Catecholamines on Kinetex 2.6 µm HILIC 50 x 4.6 mm Agilent 1200

Catecholamines on Kinetex 2.6 µm HILIC 50 x 4.6 mm Agilent 1200
LC Conditions
Column

Kinetex 2.6 µm HILIC 100 Å, LC Column 50 x 4.6 mm, Ea

Brand

Kinetex

Part No

00B-4461-E0

Phase Name

HILIC

Elution Type

Isocratic

Mobile Phase

A: 90/10 ACN/100mM NH4 formate pH 3.2

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

2.00 mL/min

Temperature

0°C

Detection

UV-Vis Abs.-Diode Array (PDA) @ (25°C)

Detection Info

Order Items Used in This Application

Kinetex 2.6 µm HILIC 100 Å, LC Column 50 x 4.6 mm, Ea
00B-4461-E0

Kinetex 2.6 µm HILIC 100 Å, LC Column 50 x 4.6 mm, Ea

View Product

  • 1. Serotonin
  • 2. Dopamine
  • 3. Epinephrine
  • 4. Norepinephrine
-OEChem-06211003152D<br><br> 25 26  0     0  0  0  0  0  0999 V2000<br>    2.5369    0.0103    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0812   -1.7944    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.6811    1.9223    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0812   -0.1850    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -0.4897    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3919    0.7656    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1350   -1.4897    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.6648   -0.9897    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.3704    0.9718    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.0103    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -1.9897    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030   -0.4897    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4030   -1.4897    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3713    1.3852    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.7781    0.8529    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.2848   -0.9897    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.2738   -2.3838    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.3910    0.3521    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.9842    0.8844    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690    0.6303    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2690   -2.6097    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660   -1.7997    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.2877    2.0502    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.2670    2.3838    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.2997    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 12  1  0  0  0  0<br>  1 25  1  0  0  0  0<br>  2  7  1  0  0  0  0<br>  2  8  1  0  0  0  0<br>  2 17  1  0  0  0  0<br>  3  9  1  0  0  0  0<br>  3 23  1  0  0  0  0<br>  3 24  1  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4  6  1  0  0  0  0<br>  4  8  2  0  0  0  0<br>  5  7  2  0  0  0  0<br>  5 10  1  0  0  0  0<br>  6  9  1  0  0  0  0<br>  6 14  1  0  0  0  0<br>  6 15  1  0  0  0  0<br>  7 11  1  0  0  0  0<br>  8 16  1  0  0  0  0<br>  9 18  1  0  0  0  0<br>  9 19  1  0  0  0  0<br> 10 12  2  0  0  0  0<br> 10 20  1  0  0  0  0<br> 11 13  2  0  0  0  0<br> 11 21  1  0  0  0  0<br> 12 13  1  0  0  0  0<br> 13 22  1  0  0  0  0<br>M  END
Compound Name

Serotonin

CID

5202

Molecular Formula

C10H12N2O

Molecular Weight

176

No. Hydrogen Bond Acceptors

2

No. Hydrogen Bond Donors

3

Similar Applications

Hydrophilic Interaction

HILIC Separation of Catecholamines

Luna Omega 3µm HILIC 100Å, LC Column 150 x 4.6 mm, ea

28692

Reversed Phase

Catecholamines on Micro Kinetex C18

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 0.3 mm, Capillary, Ea

26421

Reversed Phase

Catecholamines- Micro Kinetex F5

Kinetex 2.6 µm F5 100 Å, LC Column 50 x 0.3 mm, Ea

26420

Hydrophilic Interaction

Neurotransmitters on Luna 3 µm HILIC 100 x 2.0 mm

Luna 3 µm HILIC 200 Å, LC Column 100 x 2 mm, Ea

19055

Hydrophilic Interaction

Catecholamines on Kinetex 2.6 µm HILIC 50 x 4.6 mm Agilent 1200

Kinetex 2.6 µm HILIC 100 Å, LC Column 50 x 4.6 mm, Ea

18890

Reversed Phase

Catecholamines on Kinetex 2.6µm PFP 150 x 4.6mm ID ( in ammonium formate buffer)

Kinetex 2.6 µm PFP 100 Å, LC Column 150 x 4.6 mm, Ea

18705

Reversed Phase

Catecholamines on Kinetex 2.6µm C18 150 x 4.6mm ID ( in ammonium formate buffer)

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

18704

Reversed Phase

Catecholamines on Kinetex 2.6µm PFP 150 x 4.6mm ID

Kinetex 2.6 µm PFP 100 Å, LC Column 150 x 4.6 mm, Ea

18688

Reversed Phase

Catecholamines on Kinetex 2.6µm C18 150 x 4.6mm ID

Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

18687

Reversed Phase

Catecholamines on Kinetex 2.6µm PFP 50 x 2.1mm ID by LCMS

Kinetex 2.6 µm PFP 100 Å, LC Column 50 x 2.1 mm, Ea

18648

Reversed Phase

Catecholamines using Synergi Fusion-RP

Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea

15738

Reversed Phase

Catecholamines on Prodigy 5 ODS (3)

Prodigy 5 µm ODS-3 100 Å, LC Column 150 x 4.6 mm, Ea

10106

Catecholamines on Prodigy 5 ODS (2)

10105

Reversed Phase

Catecholamines - Sphereclone vs. Spherisorb Comparison

SphereClone 5 µm C6 80 Å, LC Column 250 x 4.6 mm, Ea

5582

Catecholamines

5502

Reversed Phase

Catecholamines

Luna 5 µm C8 100 Å, LC Column 150 x 4.6 mm, Ea

1189

Reversed Phase

Catecholamines

Aqua 5 µm C18 125 Å, LC Column 150 x 4.6 mm, Ea

1167

Reversed Phase

Catecholamines

Luna 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

1165

Reversed Phase

Catecholamines

Luna 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea

1151