Axia Packed Gemini-NX 5 µm C18 (high pH loading - Diphenhydramine and Propranolol - 10.4mg/400µL)

Axia Packed Gemini-NX 5 µm C18 (high pH loading - Diphenhydramine and Propranolol - 10.4mg/400µL)
LC Conditions
Column

Gemini 5 µm NX-C18 110 Å, LC Column 50 x 21.2 mm, AXIA Packed, Ea

Brand

Gemini

Part No

00B-4454-P0-AX

Phase Name

NX-C18

Elution Type

Gradient

Mobile Phase

A: 0.2 % NH4OH in Water

B: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

95

5

2

5

5

95

Flow Rate

30.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard PREP Cartridge, Gemini-NX C18 15 x 21.2mm, Ea Part No.: AJ0-8370 - Holder Part No.: AJ0-8223

Order Items Used in This Application

Gemini 5 µm NX-C18 110 Å, LC Column 50 x 21.2 mm, AXIA Packed, Ea
00B-4454-P0-AX

Gemini 5 µm NX-C18 110 Å, LC Column 50 x 21.2 mm, AXIA Packed, Ea

View Product

  • 1. Diphenhydramine
  • 2. Propranolol
-OEChem-06211003152D<br><br> 40 41  0     0  0  0  0  0  0999 V2000<br>    3.7320    0.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    2.7500    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    3.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    3.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1962    0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -2.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -3.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1962    1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.3700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3426    1.1423    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9441    1.8326    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2554    1.8577    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6540    1.1674    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1951   -1.4400    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301   -0.8700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010   -1.4400    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9272    1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3100    3.7869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4631    3.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.6900    2.7131    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0420    2.7131    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    3.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4220    3.7869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1951   -3.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7331   -0.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0010   -3.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    2.3700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -3.8700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7331    1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  3  1  0  0  0  0<br>  1  6  1  0  0  0  0<br>  2  7  1  0  0  0  0<br>  2 12  1  0  0  0  0<br>  2 13  1  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3 20  1  0  0  0  0<br>  4  8  2  0  0  0  0<br>  4 10  1  0  0  0  0<br>  5  9  2  0  0  0  0<br>  5 11  1  0  0  0  0<br>  6  7  1  0  0  0  0<br>  6 21  1  0  0  0  0<br>  6 22  1  0  0  0  0<br>  7 23  1  0  0  0  0<br>  7 24  1  0  0  0  0<br>  8 14  1  0  0  0  0<br>  8 25  1  0  0  0  0<br>  9 15  1  0  0  0  0<br>  9 26  1  0  0  0  0<br> 10 16  2  0  0  0  0<br> 10 27  1  0  0  0  0<br> 11 17  2  0  0  0  0<br> 11 28  1  0  0  0  0<br> 12 29  1  0  0  0  0<br> 12 30  1  0  0  0  0<br> 12 31  1  0  0  0  0<br> 13 32  1  0  0  0  0<br> 13 33  1  0  0  0  0<br> 13 34  1  0  0  0  0<br> 14 18  2  0  0  0  0<br> 14 35  1  0  0  0  0<br> 15 19  2  0  0  0  0<br> 15 36  1  0  0  0  0<br> 16 18  1  0  0  0  0<br> 16 37  1  0  0  0  0<br> 17 19  1  0  0  0  0<br> 17 38  1  0  0  0  0<br> 18 39  1  0  0  0  0<br> 19 40  1  0  0  0  0<br>M  END
Compound Name

Diphenhydramine

CID

3100

Molecular Formula

C17H21NO

Molecular Weight

255

No. Hydrogen Bond Acceptors

2

Similar Applications

Reversed Phase

Pill Screen on Verex and Whatman Filter Vials (Pill 1 - Benadryl)

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 100 x 4.6 mm, Ea

25593

Reversed Phase

Diphenhydramine in Water/Acetonitrile (50:50) Filtered vs Unfiltered Samples

Kinetex 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

25194

Reversed Phase

Cold Medications on Luna 3u Polar C18 100x4.6mm

Luna Omega 3 µm Polar C18 100 Å, LC Column 100 x 4.6 mm, Ea

24046

Reversed Phase

Cold medicine compounds on Kinetex 2.6 µm EVO C18

Kinetex 2.6 µm EVO C18 100 Å, LC Column 100 x 4.6 mm, EA

23036

Reversed Phase

Antihistamines on Kinetex 2.6u F5 50x4.6mm at pH 2.9 and pH 7.2

Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea

22838

Reversed Phase

ABN mix at low pH using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22735

Reversed Phase

ABN mix at high pH using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22733

Reversed Phase

ABN mix at neutral pH using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22732

Reversed Phase

Pharmaceutical drug mix using Kinetex 5u C18 100x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

20885

Reversed Phase

KNX 5 Brochure - Pharma mix analysis using Kinetex 5um C18 150x4.6mm

Kinetex 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

20738

Application Specific

Drug screen by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18175