Analgesics as a Probe for Phenyl Selectivity

Analgesics as a Probe for Phenyl Selectivity
LC Conditions
Column

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea

Brand

Luna

Part No

00F-4249-E0

Phase Name

C8(2)

Elution Type

Isocratic

Mobile Phase

A: 20 mM Ammonium formate pH 3.5

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

50

50

Flow Rate

2.00 mL/min

Temperature

25°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C8 4 x 3.0mm, 10/Pk Part No.: AJ0-4290 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea
00F-4249-E0

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Indoprofen
  • 2. Ethyl paraben
  • 3. Naproxen
  • 4. Indomethacin
  • 5. Ibuprofen
-OEChem-06211003152D<br><br> 36 38  0     1  0  0  0  0  0999 V2000<br>    4.9889    1.7436    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>   10.7619   -0.8776    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    9.2619   -1.7436    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2619   -0.0116    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6783   -0.8163    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.5116    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.4884    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.2619   -0.0116    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6783    0.7931    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.2619   -0.0116    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    9.2619   -0.0116    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    6.7619    0.8544    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.7619   -0.8776    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.0116    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7619    0.8544    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7619   -0.8776    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.9884    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.5116    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.4884    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    9.7619    0.8544    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    9.7619   -0.8776    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4272   -1.3832    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2156   -1.1256    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.9519    0.5253    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.4519    1.3914    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.4519   -1.4146    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.6316    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.0719    1.3914    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.0719   -1.4146    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.6084    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -0.8216    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.7984    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>   10.2988    0.5444    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>   10.0719    1.3914    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    9.2249    1.1644    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>   11.0719   -1.4146    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  9  2  0  0  0  0<br>  2 21  1  0  0  0  0<br>  2 36  1  0  0  0  0<br>  3 21  2  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4  8  1  0  0  0  0<br>  4  9  1  0  0  0  0<br>  5  6  1  0  0  0  0<br>  5 22  1  0  0  0  0<br>  5 23  1  0  0  0  0<br>  6  7  1  0  0  0  0<br>  6 14  2  0  0  0  0<br>  7  9  1  0  0  0  0<br>  7 17  2  0  0  0  0<br>  8 12  2  0  0  0  0<br>  8 13  1  0  0  0  0<br> 10 11  1  0  0  0  0<br> 10 15  2  0  0  0  0<br> 10 16  1  0  0  0  0<br> 11 20  1  0  0  0  0<br> 11 21  1  0  0  0  0<br> 11 24  1  0  0  0  0<br> 12 15  1  0  0  0  0<br> 12 25  1  0  0  0  0<br> 13 16  2  0  0  0  0<br> 13 26  1  0  0  0  0<br> 14 18  1  0  0  0  0<br> 14 27  1  0  0  0  0<br> 15 28  1  0  0  0  0<br> 16 29  1  0  0  0  0<br> 17 19  1  0  0  0  0<br> 17 30  1  0  0  0  0<br> 18 19  2  0  0  0  0<br> 18 31  1  0  0  0  0<br> 19 32  1  0  0  0  0<br> 20 33  1  0  0  0  0<br> 20 34  1  0  0  0  0<br> 20 35  1  0  0  0  0<br>M  END
Compound Name

Indoprofen

CID

3718

Molecular Formula

C17H15NO3

Molecular Weight

281

No. Hydrogen Bond Acceptors

3

No. Hydrogen Bond Donors

1

Similar Applications

Chiral

Lux i-Cellulose-5 Separation for Indoprofen

Lux 5 µm i-Cellulose-5, LC Column 250 x 4.6 mm, EA

25377

Chiral

Lux i-Amylose-1 Separation for Indoprofen

Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea

25376

Chiral

Lux i-Amylose-3 Separation for Indoprofen

Lux 5 µm i-Amylose-3, LC Column 250 x 4.6 mm, Ea

25375

Chiral

Chiral Separation of Indoprofen on Lux 5µm i-Amylose-1 in THF

Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea

24294

Reversed Phase

Pharmaceutical Mix on Kinetex 1.7 F5 50x2.1mm

Kinetex 1.7 µm F5 100 Å, LC Column 50 x 2.1 mm, Ea

22813

Indoprofen on Lux 5µm Amylose-2 in NP

20510

Chiral

Indoprofen on Lux 5µm Cellulose-1 in NP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

20471

Chiral

Indoprofen on Lux 5µm Cellulose-3 in RP

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20296

Chiral

Indoprofen on Lux Cellulose-3 with Methanol

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

19363

Reversed Phase

Luna - Analgesics#2

Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea

16900

Reversed Phase

Analgesics on Hyperclone 5u C8

HyperClone 5 µm MOS (C8) 120 Å, LC Column 150 x 4.6 mm, Ea

14701

Reversed Phase

Analgesics on Synergi Polar-RP

Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea

14250

Reversed Phase

Analgesics on Synergi Hydro-RP

Synergi 4 µm Hydro-RP 80 Å, LC Column 150 x 4.6 mm, Ea

14249

Reversed Phase

Analgesics as a Probe for Phenyl Selectivity

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea

10903

Reversed Phase

Analgesics as a Probe for Phenyl Selectivity

Synergi 4 µm Polar-RP 80 Å, LC Column 150 x 4.6 mm, Ea

10902

Reversed Phase

Analgesics and Anti-Inflammatories

Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea

10254