GC Conditions
Column

Zebron ZB-DHA-PONA, GC Cap. Column 100m x 0.25mm x 0.5µm, Ea

Part No

7MG-G042-17

Phase Name

ZB-DHA-PONA

Injection

Split 40:1 @ 300°C

Inlet Liner

AG2-0A11-05

Oven Program

35°C for 14 min to 60°C @ 1.1°C/min 60°C for 19 min to 280°C @ 2°C/min 280°C for 5 min

Carrier Gas

Constant Flow Helium, 1.6 mL/min

System

Agilent Technologies 6890 HP 6890

Detection

GC/FID @ (320°C)

Detection Info
Sample Notes

The pariffins standard was first diluted 100:1 in pentane and then run with a 40:1 split to avoid column overloading.