Catecholamines on Kinetex 2.6 µm HILIC 50 x 4.6 mm Agilent 1200
LC Conditions
Column
Kinetex 2.6 µm HILIC 100 Å, LC Column 50 x 4.6 mm, Ea
Brand
Kinetex
Part No
00B-4461-E0
Phase Name
HILIC
Elution Type
Isocratic
Mobile Phase
A: 90/10 ACN/100mM NH4 formate pH 3.2
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
2.00 mL/min
Temperature
0°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (25°C)
Detection Info
Order Items Used in This Application
- 1. Serotonin
- 2. Dopamine
- 3. Epinephrine
- 4. Norepinephrine
-OEChem-06211003152D<br><br> 25 26 0 0 0 0 0 0 0999 V2000<br> 2.5369 0.0103 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0812 -1.7944 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6811 1.9223 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0812 -0.1850 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -0.4897 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3919 0.7656 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -1.4897 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6648 -0.9897 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3704 0.9718 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.0103 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.9897 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -0.4897 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -1.4897 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3713 1.3852 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7781 0.8529 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2848 -0.9897 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2738 -2.3838 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3910 0.3521 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9842 0.8844 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.6303 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -2.6097 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.7997 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.2877 2.0502 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2670 2.3838 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.2997 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 12 1 0 0 0 0<br> 1 25 1 0 0 0 0<br> 2 7 1 0 0 0 0<br> 2 8 1 0 0 0 0<br> 2 17 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 3 23 1 0 0 0 0<br> 3 24 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 8 2 0 0 0 0<br> 5 7 2 0 0 0 0<br> 5 10 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 14 1 0 0 0 0<br> 6 15 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 8 16 1 0 0 0 0<br> 9 18 1 0 0 0 0<br> 9 19 1 0 0 0 0<br> 10 12 2 0 0 0 0<br> 10 20 1 0 0 0 0<br> 11 13 2 0 0 0 0<br> 11 21 1 0 0 0 0<br> 12 13 1 0 0 0 0<br> 13 22 1 0 0 0 0<br>M END
Compound Name
Serotonin
CID
5202
Molecular Formula
C10H12N2O
Molecular Weight
176
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
3
Similar Applications
Hydrophilic Interaction
HILIC Separation of Catecholamines
Luna Omega 3µm HILIC 100Å, LC Column 150 x 4.6 mm, ea
28692
Reversed Phase
Catecholamines on Micro Kinetex C18
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 0.3 mm, Capillary, Ea
26421
Reversed Phase
Catecholamines- Micro Kinetex F5
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 0.3 mm, Ea
26420
Hydrophilic Interaction
Neurotransmitters on Luna 3 µm HILIC 100 x 2.0 mm
Luna 3 µm HILIC 200 Å, LC Column 100 x 2 mm, Ea
19055
Hydrophilic Interaction
Catecholamines on Kinetex 2.6 µm HILIC 50 x 4.6 mm Agilent 1200
Kinetex 2.6 µm HILIC 100 Å, LC Column 50 x 4.6 mm, Ea
18890
Reversed Phase
Catecholamines on Kinetex 2.6µm PFP 150 x 4.6mm ID ( in ammonium formate buffer)
Kinetex 2.6 µm PFP 100 Å, LC Column 150 x 4.6 mm, Ea
18705
Reversed Phase
Catecholamines on Kinetex 2.6µm C18 150 x 4.6mm ID ( in ammonium formate buffer)
Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
18704
Reversed Phase
Catecholamines on Kinetex 2.6µm PFP 150 x 4.6mm ID
Kinetex 2.6 µm PFP 100 Å, LC Column 150 x 4.6 mm, Ea
18688
Reversed Phase
Catecholamines on Kinetex 2.6µm C18 150 x 4.6mm ID
Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
18687
Reversed Phase
Catecholamines on Kinetex 2.6µm PFP 50 x 2.1mm ID by LCMS
Kinetex 2.6 µm PFP 100 Å, LC Column 50 x 2.1 mm, Ea
18648
Reversed Phase
Catecholamines using Synergi Fusion-RP
Synergi 4 µm Fusion-RP 80 Å, LC Column 150 x 4.6 mm, Ea
15738
Reversed Phase
Catecholamines on Prodigy 5 ODS (3)
Prodigy 5 µm ODS-3 100 Å, LC Column 150 x 4.6 mm, Ea
10106
Catecholamines on Prodigy 5 ODS (2)
10105
Reversed Phase
Catecholamines - Sphereclone vs. Spherisorb Comparison
SphereClone 5 µm C6 80 Å, LC Column 250 x 4.6 mm, Ea
5582
Catecholamines
5502
Reversed Phase
Catecholamines
Luna 5 µm C8 100 Å, LC Column 150 x 4.6 mm, Ea
1189
Reversed Phase
Catecholamines
Aqua 5 µm C18 125 Å, LC Column 150 x 4.6 mm, Ea
1167
Reversed Phase
Catecholamines
Luna 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
1165
Reversed Phase
Catecholamines
Luna 5 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
1151