Diuretics
LC Conditions
Column
LiChrospher 5 µm RP-18 100 Å, LC Column 125 x 4 mm, Ea
Brand
LiChrospher
Part No
00E-3050-D0
Phase Name
RP-18
Elution Type
Isocratic
Mobile Phase
A: Acetonitrile
B: Water
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
30
70
Flow Rate
1.50 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Chlorothiazide
- 2. Hydrochlorothiazide
- 3. Cyclothiazide
- 4. Bendroflumethiazide
-OEChem-06211003152D<br><br> 23 24 0 0 0 0 0 0 0999 V2000<br> 3.4030 1.2327 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8950 -0.8020 0.0000 S 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -0.7673 0.0000 S 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3849 -1.6737 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3850 -1.6622 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9030 -1.6333 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9030 0.0987 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8950 1.2674 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8010 -0.2881 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -1.2673 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -0.2673 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 0.7327 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -0.2673 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -0.7673 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 1.2327 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.7327 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8010 0.7535 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -1.3873 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 1.8527 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8878 1.8873 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.3368 1.0656 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.9573 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -1.8873 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 16 1 0 0 0 0<br> 2 4 2 0 0 0 0<br> 2 5 2 0 0 0 0<br> 2 9 1 0 0 0 0<br> 2 11 1 0 0 0 0<br> 3 6 2 0 0 0 0<br> 3 7 2 0 0 0 0<br> 3 10 1 0 0 0 0<br> 3 13 1 0 0 0 0<br> 8 12 1 0 0 0 0<br> 8 17 1 0 0 0 0<br> 8 20 1 0 0 0 0<br> 9 17 2 0 0 0 0<br> 10 22 1 0 0 0 0<br> 10 23 1 0 0 0 0<br> 11 12 1 0 0 0 0<br> 11 14 2 0 0 0 0<br> 12 15 2 0 0 0 0<br> 13 14 1 0 0 0 0<br> 13 16 2 0 0 0 0<br> 14 18 1 0 0 0 0<br> 15 16 1 0 0 0 0<br> 15 19 1 0 0 0 0<br> 17 21 1 0 0 0 0<br>M END
Compound Name
Chlorothiazide
CID
2720
Molecular Formula
C7H6ClN3O4S2
Molecular Weight
295
No. Hydrogen Bond Acceptors
7
No. Hydrogen Bond Donors
2
Similar Applications
Reversed Phase
USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities- Amlodipine,Valsartan,Hydrochlorothiazide Standard solution Chromatogram USP-Impurities
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
28202
Reversed Phase
USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities- Amlodipine,Valsartan,Hydrochlorothiazide Sensitivity solution Chromatogram USP-Impurities
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
28201
Reversed Phase
USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities- Amlodipine,Valsartan,Hydrochlorothiazide System suitability solution Chromatogram USP-Impurities
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
28200
Reversed Phase
USP Amlodipine, Valsartan, and Hydrochlorothiazide Tablets –Assay and Impurities-Amlodipine,Valsartan,Hydrochlorothiazide Standard solution-SST Chromatogram USP-Assay
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
28196