Dexamethasone USP Standard Solution on Kinetex 1.7 µm C18 100 x 2.1 mm on Agilent 1290 UHPLC
LC Conditions
Column
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
Brand
Kinetex
Part No
00D-4475-AN
Phase Name
C18
Elution Type
Gradient
Mobile Phase
A: 3.4 g/L of monobasic potassium phosphate in water. Adjust with phosphoric acid to a pH of 3.0
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
76
24
2
10
76
24
3
15
45
55
4
16
10
90
5
16.1
76
24
6
20
76
24
Flow Rate
0.40 mL/min
Temperature
35°C
System
Agilent Technologies Agilent Technologies 1290 Infinity
Detection
LC/UV (DAD, PDA) @ 240 nm (nanometers)
Detection Info
Order Items Used in This Application
- 1. Dexamethasone
-OEChem-06211003152D<br><br> 57 60 0 1 0 0 0 0 0999 V2000<br> 5.0182 -0.2293 0.0000 F 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0319 1.2610 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7950 0.5046 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.0622 0.4874 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.8566 2.4768 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -3.0477 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3931 0.0046 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 7.3931 -0.9954 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 6.5271 -1.4954 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 5.6610 -0.9954 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 8.3393 0.3094 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 8.3393 -1.3001 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5271 0.5046 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9229 -0.4954 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 5.6610 0.0046 0.0000 C 0 0 2 0 0 0 0 0 0 0 0 0<br> 4.7510 -1.5022 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 6.5431 -2.5369 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3931 1.0046 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6451 -3.0646 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7430 -2.5438 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.1493 0.8957 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.9229 -0.4954 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4163 -0.5599 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8242 -0.9381 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8076 -3.0935 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.0465 1.8904 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8763 -1.4661 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8680 -2.5510 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4830 -1.8406 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2664 -1.9147 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0883 -1.8670 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.8767 -1.6093 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9256 0.9796 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1285 0.9796 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.2046 -1.0477 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6610 0.6246 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7612 -3.1173 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1523 -2.4214 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0131 1.0046 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3931 1.6246 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7731 1.0046 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2478 -3.5406 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0460 -3.5375 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.9229 -1.1154 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.5429 -0.4954 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.9229 0.1246 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0005 -0.3524 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2087 0.0243 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8320 -0.7675 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.4476 1.7210 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8361 -0.3183 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7950 1.1246 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8100 -3.7135 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.7757 2.4482 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.4502 1.7206 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3430 -1.1499 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7928 3.0935 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10 1 1 6 0 0 0<br> 11 2 1 6 0 0 0<br> 2 50 1 0 0 0 0<br> 15 3 1 1 0 0 0<br> 3 52 1 0 0 0 0<br> 4 21 2 0 0 0 0<br> 5 26 1 0 0 0 0<br> 5 57 1 0 0 0 0<br> 6 28 2 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 7 13 1 0 0 0 0<br> 7 18 1 1 0 0 0<br> 8 9 1 0 0 0 0<br> 8 12 1 0 0 0 0<br> 8 29 1 6 0 0 0<br> 9 10 1 0 0 0 0<br> 9 17 1 0 0 0 0<br> 9 30 1 1 0 0 0<br> 10 15 1 0 0 0 0<br> 10 16 1 0 0 0 0<br> 11 14 1 0 0 0 0<br> 11 21 1 0 0 0 0<br> 12 14 1 0 0 0 0<br> 12 31 1 0 0 0 0<br> 12 32 1 0 0 0 0<br> 13 15 1 0 0 0 0<br> 13 33 1 0 0 0 0<br> 13 34 1 0 0 0 0<br> 14 22 1 6 0 0 0<br> 14 35 1 0 0 0 0<br> 15 36 1 0 0 0 0<br> 16 20 1 0 0 0 0<br> 16 23 1 1 0 0 0<br> 16 24 1 0 0 0 0<br> 17 19 1 0 0 0 0<br> 17 37 1 0 0 0 0<br> 17 38 1 0 0 0 0<br> 18 39 1 0 0 0 0<br> 18 40 1 0 0 0 0<br> 18 41 1 0 0 0 0<br> 19 20 1 0 0 0 0<br> 19 42 1 0 0 0 0<br> 19 43 1 0 0 0 0<br> 20 25 2 0 0 0 0<br> 21 26 1 0 0 0 0<br> 22 44 1 0 0 0 0<br> 22 45 1 0 0 0 0<br> 22 46 1 0 0 0 0<br> 23 47 1 0 0 0 0<br> 23 48 1 0 0 0 0<br> 23 49 1 0 0 0 0<br> 24 27 2 0 0 0 0<br> 24 51 1 0 0 0 0<br> 25 28 1 0 0 0 0<br> 25 53 1 0 0 0 0<br> 26 54 1 0 0 0 0<br> 26 55 1 0 0 0 0<br> 27 28 1 0 0 0 0<br> 27 56 1 0 0 0 0<br>M END
Compound Name
Dexamethasone
CID
5743
Molecular Formula
C22H29FO5
Molecular Weight
392
No. Hydrogen Bond Acceptors
6
No. Hydrogen Bond Donors
3
Similar Applications
Steroid mix on Waters XBridge 3.5 µm C18 150x4.6mm (Batch 3) using Agilent 1260 UHPLC System
26515
Steroid mix on Waters XBridge 3.5 µm C18 150x4.6mm (Batch 2) using Agilent 1260 UHPLC System
26514
Steroid mix on Waters XBridge 3.5 µm C18 150x4.6mm (Batch
- using Agilent 1260 UHPLC System
26513
Steroid mix on Agilent Zorbax SB-C18 3.5 µm 150x4.6mm (Batch 3) using Agilent 1260 UHPLC System
26512
Steroid mix on Agilent Zorbax SB-C18 3.5µm 150x4.6mm (Batch 2) using Agilent 1260 UHPLC System
26511
Reversed Phase
Steroid mix on Luna Omega 3 µm C18 150x4.6mm (Batch 3) using Agilent 1260 UHPLC System
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26509
Reversed Phase
Steroid mix on Luna Omega 3 µm C18 150x4.6mm (Batch 2) using Agilent 1260 UHPLC System
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26508
Reversed Phase
Steroid mix on Luna Omega 3 µm C18 150x4.6mm (Batch 1) using Agilent 1260 UHPLC System
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26503
Reversed Phase
Dexamethasone USP Organic Impurities Standard Solution on Kinetex 1.7 µm C18 100 x 2.1 mm on Agilent 1290 UHPLC
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
26288
Reversed Phase
Dexamethasone USP System Suitability Solution on Kinetex 1.7 µm C18 100 x 2.1 mm on Agilent 1290 UHPLC
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
26287
Reversed Phase
Dexamethasone USP Standard Solution on Kinetex 1.7 µm C18 100 x 2.1 mm on Agilent 1290 UHPLC
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
26286
Reversed Phase
Dexamethasone on Gemini 3 μm C18
Gemini 3 µm C18 110 Å, LC Column 100 x 4.6 mm, Ea
25980
Reversed Phase
Antibiotics by LCMS using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
22161