Caffeine & Metabolites, pH 10.0 (Synergi 4µm Fusion-RP)
LC Conditions
Column
Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
Brand
Synergi
Part No
00F-4424-E0
Phase Name
Fusion-RP
Elution Type
Gradient
Mobile Phase
A: 20mM NH4HCO3, pH 10.0
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
98
2
2
15
80
20
Flow Rate
1.00 mL/min
Temperature
25°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (25°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Fusion-RP 4 x 3.0mm, 10/Pk Part No.: AJ0-7557 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Xanthine
- 2. Theobromine
- 3. Theophylline
- 4. Caffeine
-OEChem-06211003142D<br><br> 15 16 0 0 0 0 0 0 0999 V2000<br> 3.7320 1.8100 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.1900 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.1900 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5443 0.6147 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.3100 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5443 -0.9947 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.3100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.6900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.8100 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.6900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1279 -0.1900 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7369 1.2040 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 0.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7479 -0.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 9 2 0 0 0 0<br> 2 10 2 0 0 0 0<br> 3 8 1 0 0 0 0<br> 3 10 1 0 0 0 0<br> 3 12 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 11 1 0 0 0 0<br> 4 13 1 0 0 0 0<br> 5 9 1 0 0 0 0<br> 5 10 1 0 0 0 0<br> 5 14 1 0 0 0 0<br> 6 8 1 0 0 0 0<br> 6 11 2 0 0 0 0<br> 7 8 2 0 0 0 0<br> 7 9 1 0 0 0 0<br> 11 15 1 0 0 0 0<br>M END
Compound Name
Xanthine
CID
1188
Molecular Formula
C5H4N4O2
Molecular Weight
152
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
3
Similar Applications
Reversed Phase
Caffeine & Metabolites, pH 7.5 - Luna 5µm C18(2)
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
15662
Reversed Phase
Caffeine & Metabolites, pH 7.5 (Synergi 4µm Fusion-RP)
Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
15661
Reversed Phase
Caffeine & Metabolites, pH 10.0 - Luna 5µm C18(2)
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
15660
Reversed Phase
Caffeine & Metabolites, pH 10.0 (Synergi 4µm Fusion-RP)
Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
15659
Reversed Phase
Caffeine & Metabolites, pH 4.5 (Synergi 4µm Fusion-RP)
Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
15658
Reversed Phase
Caffeine & Metabolites, pH 4.5 - Luna 5µm C18(2)
Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
15657
Reversed Phase
Caffeine & Metabolites, pH 7.5
Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea
15014
Reversed Phase
Caffeine & Metabolites, pH 4.5
Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea
15013
Reversed Phase
Caffeine & Metabolites, pH 10.0
Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea
15012