QC Test on Hyperclone 3u C18

QC Test on Hyperclone 3u C18
LC Conditions
Column

HyperClone 3 µm ODS (C18) 120 Å, LC Column 100 x 4.6 mm, Ea

Brand

HyperClone

Part No

00D-4356-E0

Phase Name

ODS (C18)

Elution Type

Isocratic

Mobile Phase

A: Water

B: MeOH

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

30

70

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C18 4 x 3.0mm, 10/Pk Part No.: AJ0-4287 - Holder Part No.: KJ0-4282

Order Items Used in This Application

HyperClone 3 µm ODS (C18) 120 Å, LC Column 100 x 4.6 mm, Ea
00D-4356-E0

HyperClone 3 µm ODS (C18) 120 Å, LC Column 100 x 4.6 mm, Ea

View Product

  • 1. Benzamide
  • 2. Acetophenone
  • 3. Benzophenone
  • 4. Biphenyl
-OEChem-06211003142D<br><br> 16 16  0     0  0  0  0  0  0999 V2000<br>    2.0000    1.4400    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.4400    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.0600    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.5600    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.5600    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.5600    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.5600    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.0600    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.9400    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -0.2500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -0.2500    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631   -1.8700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.8700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -2.6800    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    2.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    1.1300    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  9  2  0  0  0  0<br>  2  9  1  0  0  0  0<br>  2 15  1  0  0  0  0<br>  2 16  1  0  0  0  0<br>  3  4  2  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3  9  1  0  0  0  0<br>  4  6  1  0  0  0  0<br>  4 10  1  0  0  0  0<br>  5  7  2  0  0  0  0<br>  5 11  1  0  0  0  0<br>  6  8  2  0  0  0  0<br>  6 12  1  0  0  0  0<br>  7  8  1  0  0  0  0<br>  7 13  1  0  0  0  0<br>  8 14  1  0  0  0  0<br>M  END
Compound Name

Benzamide

CID

2331

Molecular Formula

C7H7NO

Molecular Weight

121

No. Hydrogen Bond Acceptors

1

No. Hydrogen Bond Donors

1

Similar Applications

Chiral

3,5-dinitro-N-[(1R)-1-phenylethyl]benzamide on Lux 5µm Cellulose-3 in RP

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20292

Chiral

3,5-dinitro-N-[(1R)-1-phenylethyl]benzamide on Lux 3µm Cellulose-2 in NP

Lux 3 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

20275