Tricyclic Antidepressants on Gemini 3u C18

Tricyclic Antidepressants on Gemini 3u C18
LC Conditions
Column

Gemini 3 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea

Brand

Gemini

Part No

00F-4439-E0

Phase Name

C18

Elution Type

Isocratic

Mobile Phase

A: 20mM Phosphate buffer, pH 7

B: Acetonitrile

C: Methanol

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

30

35

Flow Rate

1.50 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Gemini C18 4 x 3.0mm, 10/Pk Part No.: AJ0-7597 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Gemini 3 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea
00F-4439-E0

Gemini 3 µm C18 110 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Nortriptyline
  • 2. Imipramine
  • 3. Amitriptyline
  • 4. Clomipramine
-OEChem-06211003152D<br><br> 41 43  0     0  0  0  0  0  0999 V2000<br>    3.1509   -2.0953    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3830    3.0953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3830    3.0953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7595    2.3135    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0065    2.3135    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8830    0.9047    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9820    1.3386    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.7840    1.3385    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8830   -0.0953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.7690    2.6358    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.9970    2.6358    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.2295    0.6184    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5365    0.6184    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0170   -0.5953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    1.9333    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7660    1.9332    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0169   -1.5953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2318    0.9177    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.5342    0.9177    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1509   -3.0953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5210    3.6998    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8244    3.3643    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.9416    3.3643    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2450    3.6998    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4199   -0.4053    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6380    3.2418    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1280    3.2418    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.3744    0.0156    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3916    0.0155    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8049   -0.0127    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4064   -0.7030    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2290   -2.1779    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6275   -1.4877    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4083    2.1183    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.3578    2.1182    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.7789    0.4943    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.9871    0.4942    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6140   -1.7853    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5309   -3.0953    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1509   -3.7153    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7709   -3.0953    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 17  1  0  0  0  0<br>  1 20  1  0  0  0  0<br>  1 38  1  0  0  0  0<br>  2  3  1  0  0  0  0<br>  2  4  1  0  0  0  0<br>  2 21  1  0  0  0  0<br>  2 22  1  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3 23  1  0  0  0  0<br>  3 24  1  0  0  0  0<br>  4  7  1  0  0  0  0<br>  4 10  2  0  0  0  0<br>  5  8  1  0  0  0  0<br>  5 11  2  0  0  0  0<br>  6  7  1  0  0  0  0<br>  6  8  1  0  0  0  0<br>  6  9  2  0  0  0  0<br>  7 12  2  0  0  0  0<br>  8 13  2  0  0  0  0<br>  9 14  1  0  0  0  0<br>  9 25  1  0  0  0  0<br> 10 15  1  0  0  0  0<br> 10 26  1  0  0  0  0<br> 11 16  1  0  0  0  0<br> 11 27  1  0  0  0  0<br> 12 18  1  0  0  0  0<br> 12 28  1  0  0  0  0<br> 13 19  1  0  0  0  0<br> 13 29  1  0  0  0  0<br> 14 17  1  0  0  0  0<br> 14 30  1  0  0  0  0<br> 14 31  1  0  0  0  0<br> 15 18  2  0  0  0  0<br> 15 34  1  0  0  0  0<br> 16 19  2  0  0  0  0<br> 16 35  1  0  0  0  0<br> 17 32  1  0  0  0  0<br> 17 33  1  0  0  0  0<br> 18 36  1  0  0  0  0<br> 19 37  1  0  0  0  0<br> 20 39  1  0  0  0  0<br> 20 40  1  0  0  0  0<br> 20 41  1  0  0  0  0<br>M  END
Compound Name

Nortriptyline

CID

4543

Molecular Formula

C19H21N

Molecular Weight

263

No. Hydrogen Bond Acceptors

1

No. Hydrogen Bond Donors

1

Similar Applications

Reversed Phase

ABN7 using Method Transfer Scaling Calculator on Luna Omega 5 µm C18 250 x 4.6 mm with Agilent 1260 Binary UHPLC

Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

26804

Reversed Phase

ABN7 using Method Transfer Scaling Calculator on Luna Omega 3 µm C18 150 x 4.6 mm with Agilent 1260 Binary UHPLC

Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

26803

Reversed Phase

ABN7 using Method Transfer Scaling Calculator on Luna Omega 1.6 µm C18 50 x 2.1 mm with Agilent 1260 Binary UHPLC

Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA

26802

ABN3 mix on Waters XBridge 5 µm C18 250x4.6mm (Batch 3) using Agilent 1260 Binary UHPLC system

26502

ABN3 mix on Waters XBridge 5 µm C18 250x4.6mm (Batch 2) using Agilent 1260 Binary UHPLC system

26501

ABN3 mix on Waters XBridge 5 µm C18 250x4.6mm (Batch 1) using Agilent 1260 Binary UHPLC system

26500

ABN3 mix on Agilent Zorbax SB-C18 5 µm 250x4.6mm (Batch 3) using Agilent 1260 Binary UHPLC system

26499

ABN3 mix on Agilent Zorbax SB-C18 5 µm 250x4.6mm (Batch 2) using Agilent 1260 Binary UHPLC system

26498

ABN3 mix on Agilent Zorbax SB-C18 5 µm 250x4.6mm (Batch

  1. using Agilent 1260 Binary UHPLC system

26497

Reversed Phase

ABN3 mix on Luna Omega 5 µm C18 250x4.6mm (Batch 3) using Agilent 1260 Binary UHPLC system

Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

26496

Reversed Phase

ABN3 mix on Luna Omega 5 µm C18 250x4.6mm (Batch 2) using Agilent 1260 Binary UHPLC system

Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

26495

Reversed Phase

ABN3 mix on Luna Omega 5 µm C18 250x4.6mm (Batch 1) using Agilent 1260 Binary UHPLC system

Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea

26494

ABN3 mix on Waters XBridge 3.5 µm C18 150x4.6mm (Batch 3) using Agilent 1260 Binary UHPLC system

26493

ABN3 mix on Waters XBridge 3.5 µm C18 150x4.6mm (Batch 2) using Agilent 1260 Binary UHPLC system

26492

ABN3 mix on Waters XBridge 3.5 μm C18 150x4.6mm (Batch 1) using Agilent 1260 Binary UHPLC system

26491

ABN3 mix on Agilent Zorbax SB-C18 3.5 μm 150x4.6mm (Batch 3) using Agilent 1260 Binary UHPLC system

26490

ABN3 mix on Agilent Zorbax SB-C18 3.5 µm 150x4.6mm (Batch 2) using Agilent 1260 Binary UHPLC system

26489

ABN3 mix on Agilent Zorbax SB-C18 3.5 µm 150x4.6mm (Batch

  1. using Agilent 1260 Binary UHPLC system

26488

Reversed Phase

ABN3 mix on Luna Omega 3 µm C18 150x4.6mm (Batch 3) using Agilent 1260 Binary UHPLC system

Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

26487

Reversed Phase

ABN3 mix on Luna Omega 3 µm C18 150x4.6mm (Batch 2) using Agilent 1260 Binary UHPLC system

Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

26486

Reversed Phase

ABN3 mix on Luna Omega 3 µm C18 150x4.6mm (Batch 1) using Agilent 1260 Binary UHPLC system

Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

26485

ABN3 mix on Waters ACQUITY BEH 1.7 µm C18 (Batch 3) using Agilent 1260 Binary UHPLC system

26484

ABN3 mix on Waters ACQUITY BEH 1.7 µm C18 (Batch 2) using Agilent 1260 Binary UHPLC system

26483

ABN3 mix on Waters ACQUITY BEH 1.7 µm C18 (Batch 1) using Agilent 1260 Binary UHPLC system

26482

ABN3 mix on Agilent Zorbax RRHD SB-C18 1.8 µm C18 50x2.1mm (Batch 3) using Agilent 1260 Binary UHPLC system

26481

ABN3 mix on Agilent Zorbax RRHD SB-C18 1.8 µm C18 50x2.1mm (Batch 2) using Agilent 1260 Binary UHPLC system

26480

ABN3 mix on Agilent Zorbax RRHD SB-C18 1.8 µm C18 50x2.1mm (Batch 1) using Agilent 1260 Binary UHPLC system

26479

Reversed Phase

ABN3 mix on Luna Omega 1.6 µm C18 50x2.1mm (Batch 3) using Agilent 1260 Binary UHPLC system

Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA

26478

Reversed Phase

ABN3 mix on Luna Omega 1.6 µm C18 50x2.1mm (Batch 2) using Agilent 1260 Binary UHPLC system

Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA

26477

Reversed Phase

ABN3 mix on Luna Omega 1.6 µm C18 50x2.1mm (Batch 1) using Agilent 1260 Binary UHPLC system

Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA

26476

Reversed Phase

Fast Screening Method for 86 Forensic Analytes in Human Urine by LC-MS/MS

Luna 5 µm C18(2) 100 Å, LC Column 50 x 2 mm, Ea

25864

Reversed Phase

Tricyclic Antidepressants Panel by LC-MS/MS with Kinetex 2.6 um PS C18

Kinetex 2.6 µm PS C18 100 Å, LC Column 100 x 2.1 mm, Ea

25493

ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (7914) (Methanol)

25435

ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (Methanol)

25434

Reversed Phase

ABN7 in Formic Acid Screening on 2.6u Kinetex PS C18 50x4.6mm (0361) (Acetonitrile)

Kinetex 2.6 µm PS C18 100 Å, LC Column 50 x 4.6 mm, Ea

25424

ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (7914) (Acetonitrile)

25422

ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (7306) (Acetonitrile)

25417

Reversed Phase

TCAs on Luna Omega 3u PS C18 100x4.6mm

Luna Omega 3 µm PS C18 100 Å, LC Column 100 x 4.6 mm, Ea

24052

Reversed Phase

ABN7 on Luna Omega 1.6u PS C18 50x2.1mm

Luna Omega 1.6µm PS C18 100Å, LC Column 50 x 2.1 mm, EA

23707

Reversed Phase

7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea

23560

Reversed Phase

Fast Pain Panel ESI+

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea

23384

Reversed Phase

ABN6 Mix on Kinetex 1.7u EVO C18 50x2.1mm

Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea

23068

Reversed Phase

Batch Reproducibility with ABN 7 mix- Kinetex 2.6u F5 50x4.6mm

Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea

22803

Reversed Phase

TCAs at neutral pH Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22779

Reversed Phase

Analytical loading study using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22737

Reversed Phase

Batch reproducibility of Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22734

Reversed Phase

Pharma ABN Mixture using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22718

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 1.7u C18 100x2.1mm @ 0.60mL/min

Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20054

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6u C18 100x2.1mm @ 0.60mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20053

Reversed Phase

Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6 C18 100x2.1mm @ 1.0mL/min

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

20050

Reversed Phase

Pharma ABN Test 15 Mix on Un-Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20049

Reversed Phase

Pharma ABN Test 15 Mix on Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20048

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 2.6u C18 50x2.10mm @ 1.45mL/min 5min gradient

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20041

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 1.7u C18 50x2.10mm @ 1.0mL/min 5min gradient

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20040

Reversed Phase

Pharma ABN Test 15 Mix on Kinetex 2.6u C18 50x2.10mm @ 0.8mL/min 5 ming gradient

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20039

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 100 x 2.1mm @ 0.85 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea

19940

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 75 x 2.1mm @ 1.1 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 75 x 2.1 mm, Ea

19939

Reversed Phase

Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19911

Reversed Phase

Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19862

Reversed Phase

Pharmaceutical Mixture on Kinetex 2.6µm C8 50x2.1mm ID

Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea

19476

Reversed Phase

Pharmaceutical Mixture on Kinetex XB-C18

Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea

19475

Reversed Phase

Pharmaceutical Mixture on Kinetex C18

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19474

Reversed Phase

TCA's UV Kinetex 1.7µm C18 50x2.1mm Acquity UPLC

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19310

Reversed Phase

TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19309

Reversed Phase

TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19308

Reversed Phase

TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19307

Reversed Phase

TCA's LC/MS/MS Kinetex 1.7µm C18 50x2.1mm Agilent 1200

Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19306

Standard

Antidepressants (Underivatized) on ZB-1701, 15 m x 0.25 mm x 0.25 µm

Zebron ZB-1701, GC Cap. Column 15 m x 0.25 mm x 0.25 µm, Ea

19295

Reversed Phase

Competitor Comparison-Tricyclic Antideprassent on Kinetex 2.6 µm C18 100 x 4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

19230

Reversed Phase

MercuryMS - Luna 3µm C18(2) 20 x 2.0mm (mini column) for Tricyclics in Plasma by LC/MS/MS

Luna 3 µm C18(2) 100 Å, LC Column 20 x 2 mm, Ea

16043

MercuryMS - Synergi 2.5µm Fusion-RP 20 x 2.0mm for Tricyclics in Plasma by LC/MS/MS

16041