Diuretics

Diuretics
LC Conditions
Column

LiChrospher 5 µm RP-18 100 Å, LC Column 125 x 4 mm, Ea

Brand

LiChrospher

Part No

00E-3050-D0

Phase Name

RP-18

Elution Type

Isocratic

Mobile Phase

A: Acetonitrile

B: Water

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

30

70

Flow Rate

1.50 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282

Order Items Used in This Application

LiChrospher 5 µm RP-18 100 Å, LC Column 125 x 4 mm, Ea
00E-3050-D0

LiChrospher 5 µm RP-18 100 Å, LC Column 125 x 4 mm, Ea

View Product

  • 1. Chlorothiazide
  • 2. Hydrochlorothiazide
  • 3. Cyclothiazide
  • 4. Bendroflumethiazide
-OEChem-06211003152D<br><br> 23 24  0     0  0  0  0  0  0999 V2000<br>    3.4030    1.2327    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8950   -0.8020    0.0000 S   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030   -0.7673    0.0000 S   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.3849   -1.6737    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3850   -1.6622    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9030   -1.6333    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.9030    0.0987    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8950    1.2674    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.8010   -0.2881    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5369   -1.2673    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010   -0.2673    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010    0.7327    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -0.2673    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -0.7673    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    1.2327    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.7327    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.8010    0.7535    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -1.3873    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    1.8527    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8878    1.8873    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.3368    1.0656    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.9573    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5369   -1.8873    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 16  1  0  0  0  0<br>  2  4  2  0  0  0  0<br>  2  5  2  0  0  0  0<br>  2  9  1  0  0  0  0<br>  2 11  1  0  0  0  0<br>  3  6  2  0  0  0  0<br>  3  7  2  0  0  0  0<br>  3 10  1  0  0  0  0<br>  3 13  1  0  0  0  0<br>  8 12  1  0  0  0  0<br>  8 17  1  0  0  0  0<br>  8 20  1  0  0  0  0<br>  9 17  2  0  0  0  0<br> 10 22  1  0  0  0  0<br> 10 23  1  0  0  0  0<br> 11 12  1  0  0  0  0<br> 11 14  2  0  0  0  0<br> 12 15  2  0  0  0  0<br> 13 14  1  0  0  0  0<br> 13 16  2  0  0  0  0<br> 14 18  1  0  0  0  0<br> 15 16  1  0  0  0  0<br> 15 19  1  0  0  0  0<br> 17 21  1  0  0  0  0<br>M  END
Compound Name

Chlorothiazide

CID

2720

Molecular Formula

C7H6ClN3O4S2

Molecular Weight

295

No. Hydrogen Bond Acceptors

7

No. Hydrogen Bond Donors

2

Similar Applications

Reversed Phase

USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities- Amlodipine,Valsartan,Hydrochlorothiazide Standard solution Chromatogram USP-Impurities

Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

28202

Reversed Phase

USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities- Amlodipine,Valsartan,Hydrochlorothiazide Sensitivity solution Chromatogram USP-Impurities

Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

28201

Reversed Phase

USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities- Amlodipine,Valsartan,Hydrochlorothiazide System suitability solution Chromatogram USP-Impurities

Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

28200

Reversed Phase

USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities-Amlodipine,Valsartan,Hydrochlorothiazide Standard solution-SST Chromatogram USP-Assay

Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

28196