Cough and Cold
LC Conditions
Column
Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4249-E0
Phase Name
C8(2)
Elution Type
Isocratic
Mobile Phase
A: Methanol
B: Acetonitrile w/ 0.1% H3PO4
C: Water w/0.1% H3PO4 and 0.1% heptane sulfonate
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
40
10
Flow Rate
1.50 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C8 4 x 3.0mm, 10/Pk Part No.: AJ0-4290 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Acetaminophen
- 2. Pseudoephedrine
- 3. Benzoic acid
- 4. Chlorphenaramine
- 5. Dextromethorphan
-OEChem-06211003142D<br><br> 20 20 0 0 0 0 0 0 0999 V2000<br> 2.8660 -2.5950 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.4050 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.4050 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.0950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.0950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.0950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.0950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.5950 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 2.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.2150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 0.2150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 1.7150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.4050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.4050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3520 2.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 3.5250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1120 2.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -2.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 9 1 0 0 0 0<br> 1 20 1 0 0 0 0<br> 2 10 2 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 10 1 0 0 0 0<br> 3 14 1 0 0 0 0<br> 4 5 2 0 0 0 0<br> 4 6 1 0 0 0 0<br> 5 7 1 0 0 0 0<br> 5 12 1 0 0 0 0<br> 6 8 2 0 0 0 0<br> 6 13 1 0 0 0 0<br> 7 9 2 0 0 0 0<br> 7 15 1 0 0 0 0<br> 8 9 1 0 0 0 0<br> 8 16 1 0 0 0 0<br> 10 11 1 0 0 0 0<br> 11 17 1 0 0 0 0<br> 11 18 1 0 0 0 0<br> 11 19 1 0 0 0 0<br>M END
Compound Name
Acetaminophen
CID
1983
Molecular Formula
C8H9NO2
Molecular Weight
151
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
2
Similar Applications
Reversed Phase
Cold medicine compounds on Kinetex 2.6 µm EVO C18
Kinetex 2.6 µm EVO C18 100 Å, LC Column 100 x 4.6 mm, EA
23036
Reversed Phase
Pharmaceutical drug mix using Kinetex 5u C18 100x4.6mm
Kinetex 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20885
Reversed Phase
KNX 5 Brochure - Pharma mix analysis using Kinetex 5um C18 150x4.6mm
Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
20738
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 1.7u C18 100x2.1mm @ 0.60mL/min
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20054
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6u C18 100x2.1mm @ 0.60mL/min
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20053
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6 C18 100x2.1mm @ 1.0mL/min
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20050
Reversed Phase
Pharma ABN Test 15 Mix on Un-Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20049
Reversed Phase
Pharma ABN Test 15 Mix on Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20048
Reversed Phase
USP Acetaminophen Acetylsalicylic Acid Caffeine on Kinetex 1.7u C18 100x2.10mm on Shimadzu Nexera
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19959
Reversed Phase
USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x2.10mm on Shimadzu Nexera
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19958
Reversed Phase
USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 75x4.60mm on Shimadzu Nexera
Kinetex 2.6 µm C18 100 Å, LC Column 75 x 4.6 mm, Ea
19957
Reversed Phase
USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x4.60mm on Shimadzu Nexera
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
19956
Reversed Phase
Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19944
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotien Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19941
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 100 x 2.1mm @ 0.85 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19940
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 75 x 2.1mm @ 1.1 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 75 x 2.1 mm, Ea
19939
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19914
Reversed Phase
Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19911
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19862
Reversed Phase
Pharmaceutical Mixture on Kinetex 2.6µm C8 50x2.1mm ID
Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea
19476
Reversed Phase
Pharmaceutical Mixture on Kinetex XB-C18
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19475
Reversed Phase
Pharmaceutical Mixture on Kinetex C18
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19474
Application Specific
Drug screen by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18175
Standard
Drug Screen on ZB-XLB
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea
16463
Drug screen on ZB-5MSi
16421
High Temperature
Drug Screen on ZB-1HT
Zebron ZB-1HT, GC Cap. Column 30 m x 0.25 mm x 0.10 µm, Ea
16227
Standard
Common Drug Screen on ZB-35
Zebron ZB-35, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16010
Reversed Phase
Analgesics and Anti-Inflammatories
Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea
10254