EPA Method 639, Bendiocarb
LC Conditions
Official Method
EPA 639
Column
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4252-E0
Phase Name
C18(2)
Elution Type
Isocratic
Mobile Phase
A: Acetonitrile
B: Water
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
80
20
Flow Rate
1.50 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Bendiocarb
-OEChem-06211003142D<br><br> 29 30 0 0 0 0 0 0 0999 V2000<br> 5.5443 -0.6953 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5443 -2.3047 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.0000 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1279 -1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9369 -2.0878 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9369 -0.9122 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5725 -2.5894 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4385 -2.4522 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3014 -1.5862 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3014 -1.4138 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4385 -0.5478 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5725 -0.4106 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.1200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -0.6900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -2.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 2.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 3.0369 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 1.9631 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 6 1 0 0 0 0<br> 1 7 1 0 0 0 0<br> 2 6 1 0 0 0 0<br> 2 8 1 0 0 0 0<br> 3 11 1 0 0 0 0<br> 3 15 1 0 0 0 0<br> 4 15 2 0 0 0 0<br> 5 15 1 0 0 0 0<br> 5 16 1 0 0 0 0<br> 5 26 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 10 1 0 0 0 0<br> 7 8 2 0 0 0 0<br> 7 11 1 0 0 0 0<br> 8 12 1 0 0 0 0<br> 9 17 1 0 0 0 0<br> 9 18 1 0 0 0 0<br> 9 19 1 0 0 0 0<br> 10 20 1 0 0 0 0<br> 10 21 1 0 0 0 0<br> 10 22 1 0 0 0 0<br> 11 13 2 0 0 0 0<br> 12 14 2 0 0 0 0<br> 12 23 1 0 0 0 0<br> 13 14 1 0 0 0 0<br> 13 24 1 0 0 0 0<br> 14 25 1 0 0 0 0<br> 16 27 1 0 0 0 0<br> 16 28 1 0 0 0 0<br> 16 29 1 0 0 0 0<br>M END
Compound Name
Bendiocarb
CID
2314
Molecular Formula
C11H13NO4
Molecular Weight
223
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
Pesticide panel using Kinetex 2.6u Polar C18 50x4.6mm
Kinetex 2.6 µm Polar C18 100 Å, LC Column 50 x 4.6 mm, Ea
24017
Reversed Phase
185 Pesticides on Kinetex Biphenyl 5u
Kinetex 5 µm Biphenyl 100 Å, LC Column 100 x 2.1 mm, Ea
22618
Reversed Phase
EPA Method 639, Bendiocarb
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
14487