Doxepin HCl - USP Method

Doxepin HCl - USP Method
LC Conditions
Column

Luna 5 µm C8(2) 100 Å, LC Column 125 x 4.6 mm, Ea

Brand

Luna

Part No

00E-4249-E0

Phase Name

C8(2)

Elution Type

Isocratic

Mobile Phase

A: 61:39 200mM Monobasic Sodium Phosphate:Methanol, adjusted to pH 2.5

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

1.00 mL/min

Temperature

50°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C8 4 x 3.0mm, 10/Pk Part No.: AJ0-4290 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Luna 5 µm C8(2) 100 Å, LC Column 125 x 4.6 mm, Ea
00E-4249-E0

Luna 5 µm C8(2) 100 Å, LC Column 125 x 4.6 mm, Ea

View Product

  • 1. Doxepin
  • 2. Doxepin
-OEChem-04281015372D<br><br> 42 44  0     0  0  0  0  0  0999 V2000<br>    5.3830    3.0953    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1509   -2.0953    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8830    0.9047    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9820    1.3386    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.7840    1.3385    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7595    2.3135    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0170   -0.5953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8830   -0.0953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0169   -1.5953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3830    3.0953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0065    2.3135    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.2295    0.6184    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.7690    2.6358    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5365    0.6184    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.9970    2.6358    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2318    0.9177    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    1.9333    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.5342    0.9177    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7660    1.9332    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1509   -3.0953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2849   -1.5953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8049   -0.0127    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4064   -0.7030    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4199   -0.4053    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2290   -2.1779    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6275   -1.4877    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5210    3.6998    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8244    3.3643    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.3744    0.0156    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6380    3.2418    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3916    0.0155    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1280    3.2418    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.7789    0.4943    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4083    2.1183    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.9871    0.4942    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.3578    2.1182    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5309   -3.0953    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1509   -3.7153    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7709   -3.0953    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5949   -1.0584    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.7480   -1.2853    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.9749   -2.1322    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 10  1  0  0  0  0<br>  1 11  1  0  0  0  0<br>  2  9  1  0  0  0  0<br>  2 20  1  0  0  0  0<br>  2 21  1  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3  8  2  0  0  0  0<br>  4  6  1  0  0  0  0<br>  4 12  2  0  0  0  0<br>  5 11  1  0  0  0  0<br>  5 14  2  0  0  0  0<br>  6 10  1  0  0  0  0<br>  6 13  2  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7  9  1  0  0  0  0<br>  7 22  1  0  0  0  0<br>  7 23  1  0  0  0  0<br>  8 24  1  0  0  0  0<br>  9 25  1  0  0  0  0<br>  9 26  1  0  0  0  0<br> 10 27  1  0  0  0  0<br> 10 28  1  0  0  0  0<br> 11 15  2  0  0  0  0<br> 12 16  1  0  0  0  0<br> 12 29  1  0  0  0  0<br> 13 17  1  0  0  0  0<br> 13 30  1  0  0  0  0<br> 14 18  1  0  0  0  0<br> 14 31  1  0  0  0  0<br> 15 19  1  0  0  0  0<br> 15 32  1  0  0  0  0<br> 16 17  2  0  0  0  0<br> 16 33  1  0  0  0  0<br> 17 34  1  0  0  0  0<br> 18 19  2  0  0  0  0<br> 18 35  1  0  0  0  0<br> 19 36  1  0  0  0  0<br> 20 37  1  0  0  0  0<br> 20 38  1  0  0  0  0<br> 20 39  1  0  0  0  0<br> 21 40  1  0  0  0  0<br> 21 41  1  0  0  0  0<br> 21 42  1  0  0  0  0<br>M  END
Compound Name

Doxepin

CID

667477

Molecular Formula

C19H21NO

Molecular Weight

279

No. Hydrogen Bond Acceptors

2

Similar Applications

Reversed Phase

USP Doxepin Assay - Standard Solution on Kinetex® 2.6 µm C8 75 x 4.6 mm

Kinetex 2.6 µm C8 100 Å, LC Column 75 x 4.6 mm, Ea

26361

Reversed Phase

USP Doxepin Assay - Standard Solution on Kinetex® 5 µm C8 150 x 4.6 mm

Kinetex 5 µm C8 100 Å, LC Column 150 x 4.6 mm, Ea

26360

Reversed Phase

USP Doxepin Assay - Standard Solution on Luna 5 µm C8(2) 150 x 4.6 mm

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea

26359

Reversed Phase

Fast Screening Method for 86 Forensic Analytes in Human Urine by LC-MS/MS

Luna 5 µm C18(2) 100 Å, LC Column 50 x 2 mm, Ea

25864

Reversed Phase

Tricyclic Antidepressants Panel by LC-MS/MS with Kinetex 2.6 um PS C18

Kinetex 2.6 µm PS C18 100 Å, LC Column 100 x 2.1 mm, Ea

25493

Reversed Phase

TCA's UV Kinetex 1.7µm C18 50x2.1mm Acquity UPLC

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19310

Reversed Phase

TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19309

Reversed Phase

TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19308

Reversed Phase

TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19307

Reversed Phase

TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19306

Standard

Antidepressants (Underivatized) on ZB-1701, 15 m x 0.25 mm x 0.25 µm

Zebron ZB-1701, GC Cap. Column 15 m x 0.25 mm x 0.25 µm, Ea

19295

Reversed Phase

MercuryMS - Luna 3µm C18(2) 20 x 2.0mm (mini column) for Tricyclics in Plasma by LC/MS/MS

Luna 3 µm C18(2) 100 Å, LC Column 20 x 2 mm, Ea

16043

MercuryMS - Synergi 2.5µm Fusion-RP 20 x 2.0mm for Tricyclics in Plasma by LC/MS/MS

16041