Leucine
LC Conditions
Column
Chirex 3126 (D)-penicillamine, LC Column 150 x 4.6 mm, Ea
Brand
Chirex
Part No
00F-3126-E0
Phase Name
3126 (D)-penicillamine
Elution Type
Isocratic
Mobile Phase
A: 2 mM Copper (II) sulfate in water
B: Methanol
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
85
15
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. L-Leucine
- 2. D-Leucine
-OEChem-06211003152D<br><br> 22 21 0 1 0 0 0 0 0999 V2000<br> 5.4641 0.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.0000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.0000 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.5000 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9441 -1.0826 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3426 -0.3923 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2460 -2.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4860 -2.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 0.0369 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -0.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 -1.0369 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 0.6900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 0.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 9 1 0 0 0 0<br> 1 22 1 0 0 0 0<br> 2 9 2 0 0 0 0<br> 6 3 1 6 0 0 0<br> 3 20 1 0 0 0 0<br> 3 21 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 8 1 0 0 0 0<br> 4 10 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 11 1 0 0 0 0<br> 5 12 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 13 1 0 0 0 0<br> 7 14 1 0 0 0 0<br> 7 15 1 0 0 0 0<br> 7 16 1 0 0 0 0<br> 8 17 1 0 0 0 0<br> 8 18 1 0 0 0 0<br> 8 19 1 0 0 0 0<br>M END
Compound Name
L-Leucine
CID
6106
Molecular Formula
C6H13NO2
Molecular Weight
131
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
2
Similar Applications
Normal Phase
Metabolites on Micro Luna NH2
Luna 3 µm NH2 100Å, LC Column 150 x 0.3 mm, Ea
26898
Reversed Phase
Metabolites on Micro Luna Omega 3 um Polar C18
Luna Omega 3 µm Polar C18 100 Å, LC Column 150 x 0.3 mm, Capillary, Ea
26896
HILIC
LC-MS/MS Separation of Amino Acid Isomers- Sarcosine, beta-Alanine, and L-Alanine- clone
bioZen 2.6 µm Glycan, LC Column 100 x 2.1 mm, Ea
25781
HILIC
LC-MS/MS Separation of Amino Acid Isomers- Leucine and Iso-Leucine
bioZen 2.6 µm Glycan, LC Column 100 x 2.1 mm, Ea
25780