Tricyclic Antidepressants Analysis on Luna 5u C8(2) 150 x 4.6mm ID
LC Conditions
Column
Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea
Brand
Luna
Part No
00F-4249-E0
Phase Name
C8(2)
Elution Type
Isocratic
Mobile Phase
A: 20Mm Phosphate Buffer pH=7.0
B: Methanol
C: Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
50
35
Flow Rate
1.20 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C8 4 x 3.0mm ID, 10/Pk Part No.: AJ0-4290 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Protriptyline
- 2. Desipramine
- 3. Nortriptyline
- 4. Imipramine
- 5. Amitriptyline
-OEChem-06211003152D<br><br> 41 43 0 0 0 0 0 0 0999 V2000<br> 3.1509 -2.0953 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8830 0.9047 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8830 -0.0953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9820 1.3386 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7840 1.3385 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0170 -0.5953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7595 2.3135 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0065 2.3135 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0169 -1.5953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2295 0.6184 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5365 0.6184 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3830 3.0953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3830 3.0953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.7690 2.6358 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9970 2.6358 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2318 0.9177 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5342 0.9177 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 1.9333 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7660 1.9332 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1509 -3.0953 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4080 0.5748 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0950 -0.6779 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4936 0.0123 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8049 -0.0127 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4064 -0.7030 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2290 -2.1779 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6275 -1.4877 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3744 0.0156 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3916 0.0155 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1140 3.6539 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6520 3.6539 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6380 3.2418 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1280 3.2418 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7789 0.4943 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9871 0.4942 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6140 -1.7853 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4083 2.1183 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.3578 2.1182 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5309 -3.0953 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1509 -3.7153 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7709 -3.0953 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 9 1 0 0 0 0<br> 1 20 1 0 0 0 0<br> 1 36 1 0 0 0 0<br> 2 3 1 0 0 0 0<br> 2 4 1 0 0 0 0<br> 2 5 1 0 0 0 0<br> 2 21 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 22 1 0 0 0 0<br> 3 23 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 10 2 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 11 2 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 24 1 0 0 0 0<br> 6 25 1 0 0 0 0<br> 7 12 1 0 0 0 0<br> 7 14 2 0 0 0 0<br> 8 13 1 0 0 0 0<br> 8 15 2 0 0 0 0<br> 9 26 1 0 0 0 0<br> 9 27 1 0 0 0 0<br> 10 16 1 0 0 0 0<br> 10 28 1 0 0 0 0<br> 11 17 1 0 0 0 0<br> 11 29 1 0 0 0 0<br> 12 13 2 0 0 0 0<br> 12 30 1 0 0 0 0<br> 13 31 1 0 0 0 0<br> 14 18 1 0 0 0 0<br> 14 32 1 0 0 0 0<br> 15 19 1 0 0 0 0<br> 15 33 1 0 0 0 0<br> 16 18 2 0 0 0 0<br> 16 34 1 0 0 0 0<br> 17 19 2 0 0 0 0<br> 17 35 1 0 0 0 0<br> 18 37 1 0 0 0 0<br> 19 38 1 0 0 0 0<br> 20 39 1 0 0 0 0<br> 20 40 1 0 0 0 0<br> 20 41 1 0 0 0 0<br>M END
Compound Name
Protriptyline
CID
4976
Molecular Formula
C19H21N
Molecular Weight
263
No. Hydrogen Bond Acceptors
1
No. Hydrogen Bond Donors
1
Similar Applications
Reversed Phase
Fast Screening Method for 86 Forensic Analytes in Human Urine by LC-MS/MS
Luna 5 µm C18(2) 100 Å, LC Column 50 x 2 mm, Ea
25864
Reversed Phase
Tricyclic Antidepressants Panel by LC-MS/MS with Kinetex 2.6 um PS C18
Kinetex 2.6 µm PS C18 100 Å, LC Column 100 x 2.1 mm, Ea
25493
Reversed Phase
Batch reproducibility of Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23070
Reversed Phase
Mix of Analytes on Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
22999
Reversed Phase
Mix of Analytes on Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22998
Reversed Phase
TCAs at neutral pH Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22779
Reversed Phase
Competitor Comparison-Tricyclic Antideprassent on Kinetex 2.6 µm C18 100 x 4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
19230