Flurbiprofen on Lux 5µm Amylose-1 by SFC
LC Conditions
Column
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
Brand
Lux
Part No
00G-4732-E0
Phase Name
Amylose-1
Elution Type
Isocratic
Mobile Phase
A: CO2/(Methanol + 0.25% IPA + 0.25% TFA) 90:10 (v/v)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
3.00 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (30°C)
Detection Info
Sample Notes
Courtesy of Tanika Van Mulders, Debby Mangelings and Yvan Vander Heyden, Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel, Brussels, Belgium. Results of this analysis yielded: Alpha >1.1 and Resolution >2
Order Items Used in This Application
- 1. Flurbiprofen
- 2. Flurbiprofen
-OEChem-06211003152D<br><br> 31 32 0 1 0 0 0 0 0999 V2000<br> 2.0000 0.9050 0.0000 F 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.5950 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -2.0950 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.0950 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.0950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.5950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.5950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.5950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.5950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 3.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 3.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 3.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.9450 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -0.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -0.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 0.7150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5560 -2.0581 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -2.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1760 -3.1319 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 2.0950 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 2.0950 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 3.7150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 3.7150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 4.5250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -3.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 9 1 0 0 0 0<br> 2 13 1 0 0 0 0<br> 2 31 1 0 0 0 0<br> 3 13 2 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 11 1 0 0 0 0<br> 4 13 1 0 0 0 0<br> 4 19 1 0 0 0 0<br> 5 7 2 0 0 0 0<br> 5 8 1 0 0 0 0<br> 6 9 2 0 0 0 0<br> 6 10 1 0 0 0 0<br> 6 12 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 20 1 0 0 0 0<br> 8 10 2 0 0 0 0<br> 8 21 1 0 0 0 0<br> 10 22 1 0 0 0 0<br> 11 23 1 0 0 0 0<br> 11 24 1 0 0 0 0<br> 11 25 1 0 0 0 0<br> 12 14 2 0 0 0 0<br> 12 15 1 0 0 0 0<br> 14 16 1 0 0 0 0<br> 14 26 1 0 0 0 0<br> 15 17 2 0 0 0 0<br> 15 27 1 0 0 0 0<br> 16 18 2 0 0 0 0<br> 16 28 1 0 0 0 0<br> 17 18 1 0 0 0 0<br> 17 29 1 0 0 0 0<br> 18 30 1 0 0 0 0<br>M END
Compound Name
Flurbiprofen
CID
3394
Molecular Formula
C15H13FO2
Molecular Weight
244
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
1
Similar Applications
Chiral
Lux i-Amylose-3 Separation for Flurbiprofen
Lux 5 µm i-Amylose-3, LC Column 250 x 4.6 mm, Ea
25352
Chiral
Flurbiprofen on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23298
Chiral
Flurbiprofen on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23285
Chiral
Flurbiprofen on LUX Amylose-1 5u in RP
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23206
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21139
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21138
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21137
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21136
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21135
Flurbiprofen on Lux 5µm Amylose-2 by SFC
21134
NSAIDs on Onyx C18 (Luna Comparison)
15649
Reversed Phase
Fluoropharmaceuticals using Synergi Fusion-RP
Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
14846