Tacrolimus Standard solution 3mg/mL - USP- Assay
LC Conditions
Column
Luna 3 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4251-E0
Phase Name
C18(2)
Elution Type
Gradient
Mobile Phase
A: Solution-A: 6mM Phosphoric acid in milliQ water. (0.4ml of 85% Orthophosphoric acid in 1000ml of water, filtered through 0.22µm membrane nylon filter)
Solution-B: A Mixture of Acetonitrile tert-butyl methyl in ratio of 810:190ml v/v. Solution A and Solution B in a ratio of 4:1 (400:100 ml v/v)
B: Solution-A: 6mM Phosphoric acid in milliQ water. (0.4ml of 85% Orthophosphoric acid in 1000ml of water, filtered through 0.22µm membrane nylon filter)
Solution-B: A Mixture of Acetonitrile tert-butyl methyl in ratio of 810:190ml v/v. Solution A and Solution B in a ratio of 1:4 (100:400 ml v/v)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
72
28
2
30
72
28
3
53
15
85
4
54
72
28
5
60
72
28
Flow Rate
1.50 mL/min
Temperature
60°C
System
Waters Arc HPLC Waters HPLC System
Detection
LC/UV (DAD, PDA) @ 220 nm (nanometers)
Detection Info
Sample Notes
Standard solution individual chromatogram
Order Items Used in This Application
- 1. Tacrolimus Open Ring
- 2. Tacrolimus 19-epimer
- 3. Tacrolimus
Similar Applications