Bensulide and Thiram

Bensulide and Thiram
LC Conditions
Column

Cosmosil 5 µm C18-MS 120 Å, LC Column 150 x 4.6 mm, Ea

Brand

Cosmosil

Part No

CH0-3071

Phase Name

C18-MS

Elution Type

Isocratic

Mobile Phase

A: Acetonitrile

B: 0.05 M Phosphate buffer pH 3

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

60

40

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Cosmosil 5 µm C18-MS 120 Å, LC Column 150 x 4.6 mm, Ea
CH0-3071

Cosmosil 5 µm C18-MS 120 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Thiram
  • 2. Iprodione
  • 3. Bensulide
-OEChem-06211003152D<br><br> 24 23  0     0  0  0  0  0  0999 V2000<br>    4.5981   -0.2500    0.0000 S   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    0.2500    0.0000 S   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.2500    0.0000 S   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301   -1.2500    0.0000 S   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.2500    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1962    0.2500    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.0622   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1962    1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3100    0.7869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.6900   -0.2869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2460   -1.2500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.8700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4860   -1.2500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7522   -0.7869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.5991   -0.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.3722    0.2869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.8162    1.2500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1962    1.8700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5762    1.2500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  2  1  0  0  0  0<br>  1 11  1  0  0  0  0<br>  2 12  1  0  0  0  0<br>  3 11  2  0  0  0  0<br>  4 12  2  0  0  0  0<br>  5  7  1  0  0  0  0<br>  5  8  1  0  0  0  0<br>  5 11  1  0  0  0  0<br>  6  9  1  0  0  0  0<br>  6 10  1  0  0  0  0<br>  6 12  1  0  0  0  0<br>  7 13  1  0  0  0  0<br>  7 14  1  0  0  0  0<br>  7 15  1  0  0  0  0<br>  8 16  1  0  0  0  0<br>  8 17  1  0  0  0  0<br>  8 18  1  0  0  0  0<br>  9 19  1  0  0  0  0<br>  9 20  1  0  0  0  0<br>  9 21  1  0  0  0  0<br> 10 22  1  0  0  0  0<br> 10 23  1  0  0  0  0<br> 10 24  1  0  0  0  0<br>M  END
Compound Name

Thiram

CID

5455

Molecular Formula

C6H12N2S4

Molecular Weight

240

Similar Applications

Reversed Phase

Quantification of Carbamate Pesticides by QuEchERS and LC/MS/MS

Synergi 4 µm Fusion-RP 80 Å, LC Column 50 x 2 mm, Ea

20018