Organic Acids on Kinetex 2.6u Polar C18 150x4.6mm
LC Conditions
Column
Kinetex 2.6 µm Polar C18 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Kinetex
Part No
00F-4759-E0
Phase Name
Polar C18
Elution Type
Isocratic
Mobile Phase
A: 20mM Potassium Phosphate pH 1.5
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.50 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Malic Acid
- 2. Citric Acid
- 3. Fumaric Acid
- 4. Succinic Acid
-OEChem-06211003142D<br><br> 15 14 0 1 0 0 0 0 0999 V2000<br> 5.1350 -1.0950 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 -0.0950 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 0.4050 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 1.4050 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -1.0950 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -0.0950 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.2690 0.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 0.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -0.0950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8711 -0.5200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6675 0.8799 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8705 0.8799 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.4050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4040 0.2150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.0950 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 6 1 0 0 0 0<br> 1 13 1 0 0 0 0<br> 2 8 1 0 0 0 0<br> 2 14 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 3 15 1 0 0 0 0<br> 4 8 2 0 0 0 0<br> 5 9 2 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 8 1 0 0 0 0<br> 6 10 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 7 12 1 0 0 0 0<br>M END
Compound Name
Malic Acid
CID
525
Molecular Formula
C4H6O5
Molecular Weight
134
No. Hydrogen Bond Acceptors
5
No. Hydrogen Bond Donors
3
Similar Applications
Reversed Phase
Organic Acids on Luna Omega Polar 3u 150x4.6mm - 1.5 ml/min
Luna Omega 3 µm Polar C18 100 Å, LC Column 150 x 4.6 mm, Ea
25754
Reversed Phase
Organic Acids on Luna Omega Polar 3 µm C18 250 x 4.6mm
Luna Omega 5 µm Polar C18 100Å, LC Column 250 x 4.6 mm, EA
25736
Reversed Phase
Organic Acids on Luna Omega Polar 5u 250 x 4.6mm -
Luna Omega 5 µm Polar C18 100Å, LC Column 250 x 4.6 mm, EA
25735
Reversed Phase
Organic Acids on Luna Omega Polar 3u 150x4.6mm
Luna Omega 3 µm Polar C18 100 Å, LC Column 150 x 4.6 mm, Ea
25725
Reversed Phase
Aqueous Stablity Kinetex 2.6u F5 100x4.6mm (Organic Acids)
Kinetex 2.6 µm F5 100 Å, LC Column 100 x 4.6 mm, Ea
22806
Reversed Phase
Antihistamines using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22716
Reversed Phase
Organic Acids in Beer
Aqua 5 µm C18 125 Å, LC Column 250 x 4.6 mm, Ea
14171
Ion Exclusion
Sugars in Cucumber Juice on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
3147