Axia Packed Gemini-NX 5 µm C18 (high pH loading - Lidocaine and Diphenhydramine - 110mg/100µL)
LC Conditions
Column
Gemini 5 µm NX-C18 110 Å, LC Column 50 x 21.2 mm, AXIA Packed, Ea
Brand
Gemini
Part No
00B-4454-P0-AX
Phase Name
NX-C18
Elution Type
Gradient
Mobile Phase
A: 0.2 % NH4OH in Water
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
95
5
2
5
5
95
Flow Rate
30.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard PREP Cartridge, Gemini-NX C18 15 x 21.2mm, Ea Part No.: AJ0-8370 - Holder Part No.: AJ0-8223
Order Items Used in This Application
- 1. Lidocaine
- 2. Diphenhydramine
-OEChem-06211003152D<br><br> 39 39 0 0 0 0 0 0 0999 V2000<br> 5.4641 -0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.7500 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.2500 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3860 1.8326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9875 1.1423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2520 3.3326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8535 2.6423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9316 0.7751 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7287 0.7751 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6401 2.7131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8671 3.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0201 3.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5062 1.2131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 2.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8862 2.2869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7741 -1.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -0.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1541 -0.7131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -0.7131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -0.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 -1.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 8 2 0 0 0 0<br> 2 4 1 0 0 0 0<br> 2 5 1 0 0 0 0<br> 2 6 1 0 0 0 0<br> 3 7 1 0 0 0 0<br> 3 8 1 0 0 0 0<br> 3 24 1 0 0 0 0<br> 4 8 1 0 0 0 0<br> 4 18 1 0 0 0 0<br> 4 19 1 0 0 0 0<br> 5 11 1 0 0 0 0<br> 5 20 1 0 0 0 0<br> 5 21 1 0 0 0 0<br> 6 12 1 0 0 0 0<br> 6 22 1 0 0 0 0<br> 6 23 1 0 0 0 0<br> 7 9 2 0 0 0 0<br> 7 10 1 0 0 0 0<br> 9 13 1 0 0 0 0<br> 9 15 1 0 0 0 0<br> 10 14 2 0 0 0 0<br> 10 16 1 0 0 0 0<br> 11 25 1 0 0 0 0<br> 11 26 1 0 0 0 0<br> 11 27 1 0 0 0 0<br> 12 28 1 0 0 0 0<br> 12 29 1 0 0 0 0<br> 12 30 1 0 0 0 0<br> 13 17 2 0 0 0 0<br> 13 31 1 0 0 0 0<br> 14 17 1 0 0 0 0<br> 14 32 1 0 0 0 0<br> 15 33 1 0 0 0 0<br> 15 34 1 0 0 0 0<br> 15 35 1 0 0 0 0<br> 16 36 1 0 0 0 0<br> 16 37 1 0 0 0 0<br> 16 38 1 0 0 0 0<br> 17 39 1 0 0 0 0<br>M END
Compound Name
Lidocaine
CID
3676
Molecular Formula
C14H22N2O
Molecular Weight
234
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
1
Similar Applications
Application Specific
Local Anesthetics (Underivatized) on ZB-Drug-1, 10 m x 0.18 mm x 0.18 µm
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
19298
Application Specific
Drug screen by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18175
Drug Screen on Zebron ZB-1MS 12m x 0.20mm x 0.33um
15869
Standard
Drug Screen on Zebron ZB-5MS 20m x 0.18mm x 0.18um
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
15868
Drug Screen on Zebron ZB-1MS 20m x 0.18mm x 0.18um
15867