Analysis of 23 PFASs in Butter using Luna® Omega 1.6 µm PS C18

Analysis of 23 PFASs in Butter using Luna® Omega 1.6 µm PS C18
LC Conditions
Column

Luna Omega 1.6µm PS C18 100Å, LC Column 100 x 2.1 mm, EA

Brand

Luna Omega

Part No

00D-4752-AN

Phase Name

PS C18

Elution Type

Gradient

Mobile Phase

A: 5 mM Ammonium Acetate/Water

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

60

40

2

0.5

60

40

3

3

10

90

4

3.1

0

100

5

4

0

100

Flow Rate

0.55 mL/min

Temperature

40°C

Detection

Tandem Mass Spec (MS-MS) @ (22°C)

Detection Info

Order Items Used in This Application

Luna Omega 1.6µm PS C18 100Å, LC Column 100 x 2.1 mm, EA
00D-4752-AN

Luna Omega 1.6µm PS C18 100Å, LC Column 100 x 2.1 mm, EA

View Product

  • 1. 6:2 FTS
  • 2. 8:2 FTS
  • 3. EtFOSA
  • 4. EtFOSE
  • 5. FOSA
  • 6. MeFOSA
  • 7. MeFOSE
  • 8. PFBA
  • 9. PFBS
  • 10. PFDA
  • 11. PFDoA
  • 12. PFDS
  • 13. PFHpA
  • 14. PFHpS
  • 15. PFHxA
  • 16. PFHxS
  • 17. PFNA
  • 18. PFOA
  • 19. PFOS
  • 20. PFPeA
  • 21. PFTeDA
  • 22. PFTrDA
  • 23. PFUdA
Similar Applications