Ketamine on Lux 5µ Cellulose-2 in RP 60%CH3CN
LC Conditions
Column
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4457-E0
Phase Name
Cellulose-2
Elution Type
Isocratic
Mobile Phase
A: 20mM Ammonium acetate + 0.1%DEA
B: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
10
40
60
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-2, 4 x 3.0mm, 10/Pk Part No.: AJ0-8366 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Ketamine
- 2. Ketamine
-OEChem-06211003152D<br><br> 32 33 0 1 0 0 0 0 0999 V2000<br> 5.6114 -0.8192 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.1352 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2320 0.7308 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.1352 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.6352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.6352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.1352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.6352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.6352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4981 0.5076 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4378 0.1656 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3244 1.4924 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2320 0.7308 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2038 0.8084 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0905 2.1352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0302 1.7932 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2087 -0.7429 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8101 -0.0526 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8101 -2.2178 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2087 -1.5275 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3335 -2.6101 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1306 -2.6101 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2554 -1.5275 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6540 -2.2178 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3397 1.3414 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7418 1.7045 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2320 1.3508 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6120 0.7308 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2320 0.1108 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7864 0.5963 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9828 2.7458 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5051 2.1917 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 11 1 0 0 0 0<br> 2 8 2 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 13 1 0 0 0 0<br> 3 25 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 8 1 0 0 0 0<br> 4 10 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 17 1 0 0 0 0<br> 5 18 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 19 1 0 0 0 0<br> 6 20 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 21 1 0 0 0 0<br> 7 22 1 0 0 0 0<br> 8 9 1 0 0 0 0<br> 9 23 1 0 0 0 0<br> 9 24 1 0 0 0 0<br> 10 11 1 0 0 0 0<br> 10 12 2 0 0 0 0<br> 11 14 2 0 0 0 0<br> 12 15 1 0 0 0 0<br> 12 26 1 0 0 0 0<br> 13 27 1 0 0 0 0<br> 13 28 1 0 0 0 0<br> 13 29 1 0 0 0 0<br> 14 16 1 0 0 0 0<br> 14 30 1 0 0 0 0<br> 15 16 2 0 0 0 0<br> 15 31 1 0 0 0 0<br> 16 32 1 0 0 0 0<br>M END
Compound Name
Ketamine
CID
3821
Molecular Formula
C13H16ClNO
Molecular Weight
237
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
1
Similar Applications
Chiral
Norketamine on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20337
Chiral
Ketamine on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20287
Chiral
Norketamine on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20131
Chiral
Ketamine on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20112
RP Enantioseparation of Ketamine and Norketamine on Lux Amylose-2
19439
Chiral
Ketamine on Lux 5µ Cellulose-2 in RP 60%CH3CN
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
18527
Chiral
Ketamine on Lux 5µ Cellulose-2 in RP 40%CH3CN
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17857
Chiral
Ketamine on Lux 5µ Cellulose-2 in RP 30%CH3CN
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17856