Children's Tylenol Cold on Luna SCX

Children's Tylenol Cold on Luna SCX
LC Conditions
Column

Luna 5 µm SCX 100 Å, LC Column 150 x 4.6 mm, Ea

Brand

Luna

Part No

00F-4398-E0

Phase Name

SCX

Elution Type

Isocratic

Mobile Phase

A: 50mM KH2PO4, pH 2.5

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

35

65

Flow Rate

1.50 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, SCX 4 x 3.0mm, 10/Pk Part No.: AJ0-4308 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Luna 5 µm SCX 100 Å, LC Column 150 x 4.6 mm, Ea
00F-4398-E0

Luna 5 µm SCX 100 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Acetaminophen
  • 2. Pseudoephedrine
  • 3. Dextromethorphan
  • 4. Chlorpheniramine
-OEChem-06211003142D<br><br> 20 20  0     0  0  0  0  0  0999 V2000<br>    2.8660   -2.5950    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    1.4050    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.4050    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.4050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.0950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.5950    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    2.9050    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.2150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    0.2150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    1.7150    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.4050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.4050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3520    2.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    3.5250    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1120    2.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291   -2.9050    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  9  1  0  0  0  0<br>  1 20  1  0  0  0  0<br>  2 10  2  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3 10  1  0  0  0  0<br>  3 14  1  0  0  0  0<br>  4  5  2  0  0  0  0<br>  4  6  1  0  0  0  0<br>  5  7  1  0  0  0  0<br>  5 12  1  0  0  0  0<br>  6  8  2  0  0  0  0<br>  6 13  1  0  0  0  0<br>  7  9  2  0  0  0  0<br>  7 15  1  0  0  0  0<br>  8  9  1  0  0  0  0<br>  8 16  1  0  0  0  0<br> 10 11  1  0  0  0  0<br> 11 17  1  0  0  0  0<br> 11 18  1  0  0  0  0<br> 11 19  1  0  0  0  0<br>M  END
Compound Name

Acetaminophen

CID

1983

Molecular Formula

C8H9NO2

Molecular Weight

151

No. Hydrogen Bond Acceptors

2

No. Hydrogen Bond Donors

2

Similar Applications

Reversed Phase

Alternative Column for USP Monograph-227: 4-Aminophenol in Acetaminophen-Containing Drug Products_Sample solution on Kinetex EVO C18, 5 µm 150 x 4.6 mm 100 Å.

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

28424

Reversed Phase

Alternative Column for USP Monograph-227: 4-Aminophenol in Acetaminophen-Containing Drug Products_Standard solution on Kinetex EVO C18, 5 µm 150 x 4.6 mm 100 Å.

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

28422

Reversed Phase

Alternative Column for USP Monograph-227: 4-Aminophenol in Acetaminophen-Containing Drug Products_Sample solution on Luna Omega PS C18, 5 µm 150 x 4.6 mm 100 Å.

Luna Omega 5 µm PS C18 100Å, LC Column 150 x 4.6 mm, EA

28418

Reversed Phase

Alternative Column for USP Monograph-227: 4-Aminophenol in Acetaminophen-Containing Drug Products_Standard solution on Luna Omega PS C18, 5 µm 150 x 4.6 mm 100 Å.

Luna Omega 5 µm PS C18 100Å, LC Column 150 x 4.6 mm, EA

28416

Reversed Phase

Kinetex 2.6u C18 100A and LC Column 150 x 0.3 mm- Pharma Screen

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 0.3 mm, Capillary, Ea

26400

Reversed Phase

Kinetex 2.6u C18 100A, LC Column 50 x 0.3 mm- Pharma Screen

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 0.3 mm, Capillary, Ea

26399

Reversed Phase

Kinetex 2.6u XB-C18 100A, LC Column 50 x 0.3 mm- Pharma Screen

Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 0.3 mm, microflow, Ea

26324

Reversed Phase

Extraction of Acid, Basic, and Neutral Pharmaceuticals from Human Plasma Using Strata-X SPE on Kinetex 2.6 µm PS C18 LC Columns

