Corticosteroids Analysis on Luna 5u CN 150 x 4.6mm ID

Corticosteroids Analysis on Luna 5u CN 150 x 4.6mm ID
LC Conditions
Column

Luna 5 µm CN 100 Å, LC Column 150 x 4.6 mm, Ea

Brand

Luna

Part No

00F-4255-E0

Phase Name

CN

Elution Type

Isocratic

Mobile Phase

A: Hexane

B: 80:20 Methylene Chloride/Methanol

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

80

20

Flow Rate

2.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, CN 4 x 3.0mm ID, 10/Pk Part No.: AJ0-4305 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Luna 5 µm CN 100 Å, LC Column 150 x 4.6 mm, Ea
00F-4255-E0

Luna 5 µm CN 100 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Testosterone
  • 2. Cortisone acetate
  • 3. Corticosterone
  • 4. Cortisone
  • 5. Prednisolone
-OEChem-06211003152D<br><br> 49 52  0     1  0  0  0  0  0999 V2000<br>    8.6500    2.1128    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -2.1948    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.3931   -0.1425    0.0000 C   0  0  2  0  0  0  0  0  0  0  0  0<br>    7.3931    0.8575    0.0000 C   0  0  2  0  0  0  0  0  0  0  0  0<br>    6.5271   -0.6425    0.0000 C   0  0  1  0  0  0  0  0  0  0  0  0<br>    5.6610   -0.1425    0.0000 C   0  0  1  0  0  0  0  0  0  0  0  0<br>    4.7510   -0.6493    0.0000 C   0  0  2  0  0  0  0  0  0  0  0  0<br>    6.5271    1.3575    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6610    0.8575    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.3393    1.1623    0.0000 C   0  0  2  0  0  0  0  0  0  0  0  0<br>    8.3393   -0.4472    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5431   -1.6840    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.9229    0.3575    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7430   -1.6909    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6451   -2.2117    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.3931    1.8575    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8242   -0.0852    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7587    0.3507    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8763   -0.6132    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8076   -2.2406    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8680   -1.6981    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.4830   -0.9877    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.2664   -1.0618    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3972    0.2825    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.9256    1.8325    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.1285    1.8325    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4490    1.4401    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.0504    0.7499    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.9018    1.6016    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.0883   -1.0141    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.8767   -0.7564    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.7612   -2.2644    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1523   -1.5685    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    9.3838   -0.0572    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    9.3838    0.7723    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.2478   -2.6877    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0460   -2.6846    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.0131    1.8575    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.3931    2.4775    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.7731    1.8575    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2324    0.3814    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4343    0.3968    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3787    0.3459    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7635    0.9706    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.1388    0.3554    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6718   -0.0279    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2647   -0.7146    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8100   -2.8606    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    9.2566    2.2406    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br> 10  1  1  1  0  0  0<br>  1 49  1  0  0  0  0<br>  2 21  2  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3  5  1  0  0  0  0<br>  3 11  1  0  0  0  0<br>  3 22  1  6  0  0  0<br>  4  8  1  0  0  0  0<br>  4 10  1  0  0  0  0<br>  4 16  1  1  0  0  0<br>  5  6  1  0  0  0  0<br>  5 12  1  0  0  0  0<br>  5 23  1  1  0  0  0<br>  6  7  1  0  0  0  0<br>  6  9  1  0  0  0  0<br>  6 24  1  6  0  0  0<br>  7 14  1  0  0  0  0<br>  7 17  1  0  0  0  0<br>  7 18  1  1  0  0  0<br>  8  9  1  0  0  0  0<br>  8 25  1  0  0  0  0<br>  8 26  1  0  0  0  0<br>  9 27  1  0  0  0  0<br>  9 28  1  0  0  0  0<br> 10 13  1  0  0  0  0<br> 10 29  1  0  0  0  0<br> 11 13  1  0  0  0  0<br> 11 30  1  0  0  0  0<br> 11 31  1  0  0  0  0<br> 12 15  1  0  0  0  0<br> 12 32  1  0  0  0  0<br> 12 33  1  0  0  0  0<br> 13 34  1  0  0  0  0<br> 13 35  1  0  0  0  0<br> 14 15  1  0  0  0  0<br> 14 20  2  0  0  0  0<br> 15 36  1  0  0  0  0<br> 15 37  1  0  0  0  0<br> 16 38  1  0  0  0  0<br> 16 39  1  0  0  0  0<br> 16 40  1  0  0  0  0<br> 17 19  1  0  0  0  0<br> 17 41  1  0  0  0  0<br> 17 42  1  0  0  0  0<br> 18 43  1  0  0  0  0<br> 18 44  1  0  0  0  0<br> 18 45  1  0  0  0  0<br> 19 21  1  0  0  0  0<br> 19 46  1  0  0  0  0<br> 19 47  1  0  0  0  0<br> 20 21  1  0  0  0  0<br> 20 48  1  0  0  0  0<br>M  END
Compound Name

