Nitrogen and Phosphorous Pesticides (EPA 507) Mix # 1 on ZB-35

Nitrogen and Phosphorous Pesticides (EPA 507) Mix # 1 on ZB-35
GC Conditions
Column

Zebron ZB-35, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

Part No

7HG-G003-11

Phase Name

ZB-35

Injection

On-Column @ 43°C

Carrier Gas

Constant Flow Helium, 0.8 mL/min

Detection

Mass Selective (MSD) @ (335°C)

Detection Info
Sample Notes

Analytes 10 ppm in Acetone

Order Items Used in This Application

Zebron ZB-35, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
7HG-G003-11

Zebron ZB-35, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

View Product

  • 1. Cycloate
  • 2. Prometon
  • 3. Disulfoton
  • 4. Ametryn
  • 5. Fenamiphos
  • 6. Merphos
-OEChem-06211003152D<br><br> 35 35  0     0  0  0  0  0  0999 V2000<br>    3.7320    1.5000    0.0000 S   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    0.0000    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    0.0000    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320   -2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -3.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    0.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    2.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    3.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030   -0.6900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.7880   -0.9174    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.3894   -1.6077    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3426   -1.6077    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9441   -0.9174    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.3894   -2.3923    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.7880   -3.0826    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9441   -3.0826    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3426   -2.3923    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.4675   -3.4750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.2646   -3.4750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.3894    0.6077    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.7880   -0.0826    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6200    1.5000    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    2.1200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.3800    1.5000    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8101    1.4174    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2087    2.1077    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2181    3.0000    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    3.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9781    3.0000    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 11  1  0  0  0  0<br>  1 13  1  0  0  0  0<br>  2 11  2  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3 10  1  0  0  0  0<br>  3 11  1  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4  6  1  0  0  0  0<br>  4 15  1  0  0  0  0<br>  5  7  1  0  0  0  0<br>  5 16  1  0  0  0  0<br>  5 17  1  0  0  0  0<br>  6  8  1  0  0  0  0<br>  6 18  1  0  0  0  0<br>  6 19  1  0  0  0  0<br>  7  9  1  0  0  0  0<br>  7 20  1  0  0  0  0<br>  7 21  1  0  0  0  0<br>  8  9  1  0  0  0  0<br>  8 22  1  0  0  0  0<br>  8 23  1  0  0  0  0<br>  9 24  1  0  0  0  0<br>  9 25  1  0  0  0  0<br> 10 12  1  0  0  0  0<br> 10 26  1  0  0  0  0<br> 10 27  1  0  0  0  0<br> 12 28  1  0  0  0  0<br> 12 29  1  0  0  0  0<br> 12 30  1  0  0  0  0<br> 13 14  1  0  0  0  0<br> 13 31  1  0  0  0  0<br> 13 32  1  0  0  0  0<br> 14 33  1  0  0  0  0<br> 14 34  1  0  0  0  0<br> 14 35  1  0  0  0  0<br>M  END
Compound Name

Cycloate

CID

14337

Molecular Formula

C11H21NOS

Molecular Weight

215

No. Hydrogen Bond Acceptors

1

Similar Applications

Application Specific

EPA Method 525.2 on ZB-SemiVolatiles

Zebron ZB-SemiVolatiles, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

21438

Application Specific

Screening of Pesticides by GC-MS on ZB-MultiResidue-1

Zebron ZB-MultiResidue-1, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16184

Application Specific

Screening of Pesticide by GC/MS on ZB-MR2

Zebron ZB-MultiResidue-2, GC Cap. Column 30 m x 0.25 mm x 0.20 µm, Ea

16183

Standard

Nitrogen and Phosphorous Pesticides - EPA Method 507 on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15445

Standard

Nitrogen and Phosphorous Pesticides on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

15443

Standard

EPA Method 525.2: Organic compounds in Drinking Water on ZB-5 on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14771

Standard

Herbicides: EPA Method 8051

Zebron ZB-1701, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

1305