Kinetex 2.6 µm PS C18 100 Å, LC Column 50 x 2.1 mm, Ea

25609

Reversed Phase

Resolution between Paracetamol and Paracetamol Impurity K (Ph.Eur.) on Kinetex 2.6 µm C18 100x2.1mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

25254

Reversed Phase

Cold medicine compounds on Kinetex 2.6 µm EVO C18

Kinetex 2.6 µm EVO C18 100 Å, LC Column 100 x 4.6 mm, EA

23036

Reversed Phase

Pharmaceutical drug mix using Kinetex 5u C18 100x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20885

Reversed Phase

KNX 5 Brochure - Pharma mix analysis using Kinetex 5um C18 150x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

20738

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 1.7u C18 100x2.1mm @ 0.60mL/min

Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20054

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6u C18 100x2.1mm @ 0.60mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20053

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6 C18 100x2.1mm @ 1.0mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20050

Reversed Phase

Pharma ABN Test 15 Mix on Un-Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20049

Reversed Phase

Pharma ABN Test 15 Mix on Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20048

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 2.6u C18 50x2.10mm @ 1.45mL/min 5min gradient

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20041

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 1.7u C18 50x2.10mm @ 1.0mL/min 5min gradient

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20040

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 2.6u C18 50x2.10mm @ 0.8mL/min 5 ming gradient

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20039

Reversed Phase

USP Acetaminophen Acetylsalicylic Acid Caffeine on Kinetex 1.7u C18 100x2.10mm on Shimadzu Nexera

Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19959

Reversed Phase

USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x2.10mm on Shimadzu Nexera

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19958

Reversed Phase

USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 75x4.60mm on Shimadzu Nexera

Kinetex 2.6 µm C18 100 Å, LC Column 75 x 4.6 mm, Ea

19957

Reversed Phase

USP Acetaminophen, Acetylsalicylic Acid, Caffeine on Kinetex 2.6u C18 100x4.60mm on Shimadzu Nexera

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

19956

Reversed Phase

Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19944

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotien Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19941

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 100 x 2.1mm @ 0.85 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19940

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 75 x 2.1mm @ 1.1 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 75 x 2.1 mm, Ea

19939

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19914

Reversed Phase

Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19911

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19862

Reversed Phase

Pharma ABN Test 11 Mix on Kinetex 2.6u C18 150x2.10mm using Acquity UPLC system

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 2.1 mm, Ea

19789

Reversed Phase

Pharma ABN Test 11 Mix on Kinetex 1.7u C18 150x2.10mm using Acquity UPLC system

Kinetex 1.7 µm XB-C18 100 Å, LC Column 150 x 2.1 mm, Ea

19788

Reversed Phase

Pharma ABN Test 12 Mix on Kinetex 1.7u C18 50x2.10mm using Acquity UPLC system

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19785

Reversed Phase

Pharma ABN Test 12 Mix on Kinetex 2.6u C18 50x2.10mm using Acquity UPLC system

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19784

Reversed Phase

Pharmaceutical Mixture on Kinetex 2.6µm C8 50x2.1mm ID

Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea

19476

Reversed Phase

Pharmaceutical Mixture on Kinetex XB-C18

Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea

19475

Reversed Phase

Pharmaceutical Mixture on Kinetex C18

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19474

Application Specific

Drug screen by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18175

Standard

Drug Screen on ZB-XLB

Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea

16463

Drug screen on ZB-5MSi

16421

High Temperature

Drug Screen on ZB-1HT

Zebron ZB-1HT, GC Cap. Column 30 m x 0.25 mm x 0.10 µm, Ea

16227

Standard

Common Drug Screen on ZB-35

Zebron ZB-35, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16010

Reversed Phase

Analgesics and Anti-Inflammatories

Prodigy 5 µm Phenyl-3 (PH-3) 100 Å, LC Column 150 x 4.6 mm, Ea

10254