Tricyclic Antidepressants Analysis on Luna 5u C8(2) 150 x 4.6mm ID

Tricyclic Antidepressants Analysis on Luna 5u C8(2) 150 x 4.6mm ID
LC Conditions
Column

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea

Brand

Luna

Part No

00F-4249-E0

Phase Name

C8(2)

Elution Type

Isocratic

Mobile Phase

A: 20Mm Phosphate Buffer pH=7.0

B: Methanol

C: Acetonitrile

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

50

35

Flow Rate

1.20 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, C8 4 x 3.0mm ID, 10/Pk Part No.: AJ0-4290 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea
00F-4249-E0

Luna 5 µm C8(2) 100 Å, LC Column 150 x 4.6 mm, Ea

View Product

  • 1. Protriptyline
  • 2. Desipramine
  • 3. Nortriptyline
  • 4. Imipramine
  • 5. Amitriptyline
-OEChem-06211003152D<br><br> 41 43  0     0  0  0  0  0  0999 V2000<br>    3.1509   -2.0953    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8830    0.9047    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.8830   -0.0953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9820    1.3386    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.7840    1.3385    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0170   -0.5953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7595    2.3135    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0065    2.3135    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.0169   -1.5953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.2295    0.6184    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5365    0.6184    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.3830    3.0953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3830    3.0953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.7690    2.6358    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.9970    2.6358    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2318    0.9177    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.5342    0.9177    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    1.9333    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7660    1.9332    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1509   -3.0953    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4080    0.5748    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.0950   -0.6779    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4936    0.0123    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8049   -0.0127    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4064   -0.7030    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2290   -2.1779    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6275   -1.4877    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.3744    0.0156    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3916    0.0155    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.1140    3.6539    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6520    3.6539    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6380    3.2418    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1280    3.2418    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.7789    0.4943    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.9871    0.4942    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.6140   -1.7853    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4083    2.1183    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.3578    2.1182    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5309   -3.0953    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1509   -3.7153    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7709   -3.0953    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  9  1  0  0  0  0<br>  1 20  1  0  0  0  0<br>  1 36  1  0  0  0  0<br>  2  3  1  0  0  0  0<br>  2  4  1  0  0  0  0<br>  2  5  1  0  0  0  0<br>  2 21  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3 22  1  0  0  0  0<br>  3 23  1  0  0  0  0<br>  4  7  1  0  0  0  0<br>  4 10  2  0  0  0  0<br>  5  8  1  0  0  0  0<br>  5 11  2  0  0  0  0<br>  6  9  1  0  0  0  0<br>  6 24  1  0  0  0  0<br>  6 25  1  0  0  0  0<br>  7 12  1  0  0  0  0<br>  7 14  2  0  0  0  0<br>  8 13  1  0  0  0  0<br>  8 15  2  0  0  0  0<br>  9 26  1  0  0  0  0<br>  9 27  1  0  0  0  0<br> 10 16  1  0  0  0  0<br> 10 28  1  0  0  0  0<br> 11 17  1  0  0  0  0<br> 11 29  1  0  0  0  0<br> 12 13  2  0  0  0  0<br> 12 30  1  0  0  0  0<br> 13 31  1  0  0  0  0<br> 14 18  1  0  0  0  0<br> 14 32  1  0  0  0  0<br> 15 19  1  0  0  0  0<br> 15 33  1  0  0  0  0<br> 16 18  2  0  0  0  0<br> 16 34  1  0  0  0  0<br> 17 19  2  0  0  0  0<br> 17 35  1  0  0  0  0<br> 18 37  1  0  0  0  0<br> 19 38  1  0  0  0  0<br> 20 39  1  0  0  0  0<br> 20 40  1  0  0  0  0<br> 20 41  1  0  0  0  0<br>M  END
Compound Name

Protriptyline

CID

4976

Molecular Formula

C19H21N

Molecular Weight

263

No. Hydrogen Bond Acceptors

1

No. Hydrogen Bond Donors

1

Similar Applications

Reversed Phase

Fast Screening Method for 86 Forensic Analytes in Human Urine by LC-MS/MS

Luna 5 µm C18(2) 100 Å, LC Column 50 x 2 mm, Ea

25864

Reversed Phase

Tricyclic Antidepressants Panel by LC-MS/MS with Kinetex 2.6 um PS C18

Kinetex 2.6 µm PS C18 100 Å, LC Column 100 x 2.1 mm, Ea

25493

Reversed Phase

Batch reproducibility of Kinetex 1.7u EVO C18 50x2.1mm

Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea

23070

Reversed Phase

Mix of Analytes on Kinetex 1.7u EVO C18 50x2.1mm

Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea

22999

Reversed Phase

Mix of Analytes on Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22998

Reversed Phase

TCAs at neutral pH Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22779

Reversed Phase

Competitor Comparison-Tricyclic Antideprassent on Kinetex 2.6 µm C18 100 x 4.6mm

Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea

19230