Chlormezanone on Lux 5µ Cellulose-1 250 x 4.6mm in PO-CH3CN

Chlormezanone on Lux 5µ Cellulose-1 250 x 4.6mm in PO-CH3CN
LC Conditions
Column

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

Brand

Lux

Part No

00G-4459-E0

Phase Name

Cellulose-1

Elution Type

Isocratic

Mobile Phase

A: 0.1 % DEA in CH3CN

B: 0.1% DEA in IPA

Gradient Profile

Step No.

Time(min)

%A

%B

1

10

95

5

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-1, 4 x 3.0mm, 10/Pk Part No.: AJ0-8403 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
00G-4459-E0

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

View Product

  • 1. Chlormezanone
  • 2. Chlormezanone
-OEChem-06211003152D<br><br> 29 30  0     1  0  0  0  0  0999 V2000<br>    2.0000   -2.2500    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301   -0.7500    0.0000 S   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.8301   -1.6160    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.8301   -1.6160    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    2.2500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    0.7500    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -0.2500    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    7.1962   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1962    0.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -0.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981   -1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -0.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -0.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -0.8700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.4082   -0.8326    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.8067   -0.1423    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.8067    0.6423    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.4082    1.3326    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9081    1.7869    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0611    1.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2881    0.7131    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -2.0600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.3700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.8700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291   -0.4400    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 17  1  0  0  0  0<br>  2  3  2  0  0  0  0<br>  2  4  2  0  0  0  0<br>  2  7  1  0  0  0  0<br>  2  8  1  0  0  0  0<br>  5 11  2  0  0  0  0<br>  6  7  1  0  0  0  0<br>  6 11  1  0  0  0  0<br>  6 12  1  0  0  0  0<br>  7 10  1  0  0  0  0<br>  7 18  1  0  0  0  0<br>  8  9  1  0  0  0  0<br>  8 19  1  0  0  0  0<br>  8 20  1  0  0  0  0<br>  9 11  1  0  0  0  0<br>  9 21  1  0  0  0  0<br>  9 22  1  0  0  0  0<br> 10 13  2  0  0  0  0<br> 10 14  1  0  0  0  0<br> 12 23  1  0  0  0  0<br> 12 24  1  0  0  0  0<br> 12 25  1  0  0  0  0<br> 13 15  1  0  0  0  0<br> 13 26  1  0  0  0  0<br> 14 16  2  0  0  0  0<br> 14 27  1  0  0  0  0<br> 15 17  2  0  0  0  0<br> 15 28  1  0  0  0  0<br> 16 17  1  0  0  0  0<br> 16 29  1  0  0  0  0<br>M  END
Compound Name

Chlormezanone

CID

2717

Molecular Formula

C11H12ClNO3S

Molecular Weight

273

No. Hydrogen Bond Acceptors

3

Similar Applications

Chiral

Lux i-Amylose-3 Separation for Chlormezanone

Lux 5 µm i-Amylose-3, LC Column 250 x 4.6 mm, Ea

25343

Chiral

Chlormezanone on Lux 5µm Cellulose-4 in NP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

20543

Chlormezanone on Lux 5µm Amylose-2 in NP

20528

Chiral

Chlormezanone on Lux 5µm Cellulose-2 in NP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

20505

Chiral

Chlormezanone on Lux 5µm Cellulose-1 in NP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

20485

Chiral

Chlormezanone on Lux 5µm Cellulose-3 in PO

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20371

Chiral

Chlormezanone on Lux 5µm Cellulose-3 in RP

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20332

Chiral

Chlormezanone on Lux 5µm Cellulose-3 in NP

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20108

Chiral

Chlormezanone on Lux 5µ Cellulose-1 250 x 4.6mm in PO-MeOH

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17730

Chiral

Chlormezanone on Lux 5µ Cellulose-1 250 x 4.6mm in PO-CH3CN

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17729

Chiral

Chlormezanone on Lux 5µ Cellulose-1 250 x 4.6mm in NP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17728

Chiral

Chlormezanone on Lux Cellulose-2

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

17410

Chiral

Chlormezanone on Lux Cellulose-1

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17409