Rhodamine Dyes
LC Conditions
Column
Luna 5 µm CN 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4255-E0
Phase Name
CN
Elution Type
Isocratic
Mobile Phase
A: 20mM Potassium phosphate, pH 3.0/Methanol (80:20)
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
50
50
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, CN 4 x 3.0mm, 10/Pk Part No.: AJ0-4305 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Rhodamine 123
- 2. Rhodamine B
- 3. Rhodamine 6G
-OEChem-05151001062D<br><br> 44 46 0 0 0 0 0 0 0999 V2000<br> 3.8147 0.0000 0.0000 Cl 0 5 0 0 0 0 0 0 0 0 0 0<br> 4.0682 3.1905 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2611 7.8038 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5619 6.0981 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5984 3.1664 0.0000 N 0 3 0 0 0 0 0 0 0 0 0 0<br> 0.5381 3.1664 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0682 5.1905 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9343 4.6905 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2022 4.6905 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0682 6.1905 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9343 3.6905 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2022 3.6905 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8282 5.2252 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3083 5.2252 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9343 6.6905 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8282 3.1558 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3083 3.1558 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2022 6.6905 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7343 3.6697 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4022 3.6697 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7343 4.7113 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4022 4.7113 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9343 7.6905 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2022 7.6905 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0682 8.1905 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9191 6.8642 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6183 8.5699 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8210 5.8451 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3154 5.8451 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8210 2.5359 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3154 2.5359 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6653 6.3805 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2700 5.0234 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 0.8665 5.0234 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4712 8.0005 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6653 8.0005 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0682 8.8105 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1365 3.4743 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5960 2.5464 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 0.0000 3.4743 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 0.5405 2.5464 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0933 8.9684 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2198 9.0448 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1434 8.1714 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2 11 1 0 0 0 0<br> 2 12 1 0 0 0 0<br> 3 26 1 0 0 0 0<br> 3 27 1 0 0 0 0<br> 4 26 2 0 0 0 0<br> 5 19 2 0 0 0 0<br> 5 38 1 0 0 0 0<br> 5 39 1 0 0 0 0<br> 6 20 1 0 0 0 0<br> 6 40 1 0 0 0 0<br> 6 41 1 0 0 0 0<br> 7 8 2 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 10 1 0 0 0 0<br> 8 11 1 0 0 0 0<br> 8 13 1 0 0 0 0<br> 9 12 2 0 0 0 0<br> 9 14 1 0 0 0 0<br> 10 15 1 0 0 0 0<br> 10 18 2 0 0 0 0<br> 11 16 2 0 0 0 0<br> 12 17 1 0 0 0 0<br> 13 21 2 0 0 0 0<br> 13 28 1 0 0 0 0<br> 14 22 2 0 0 0 0<br> 14 29 1 0 0 0 0<br> 15 23 2 0 0 0 0<br> 15 26 1 0 0 0 0<br> 16 19 1 0 0 0 0<br> 16 30 1 0 0 0 0<br> 17 20 2 0 0 0 0<br> 17 31 1 0 0 0 0<br> 18 24 1 0 0 0 0<br> 18 32 1 0 0 0 0<br> 19 21 1 0 0 0 0<br> 20 22 1 0 0 0 0<br> 21 33 1 0 0 0 0<br> 22 34 1 0 0 0 0<br> 23 25 1 0 0 0 0<br> 23 35 1 0 0 0 0<br> 24 25 2 0 0 0 0<br> 24 36 1 0 0 0 0<br> 25 37 1 0 0 0 0<br> 27 42 1 0 0 0 0<br> 27 43 1 0 0 0 0<br> 27 44 1 0 0 0 0<br>M CHG 2 1 -1 5 1<br>M END
Compound Name
Rhodamine 123
CID
65217
Molecular Formula
C21H17ClN2O3
Molecular Weight
380
No. Hydrogen Bond Acceptors
5
No. Hydrogen Bond Donors
2
Similar Applications