Testosterone

CID

6013

Molecular Formula

C19H28O2

Molecular Weight

288

No. Hydrogen Bond Acceptors

2

No. Hydrogen Bond Donors

1

Similar Applications

Reversed Phase

Neat Standard Steroid Screen on Kinetex 5um Biphenyl 50 *4.6mm

Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 4.6 mm, Ea

26358

Reversed Phase

Steroids Screen - Micro Kinetex Biphenyl

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 0.3 mm, Capillary, Ea

26353

Reversed Phase

Steroids Screen - Micro Kinetex F5

Kinetex 2.6 µm F5 100 Å, LC Column 50 x 0.3 mm, Ea

26352

Reversed Phase

Steroids Screen Micro Kinetex XB C18

Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 0.3 mm, microflow, Ea

26351

Reversed Phase

Steroids Screen on a Microflow Kinetex 2.6 µm C18 50 x .3 mm Column

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 0.3 mm, Capillary, Ea

26350

Reversed Phase

80 pg/mL Testosterone in Plasma using Novum PRO and a Kinetex 1.7 µm Biphenyl 50 x 2.1 mm

Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

26240

Reversed Phase

20 pg/mL Testosterone from Plasma Using Novum PRO SLE and a Kinetex 1.7 µm Biphenyl 50 x 2.1 mm

Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

26239

Reversed Phase

10 pg/mL Testosterone (LLOQ) from Plasma Using Novum PRO SLE and a Kinetex 1.7 µm Biphenyl 50 x 2.1mm

Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

26238

Reversed Phase

Solvent Blank on Kinetex 1.7 μm Biphenyl 50 x 2.1mm

Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

26237

Reversed Phase

Plasma Blank on Kinetex 1.7 μm Biphenyl 50 x 2.1mm

Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

26236

Reversed Phase

Testosterone Calibration Curve on Kinetex 1.7 μm Biphenyl 50 x 2.1mm

Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

26235

Reversed Phase

EPA 539 using Kinetex 5u EVO C18 100x3.0mm

Kinetex 5 µm EVO C18 100 Å, LC Column 100 x 3.0 mm, Ea

22780

Reversed Phase

Testosterone-Oxime on Gemini-NX C18, 3um, 50x2 mm

Gemini 3 µm NX-C18 110 Å, LC Column 50 x 2 mm, Ea

20844

Reversed Phase

Steroid panel by LCMS using Kinetex 2.6u C18 100x3.0mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 3 mm, Ea

20655

Reversed Phase

Testosterone and 17-OH-Progesterone by LCMS using Gemini NX 3u C18 50x2.1mm

Gemini 3 µm NX-C18 110 Å, LC Column 50 x 2 mm, Ea

20652

Reversed Phase

Testosterone from Female Human Plasma by LC/MS/MS using Strata-X-A and Kinetex 1.7 µm C18

Kinetex 1.7 µm C18 100 Å, LC Column 30 x 2.1 mm, Ea

19762

Reversed Phase

Separation of Testosterone and Epitestosterone by LC/MS/MS using Strata-X-A and Kinetex 1.7 µm C18

Kinetex 1.7 µm C18 100 Å, LC Column 30 x 2.1 mm, Ea

19761

Reversed Phase

Testosterone from Male Human Plasma by LC/MS/MS using Strata-X-A and Kinetex 1.7 µm C18

Kinetex 1.7 µm C18 100 Å, LC Column 30 x 2.1 mm, Ea

19760

Sex hormones on a ZB-1ms 30x0.25x0.25 by GCMS

19293

Normal Phase

Corticosteroids Analysis on Luna 5u CN 150 x 4.6mm ID

Luna 5 µm CN 100 Å, LC Column 150 x 4.6 mm, Ea

18919

Reversed Phase

Extraction of Steroids Using Strata-X on Kinetex 2.6µm C18 50 x 2.1mm ID by LCMS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

18848

Reversed Phase

LC-MS-MS Analysis of Testosterone on Gemini C18, 5u, 50x2.0 Column

Gemini 5 µm C18 110 Å, LC Column 50 x 2 mm, Ea

18463

Reversed Phase

Testosterone on Synergi Max-RP (75 x 3mm)

Synergi 4 µm Max-RP 80 Å, LC Column 75 x 3 mm, Ea

18292

Hormones/Steroids by MSD on a ZB-5MSi

17935

Application Specific

Hormones/Steroids by MSD on a ZB-Drug-1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

17934

Reversed Phase

Extraction of Testosterone from Human plasma using strata-X on Gemini C18

Gemini 5 µm C18 110 Å, LC Column 50 x 2 mm, Ea

17473

Reversed Phase

Steroids on Onyx C18

Onyx Monolithic C18, LC Column 50 x 4.6 mm, Ea

15477

Reversed Phase

USP Progesterone Injection on Bondclone C18

Bondclone 10 µm C18 148 Å, LC Column 300 x 3.9 mm, Ea

14308