Aroclor 1242 on ZB35 30m x .32mm x .25um

Aroclor 1242 on ZB35 30m x .32mm x .25um
GC Conditions
Column

Zebron ZB-35, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

Part No

7HM-G003-11

Phase Name

ZB-35

Injection

Split 15:1 @ 250°C

Oven Program

120°C for 1 min 300°C for 21 min 300°C for 26 min

Carrier Gas

Constant Flow Helium, 1.7 mL/min

Detection

Electron Capture (ECD) @ (375°C)

Detection Info

Order Items Used in This Application

Zebron ZB-35, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea
7HM-G003-11

Zebron ZB-35, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

View Product

  • 1. Aroclor 1242
-OEChem-05151001052D<br><br> 22 23  0     0  0  0  0  0  0999 V2000<br>    5.4641    0.0000    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.0000    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -3.0000    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    3.0000    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    2.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -3.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    0.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -1.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350    1.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    1.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -3.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  7  1  0  0  0  0<br>  2  9  1  0  0  0  0<br>  3 13  1  0  0  0  0<br>  4 15  1  0  0  0  0<br>  5  6  1  0  0  0  0<br>  5  7  2  0  0  0  0<br>  5  8  1  0  0  0  0<br>  6  9  2  0  0  0  0<br>  6 10  1  0  0  0  0<br>  7 11  1  0  0  0  0<br>  8 12  2  0  0  0  0<br>  8 17  1  0  0  0  0<br>  9 13  1  0  0  0  0<br> 10 14  2  0  0  0  0<br> 10 18  1  0  0  0  0<br> 11 15  2  0  0  0  0<br> 11 19  1  0  0  0  0<br> 12 15  1  0  0  0  0<br> 12 20  1  0  0  0  0<br> 13 16  2  0  0  0  0<br> 14 16  1  0  0  0  0<br> 14 21  1  0  0  0  0<br> 16 22  1  0  0  0  0<br>M  END
Compound Name

Aroclor 1242

CID

63103

Molecular Formula

C12H6Cl4

Molecular Weight

291

Similar Applications

Application Specific

Aroclor 1242 on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

16168

Standard

Aroclor 1242 on ZB35 30m x .32mm x .25um

Zebron ZB-35, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

14595

Standard

Aroclor 1242 on ZB 5 30m x .32mm x .25um

Zebron ZB-5, GC Cap. Column 30 m x 0.32 mm x 0.25 µm, Ea

14583

Standard

Aroclor 1242 on ZB5 15m x .32mm x .25um

Zebron ZB-5, GC Cap. Column 15 m x 0.32 mm x 0.25 µm, Ea

14571