Caffeine & Metabolites, pH 10.0 (Synergi 4µm Fusion-RP)

Caffeine & Metabolites, pH 10.0 (Synergi 4µm Fusion-RP)
LC Conditions
Column

Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea

Brand

Synergi

Part No

00F-4424-E0

Phase Name

Fusion-RP

Elution Type

Gradient

Mobile Phase

A: 20mM NH4HCO3, pH 10.0

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

98

2

2

15

80

20

Flow Rate

1.00 mL/min

Temperature

25°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (25°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Fusion-RP 4 x 3.0mm, 10/Pk Part No.: AJ0-7557 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
00F-4424-E0

Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Xanthine
  • 2. Theobromine
  • 3. Theophylline
  • 4. Caffeine
-OEChem-06211003142D<br><br> 15 16  0     0  0  0  0  0  0999 V2000<br>    3.7320    1.8100    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.1900    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.1900    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5443    0.6147    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.3100    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5443   -0.9947    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.3100    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -0.6900    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.8100    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.6900    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1279   -0.1900    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.7369    1.2040    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    0.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.7479   -0.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  9  2  0  0  0  0<br>  2 10  2  0  0  0  0<br>  3  8  1  0  0  0  0<br>  3 10  1  0  0  0  0<br>  3 12  1  0  0  0  0<br>  4  7  1  0  0  0  0<br>  4 11  1  0  0  0  0<br>  4 13  1  0  0  0  0<br>  5  9  1  0  0  0  0<br>  5 10  1  0  0  0  0<br>  5 14  1  0  0  0  0<br>  6  8  1  0  0  0  0<br>  6 11  2  0  0  0  0<br>  7  8  2  0  0  0  0<br>  7  9  1  0  0  0  0<br> 11 15  1  0  0  0  0<br>M  END
Compound Name

Xanthine

CID

1188

Molecular Formula

C5H4N4O2

Molecular Weight

152

No. Hydrogen Bond Acceptors

3

No. Hydrogen Bond Donors

3

Similar Applications

Reversed Phase

Caffeine & Metabolites, pH 7.5 - Luna 5µm C18(2)

Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea

15662

Reversed Phase

Caffeine & Metabolites, pH 7.5 (Synergi 4µm Fusion-RP)

Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea

15661

Reversed Phase

Caffeine & Metabolites, pH 10.0 - Luna 5µm C18(2)

Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea

15660

Reversed Phase

Caffeine & Metabolites, pH 10.0 (Synergi 4µm Fusion-RP)

Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea

15659

Reversed Phase

Caffeine & Metabolites, pH 4.5 (Synergi 4µm Fusion-RP)

Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea

15658

Reversed Phase

Caffeine & Metabolites, pH 4.5 - Luna 5µm C18(2)

Luna 5 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea

15657

Reversed Phase

Caffeine & Metabolites, pH 7.5

Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea

15014

Reversed Phase

Caffeine & Metabolites, pH 4.5

Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea

15013

Reversed Phase

Caffeine & Metabolites, pH 10.0

Gemini 5 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea

15012