Parabens on Synergi Max-RP

Parabens on Synergi Max-RP
LC Conditions
Column

Synergi 4 µm Max-RP 80 Å, LC Column 150 x 4.6 mm, Ea

Brand

Synergi

Part No

00F-4337-E0

Phase Name

Max-RP

Elution Type

Isocratic

Mobile Phase

A: Acetonitrile

B: Water

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

50

50

Flow Rate

1.00 mL/min

Temperature

30°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C12 4 x 3.0mm, 10/Pk Part No.: AJ0-6074 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Synergi 4 µm Max-RP 80 Å, LC Column 150 x 4.6 mm, Ea
00F-4337-E0

Synergi 4 µm Max-RP 80 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Methyl paraben
  • 2. Ethyl paraben
  • 3. Propyl paraben
  • 4. Butyl paraben
Similar Applications