Bupropion Extracted from Urine using Strata X-CW and Kinetex 5u EVO C18
LC Conditions
Column
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Kinetex
Part No
00F-4633-E0
Phase Name
EVO C18
Elution Type
Gradient
Mobile Phase
A: 5mM Ammonium Bicarbonate pH 9.0
B: Methanol
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
50
50
2
10
20
80
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Preparation Details
Description
Strata-X-CW 33 µm Polymeric Weak Cation, 60 mg / 3 mL, Tubes, 50/Pk
Part No
8B-S035-UBJ
Condition 1
3 mL Metahnol at 1 mL/min
Condition 2
3 mL Water at 1 mL/min
Load
Load 1.00 mL Sample diluted in 100mM Sodium Phosphate pH 6.8
Wash 1
3 mL 100mM Sodium Phosphate pH 6.8 at 1 mL/min
Dry
5 minutes
Elution 1
2 mL 5% Formic Acid in Acetonitrile at 0.5 mL/min
Evaporation
Evaporate to dryness
Reconstitute
500 µL 50:50 5mM Ammonium Bicarbonate pH 9.0 and Methanol
Order Items Used in This Application
- 1. Bupropion
-OEChem-06211003142D<br><br> 34 34 0 1 0 0 0 0 0999 V2000<br> 2.0000 -2.9330 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.5670 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.5670 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 2.0670 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.5670 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 6.3301 2.5670 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9641 2.9330 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9641 1.2010 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.0670 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.0670 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.9330 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.4330 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.4330 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.4330 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.4330 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.9330 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 1.8770 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 0.8770 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6401 2.0300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 2.8770 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0201 3.1039 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5010 3.2430 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6541 3.4700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4272 2.6230 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4272 0.8910 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2741 0.6640 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5010 1.5110 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1541 -0.4699 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -0.2430 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7741 0.6039 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -1.1230 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -1.1230 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -2.7430 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.5530 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 14 1 0 0 0 0<br> 2 10 2 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 17 1 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 8 1 0 0 0 0<br> 5 9 1 0 0 0 0<br> 5 10 1 0 0 0 0<br> 5 18 1 0 0 0 0<br> 6 19 1 0 0 0 0<br> 6 20 1 0 0 0 0<br> 6 21 1 0 0 0 0<br> 7 22 1 0 0 0 0<br> 7 23 1 0 0 0 0<br> 7 24 1 0 0 0 0<br> 8 25 1 0 0 0 0<br> 8 26 1 0 0 0 0<br> 8 27 1 0 0 0 0<br> 9 28 1 0 0 0 0<br> 9 29 1 0 0 0 0<br> 9 30 1 0 0 0 0<br> 10 11 1 0 0 0 0<br> 11 12 2 0 0 0 0<br> 11 13 1 0 0 0 0<br> 12 14 1 0 0 0 0<br> 12 31 1 0 0 0 0<br> 13 15 2 0 0 0 0<br> 13 32 1 0 0 0 0<br> 14 16 2 0 0 0 0<br> 15 16 1 0 0 0 0<br> 15 33 1 0 0 0 0<br> 16 34 1 0 0 0 0<br>M END
Compound Name
Bupropion
CID
444
Molecular Formula
C13H18ClNO
Molecular Weight
239
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
Tricyclic Antidepressants Panel by LC-MS/MS with Kinetex 2.6 um PS C18
Kinetex 2.6 µm PS C18 100 Å, LC Column 100 x 2.1 mm, Ea
25493
Reversed Phase
Bupropion related compounds on Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
23096
Reversed Phase
Bupropion Extracted from Urine using Strata X-CW and Kinetex 5u EVO C18
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
23095