LC Conditions
Column
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
Brand
Rezex
Part No
00H-0130-K0
Phase Name
RCM-Monosaccharide Ca+2 (8%)
Elution Type
Isocratic
Mobile Phase
A: Water
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
0.50 mL/min
Temperature
60°C
Detection
Refractive Index (RI) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Carbo-Ca 4 x 3.0mm, 10/Pk Part No.: AJ0-4493 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Glycerol
- 2. Methoxypolyethylene glycol
- 3. Triethylene glycol
- 4. Sorbitol
- 5. Urea
-OEChem-06211003142D<br><br> 14 13 0 0 0 0 0 0 0999 V2000<br> 4.2690 -0.5950 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 0.4050 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 0.4050 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.4050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 0.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 0.9050 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8059 0.0950 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5335 1.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7365 1.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8015 1.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.0044 1.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.9050 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5380 0.7150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.7150 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 4 1 0 0 0 0<br> 1 12 1 0 0 0 0<br> 2 5 1 0 0 0 0<br> 2 13 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 14 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 9 1 0 0 0 0<br> 6 10 1 0 0 0 0<br> 6 11 1 0 0 0 0<br>M END
Compound Name
Glycerol
CID
753
Molecular Formula
C3H8O3
Molecular Weight
92
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
3
Similar Applications
Ion Exclusion
Beer Well Drop on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16647
Ion Exclusion
25 Hr on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16646
Ion Exclusion
10 Hr on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16645
Ion Exclusion
6 Hr on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16644
Ion Exclusion
Yeast Prop. on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
16643
Improved Performance
Glycols and Benzene in Toothpaste Standard on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16510
Improved Performance
Glycols and Benzene in Toothpaste by FID on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16420
Normal Phase
Sugar Alcohols on Luna Amino
Luna 5 µm NH2 100 Å, LC Column 250 x 4.6 mm, Ea
14289
Ion Exclusion
Food Softeners
Rezex RCM-Monosaccharide Ca+2 (8%), LC Column 300 x 7.8 mm, Ea
5518
Ion Exclusion
Sugars in Cucumber Juice on Rezex ROA
Rezex ROA-Organic Acid H+ (8%), LC Column 300 x 7.8 mm, Ea
3147