USP Chloroquine Phosphate Assay on Luna 5 µm C18(2) 150 x 4.6 mm - System suitability
LC Conditions
Column
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4252-E0
Phase Name
C18(2)
Elution Type
Gradient
Mobile Phase
A: A = 0.4% triethylamine in methanol and Buffer (70:30) (Buffer: 1.4 g/L of anhydrous dibasic sodium phosphate in water. Adjust with 10% phosphoric acid to a pH of 3.0)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
2
20
100
Flow Rate
1.00 mL/min
Temperature
26°C
System
Agilent Technologies 1260 Infinity Agilent Technologies 1260 Infinity
Detection
LC/UV (DAD, PDA) @ 260 nm (nanometers) (26°C)
Detection Info
Sample Notes
Sample was at 2 µg/mL
Order Items Used in This Application
- 1. Phenol
- 2. CQ Related Compound G (4-((7-chloroquinolin-4-yl)amino)-N,N-diethylpentan-1-amine oxide sulfate)
- 3. CQ Related Compound D (7-Chloro-4-{[4-(ethylamino)-1-methylbutyl] amino} quinoline)
- 4. Hydroxychloroquine sulfate
- 5. CQ Related Compound A (4,7-dichloroquinoline)
- 6. Chloroquine (CQ) phosphate
- 7. CQ Related Compound E (N4-(5-chloroquinolin-4-yl)-N1,N1-diethylpentane-1,4-diamine oxalate)
-OEChem-06211003142D<br><br> 13 13 0 0 0 0 0 0 0999 V2000<br> 2.8660 1.3450 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.3450 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.1550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.6550 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 0.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.1550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.4650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.4650 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.2750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 1.6550 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 2 1 0 0 0 0<br> 1 13 1 0 0 0 0<br> 2 3 2 0 0 0 0<br> 2 4 1 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 8 1 0 0 0 0<br> 4 6 2 0 0 0 0<br> 4 9 1 0 0 0 0<br> 5 7 2 0 0 0 0<br> 5 10 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 11 1 0 0 0 0<br> 7 12 1 0 0 0 0<br>M END
Compound Name
Phenol
CID
996
Molecular Formula
C6H6O
Molecular Weight
94
No. Hydrogen Bond Acceptors
1
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
USP Chloroquine Phosphate Assay on Kinetex 5 µm C18 150 x 4.6 mm - System Suitability
Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
25925
Reversed Phase
USP Chloroquine Phosphate Assay on Luna 5 µm C18(2) 150 x 4.6 mm - System suitability
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
25923
Improved Performance
Zebon ZB-624PLUS QC Test Mix
Zebron ZB-624plus, GC Cap. Column 30m x 0.32mm x 1.8um, Ea
25001
Reversed Phase
Cold Medications on Luna 3u Polar C18 100x4.6mm
Luna Omega 3 µm Polar C18 100 Å, LC Column 100 x 4.6 mm, Ea
24046
Reversed Phase
Analgesics Mix 9 on Luna Omega 1.6u C18 50x2.1mm
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
23485
Reversed Phase
Phenol Selectivity Luna Omega 1.6u C18 50x2.1mm
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
23434
Reversed Phase
Cold medicine compounds on Kinetex 2.6 µm EVO C18
Kinetex 2.6 µm EVO C18 100 Å, LC Column 100 x 4.6 mm, EA
23036
Reversed Phase
Substituted Phenol Isomers on a Kinetex 2.6 µm F5 150 x 4.6
Kinetex 2.6 um F5 100 A,LC Column 150 x 4.6 mm,Ea
22799
Reversed Phase
Caffeine and phenol using Kinetex 5u Biphenyl 50x4.6mm
Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 4.6 mm, Ea
22158
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 1.7u C18 100x2.1mm @ 0.60mL/min
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20054
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6u C18 100x2.1mm @ 0.60mL/min
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20053
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6 C18 100x2.1mm @ 1.0mL/min
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20050
Reversed Phase
Pharma ABN Test 15 Mix on Un-Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20049
Reversed Phase
Pharma ABN Test 15 Mix on Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20048
Reversed Phase
Pharmaceutical Mixture on Kinetex 2.6µm C8 50x2.1mm ID
Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea
19476
Reversed Phase
Pharmaceutical Mixture on Kinetex XB-C18
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19475
Reversed Phase
Pharmaceutical Mixture on Kinetex C18
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19474
Gel Permeation Chromatography (GPC)
Phenolic Resins
Phenogel 5 µm 500 Å, LC Column 300 x 7.8 mm, Ea
5429