Prodigy PH-3 II (MeOH/Water 50:50)
LC Conditions
Column
Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Prodigy
Part No
00F-4298-E0
Phase Name
Phenyl-3 (PH-3)
Elution Type
Isocratic
Mobile Phase
A: Methanol
B: Water
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
50
50
Flow Rate
1.00 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Phenyl 4 x 3.0mm, 10/Pk Part No.: AJ0-4351 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Acetophenone
- 2. Benzene
- 3. Toluene
- 4. Naphthalene
-OEChem-06211003152D<br><br> 17 17 0 0 0 0 0 0 0999 V2000<br> 2.0000 1.7500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0420 1.2131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 2.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4220 2.2869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 5 2 0 0 0 0<br> 2 3 2 0 0 0 0<br> 2 4 1 0 0 0 0<br> 2 5 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 10 1 0 0 0 0<br> 4 7 2 0 0 0 0<br> 4 11 1 0 0 0 0<br> 5 9 1 0 0 0 0<br> 6 8 2 0 0 0 0<br> 6 12 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 13 1 0 0 0 0<br> 8 14 1 0 0 0 0<br> 9 15 1 0 0 0 0<br> 9 16 1 0 0 0 0<br> 9 17 1 0 0 0 0<br>M END
Compound Name
Acetophenone
CID
7410
Molecular Formula
C8H8O
Molecular Weight
120
No. Hydrogen Bond Acceptors
1
Similar Applications
Reversed Phase
100 Make and Break Connections with SecurityLINK on Kinetex C18
Kinetex 1.3 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
25103
SecurityLINK vs Viper Zero Dead Volume Connections on Agilent Eclipse Plus C18 RRHD
25096
Reversed Phase
SecurityLINK VS Viper Zero Dead Volume Connections on Luna Omega C18
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
25095
Application Specific
EPA Method 8270D on Zebron ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
20582
Application Specific
Fast EPA Method 8270D on Zebron ZB-SemiVolatiles
Zebron ZB-SemiVolatiles, GC Cap. Column 20 m x 0.18 mm x 0.36 µm, Ea
20572
Reversed Phase
Aeris WIDEPORE 3.6u XB-C18 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE XB-C18 200 Å, LC Column 150 x 2.1 mm, Ea
19812
Reversed Phase
Aeris 3.6u XB-C8 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE XB-C8 200 Å, LC Column 150 x 2.1 mm, Ea
19811
Reversed Phase
Aeris 3.6u C4 150 x 2.1mm ID QC Chromatogram (AL0-8931)
Aeris 3.6 µm WIDEPORE C4 200 Å, LC Column 150 x 2.1 mm, Ea
19810
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With KrudKatcher
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18803
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm With Cartridge
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18802
Reversed Phase
SecurityGuard Comparisons on Jupiter 5u C18 300A 250 x 4.6mm Without Cartridge
Jupiter 5 µm C18 300 Å, LC Column 250 x 4.6 mm, Ea
18801
High Temperature
EPA Method 8270C: Semivolatile Organics on ZB-XLB-HT
Zebron ZB-XLB-HT, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
18785
Application Specific
Drug screen by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18175
Standard
EPA Method 8270C on ZB-XLB
Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16584
EPA Method 8270C ZB-5MSi
16413
Application Specific
EPA Method 8270C on ZB-MR1
Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
16275
Improved Performance
Industrial Chemicals: Ketones on ZB-WAXplus
Zebron ZB-WAXplus, GC Cap. Column 30 m x 0.53 mm x 1.00 µm, Ea
16238
Standard
Industrial Chemicals: Ketones on ZB-624
Zebron ZB-624, GC Cap. Column 30 m x 0.53 mm x 3.00 µm, Ea
16232
Standard
Common Drug Screen on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
16009
Common Drug Screen on ZB-1MS
16008
Standard
EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.32 µm, Ea
15696
Standard
EPA Method 8270C: Semivolatile Organic Analysis on ZB-5MS
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
15695
Standard
EPA Method 8270C on ZB-5MS 30x0.25x0.25
Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14953
Standard
EPA Method 8270C on Guardian on ZB-5
Zebron ZB-5 w/GUARDIAN, 5 m, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14945