Naringenin on Lux Cellulose-1
LC Conditions
Column
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4459-E0
Phase Name
Cellulose-1
Elution Type
Isocratic
Mobile Phase
A: 0.1 % Formic acid in Hexane
B: 0.1% Formic acid in IPA
Gradient Profile
Step No.
Time(min)
%A
%B
1
20
60
40
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-1, 4 x 3.0mm, 10/Pk Part No.: AJ0-8403 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Naringenin
- 2. Naringenin
-OEChem-06211003142D<br><br> 32 34 0 1 0 0 0 0 0999 V2000<br> 6.8671 0.9254 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 -2.0746 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6155 -2.1092 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.3972 0.9495 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 2.4254 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 0.4254 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 6.0010 -0.5746 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 0.9254 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 -0.5746 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 -1.0746 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 0.4254 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6270 -1.1093 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6270 0.9601 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.4254 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 1.9254 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.5331 -0.5954 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.5331 0.4462 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 0.9254 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 2.4254 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 1.9254 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.1154 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3905 -0.4669 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7890 -1.1572 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6199 1.5800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -0.1946 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6720 2.2354 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.0688 -0.9075 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.6154 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 3.0454 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.1488 -2.4254 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.9353 0.6416 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 2.1154 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 6 1 0 0 0 0<br> 1 11 1 0 0 0 0<br> 2 10 2 0 0 0 0<br> 3 12 1 0 0 0 0<br> 3 30 1 0 0 0 0<br> 4 17 1 0 0 0 0<br> 4 31 1 0 0 0 0<br> 5 20 1 0 0 0 0<br> 5 32 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 8 1 0 0 0 0<br> 6 21 1 0 0 0 0<br> 7 10 1 0 0 0 0<br> 7 22 1 0 0 0 0<br> 7 23 1 0 0 0 0<br> 8 14 2 0 0 0 0<br> 8 15 1 0 0 0 0<br> 9 10 1 0 0 0 0<br> 9 11 1 0 0 0 0<br> 9 12 2 0 0 0 0<br> 11 13 2 0 0 0 0<br> 12 16 1 0 0 0 0<br> 13 17 1 0 0 0 0<br> 13 24 1 0 0 0 0<br> 14 18 1 0 0 0 0<br> 14 25 1 0 0 0 0<br> 15 19 2 0 0 0 0<br> 15 26 1 0 0 0 0<br> 16 17 2 0 0 0 0<br> 16 27 1 0 0 0 0<br> 18 20 2 0 0 0 0<br> 18 28 1 0 0 0 0<br> 19 20 1 0 0 0 0<br> 19 29 1 0 0 0 0<br>M END
Compound Name
Naringenin
CID
932
Molecular Formula
C15H12O5
Molecular Weight
272
No. Hydrogen Bond Acceptors
5
No. Hydrogen Bond Donors
3
Similar Applications
Chiral
Naringenin on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23339
Chiral
Naringenine on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21251
Chiral
Naringenine on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21250
Chiral
Naringenine on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21249
Chiral
Naringenine on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21248
Chiral
Naringenine on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21247
Chiral
Naringenine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21246
Chiral
Naringenine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21245
Chiral
Naringenine on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21244
Chiral
Naringenin on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20162
Chiral
Naringenin on Lux 5 µm Cellulose-1 by Chiral SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18962
Chiral
Naringenin on Lux 5 µm Cellulose-2 by Chiral SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
18961
Chiral
Naringenin on Lux 5 um Cellulose-1 w/Polarimeter Data
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18191
Chiral
Naringenin on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17314