Prodigy PH-3 II (MeOH/Water 50:50)

Prodigy PH-3 II (MeOH/Water 50:50)
LC Conditions
Column

Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea

Brand

Prodigy

Part No

00F-4298-E0

Phase Name

Phenyl-3 (PH-3)

Elution Type

Isocratic

Mobile Phase

A: Methanol

B: Water

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

50

50

Flow Rate

1.00 mL/min

Temperature

30°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Phenyl 4 x 3.0mm, 10/Pk Part No.: AJ0-4351 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea
00F-4298-E0

Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Acetophenone
  • 2. Benzene
  • 3. Toluene
  • 4. Naphthalene
-OEChem-06211003152D<br><br> 17 17  0     0  0  0  0  0  0999 V2000<br>    2.0000    1.7500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.3700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0420    1.2131    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    2.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4220    2.2869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  5  2  0  0  0  0<br>  2  3  2  0  0  0  0<br>  2  4  1  0  0  0  0<br>  2  5  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3 10  1  0  0  0  0<br>  4  7  2  0  0  0  0<br>  4 11  1  0  0  0  0<br>  5  9  1  0  0  0  0<br>  6  8  2  0  0  0  0<br>  6 12  1  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7 13  1  0  0  0  0<br>  8 14  1  0  0  0  0<br>  9 15  1  0  0  0  0<br>  9 16  1  0  0  0  0<br>  9 17  1  0  0  0  0<br>M  END
Compound Name

Acetophenone

CID

7410

Molecular Formula

C8H8O

Molecular Weight

120

No. Hydrogen Bond Acceptors

1

Similar Applications

Reversed Phase

100 Make and Break Connections with SecurityLINK on Kinetex C18

Kinetex 1.3 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

25103

SecurityLINK vs Viper Zero Dead Volume Connections on Agilent Eclipse Plus C18 RRHD

25096

Reversed Phase

SecurityLINK VS Viper Zero Dead Volume Connections on Luna Omega C18

Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA

25095

Application Specific

EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

20582

Application Specific

Fast EPA Method 8270D on Zebron ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea

20572

Reversed Phase

Aeris WIDEPORE 3.6u XB-C18 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE XB-C18 200 Å, LC Column 150 x 2.1 mm, Ea

19812

Reversed Phase

Aeris 3.6u XB-C8 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE XB-C8 200 Å, LC Column 150 x 2.1 mm, Ea

19811

Reversed Phase

Aeris 3.6u C4 150 x 2.1mm ID QC Chromatogram (AL0-8931)

Aeris 3.6 µm WIDEPORE C4 200 Å, LC Column 150 x 2.1 mm, Ea

19810

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With KrudKatcher

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18803

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With Cartridge

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18802

Reversed Phase

SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm Without Cartridge

Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea

18801

High Temperature

EPA Method 8270C: Semivolatile Organics on ZB-XLB-HT

Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

18785

Application Specific

Drug screen by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18175

Standard

EPA Method 8270C on ZB-XLB

Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16584

EPA Method 8270C ZB-5MSi

16413

Application Specific

EPA Method 8270C on ZB-MR1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16275

Improved Performance

Industrial Chemicals: Ketones on ZB-WAXplus

Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea

16238

Standard

Industrial Chemicals: Ketones on ZB-624

Zebron ZB-624, GC Cap. Column 30 m x 0.53 mm x 3.00 µm, Ea

16232

Standard

Common Drug Screen on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

16009

Common Drug Screen on ZB-1MS

16008

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea

15696

Standard

EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

15695

Standard

EPA Method 8270C on ZB-5MS 30x0.25x0.25

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14953

Standard

EPA Method 8270C on Guardian on ZB-5

Zebron ZB-5 w/GUARDIAN, 5 m, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14945