conditions
Column
Kinetex 2.6 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
Brand
Kinetex
Part No
00B-4725-AN
Phase Name
EVO C18
Elution Type
Gradient
Mobile Phase
A: 20mM Potassium Phosphate pH 2.5
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
95
5
2
5
30
70
3
6
30
70
4
6.5
95
5
5
10
95
5
Flow Rate
0.40 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Chlorogenic Acid
-OEChem-05151001162D<br><br> 43 44 0 1 0 0 0 0 0999 V2000<br> 8.0622 -0.8060 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.2942 2.0600 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7942 -1.8060 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.5263 -0.8060 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.2942 2.0600 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7942 2.9260 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 0.6940 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.3060 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.3060 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7942 1.1940 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 8.9282 -0.3060 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 8.9282 0.6940 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.6603 0.6940 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7942 -0.8060 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 10.6603 -0.3060 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 10.2942 2.0600 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -0.3060 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.8060 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -0.3060 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.8060 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.3060 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.8060 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.8060 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.3060 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.8060 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9282 -0.9260 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.7162 1.2766 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.3176 0.5863 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.2708 0.5863 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.8723 1.2766 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.2573 -1.1160 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.1972 0.0040 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6742 2.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.3312 -2.1160 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 12.0632 -0.4960 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 11.6042 2.5969 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.4260 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.3140 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.3140 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -2.1160 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.9260 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.3140 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.9260 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 11 1 1 6 0 0 0<br> 1 17 1 0 0 0 0<br> 10 2 1 1 0 0 0<br> 2 33 1 0 0 0 0<br> 14 3 1 1 0 0 0<br> 3 34 1 0 0 0 0<br> 15 4 1 1 0 0 0<br> 4 35 1 0 0 0 0<br> 5 16 1 0 0 0 0<br> 5 36 1 0 0 0 0<br> 6 16 2 0 0 0 0<br> 7 17 2 0 0 0 0<br> 8 23 1 0 0 0 0<br> 8 42 1 0 0 0 0<br> 9 25 1 0 0 0 0<br> 9 43 1 0 0 0 0<br> 10 12 1 0 0 0 0<br> 10 13 1 0 0 0 0<br> 10 16 1 0 0 0 0<br> 11 12 1 0 0 0 0<br> 11 14 1 0 0 0 0<br> 11 26 1 0 0 0 0<br> 12 27 1 0 0 0 0<br> 12 28 1 0 0 0 0<br> 13 15 1 0 0 0 0<br> 13 29 1 0 0 0 0<br> 13 30 1 0 0 0 0<br> 14 15 1 0 0 0 0<br> 14 31 1 0 0 0 0<br> 15 32 1 0 0 0 0<br> 17 18 1 0 0 0 0<br> 18 19 2 0 0 0 0<br> 18 37 1 0 0 0 0<br> 19 20 1 0 0 0 0<br> 19 38 1 0 0 0 0<br> 20 21 2 0 0 0 0<br> 20 22 1 0 0 0 0<br> 21 23 1 0 0 0 0<br> 21 39 1 0 0 0 0<br> 22 24 2 0 0 0 0<br> 22 40 1 0 0 0 0<br> 23 25 2 0 0 0 0<br> 24 25 1 0 0 0 0<br> 24 41 1 0 0 0 0<br>M END
Compound Name
Chlorogenic Acid
CID
1794427
Molecular Formula
C16H18O9
Molecular Weight
354
No. Hydrogen Bond Acceptors
9
No. Hydrogen Bond Donors
6
Similar Applications
Reversed Phase
Green Coffee on Kinetex 2.6u EVO C18 100x2.1mm @ 0.4mL/min
Kinetex 2.6 µm EVO C18 100 Å, LC Column 100 x 2.1 mm, EA
23003
Reversed Phase
Green Coffee on Kinetex 2.6u EVO C18 50x2.1mm @ 0.8mL/min
Kinetex 2.6 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23002
Reversed Phase
Green Coffee on Kinetex 2.6u EVO C18 50x2.1mm @ 0.4mL/min
Kinetex 2.6 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23000
Reversed Phase
Chlorogenic Acid in Brewed Black Coffee using Kinetex 5u C18 100x4.6mm
Kinetex 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20834
Reversed Phase
Chlorogenic Acid in Commercial Green Coffee Energy Drink using Kinetex 5u C18 100x4.6mm
Kinetex 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20833
Reversed Phase
Echinacea on Luna C18(2)
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16971