Terfendadine on Luna HILIC 5 µm by SFC
LC Conditions
Column
Luna 5 µm HILIC 200 Å, LC Column 250 x 4.6 mm, Ea
Brand
Luna
Part No
00G-4450-E0
Phase Name
HILIC
Elution Type
Gradient
Mobile Phase
A: Methanol with 0.1% DEA
B: Carbon Dioxide
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
10
90
2
2
10
90
3
12
40
60
4
14
40
60
5
15
10
90
Flow Rate
3.00 mL/min
Temperature
35°C
Detection
UV-Vis Abs.-Fixed Wave. (UV) @ (35°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Silica 4 x 3.0mm, 10/Pk Part No.: AJ0-4348 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Terfenadine
-OEChem-06211003152D<br><br> 76 79 0 1 0 0 0 0 0999 V2000<br> 4.1350 4.0000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -1.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 1.0000 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 3.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 4.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 0.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 5.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.1350 4.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 5.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6350 3.1340 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 5.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6350 4.8660 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -2.0000 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 6.0010 6.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6350 3.1340 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 6.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6350 4.8660 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -3.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 7.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1350 4.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -6.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -5.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -3.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -3.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -4.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -4.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -7.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4030 -6.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4030 -6.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6720 3.3100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6116 2.3923 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2131 3.0826 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0569 3.0826 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6584 2.3923 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2131 0.9174 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6116 1.6077 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6584 1.6077 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0569 0.9174 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3471 -0.5826 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7456 0.1077 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0569 0.0826 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6584 -0.6077 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.8250 4.5369 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4810 -2.0826 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8796 -1.3923 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5380 5.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3250 2.5970 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 5.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3250 5.4030 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -1.1500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5380 6.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9450 2.5970 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 6.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.9450 5.4030 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 7.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.7550 4.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8059 -3.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -3.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8059 -4.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -4.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.7830 -7.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -7.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0230 -7.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4030 -5.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7830 -6.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.4030 -6.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4030 -6.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0230 -6.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4030 -5.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 7 1 0 0 0 0<br> 1 49 1 0 0 0 0<br> 2 19 1 0 0 0 0<br> 2 65 1 0 0 0 0<br> 3 8 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 3 10 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 36 1 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 37 1 0 0 0 0<br> 5 38 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 39 1 0 0 0 0<br> 6 40 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 7 12 1 0 0 0 0<br> 8 41 1 0 0 0 0<br> 8 42 1 0 0 0 0<br> 9 43 1 0 0 0 0<br> 9 44 1 0 0 0 0<br> 10 13 1 0 0 0 0<br> 10 45 1 0 0 0 0<br> 10 46 1 0 0 0 0<br> 11 15 2 0 0 0 0<br> 11 17 1 0 0 0 0<br> 12 16 2 0 0 0 0<br> 12 18 1 0 0 0 0<br> 13 14 1 0 0 0 0<br> 13 47 1 0 0 0 0<br> 13 48 1 0 0 0 0<br> 14 19 1 0 0 0 0<br> 14 50 1 0 0 0 0<br> 14 51 1 0 0 0 0<br> 15 20 1 0 0 0 0<br> 15 52 1 0 0 0 0<br> 16 21 1 0 0 0 0<br> 16 53 1 0 0 0 0<br> 17 22 2 0 0 0 0<br> 17 54 1 0 0 0 0<br> 18 23 2 0 0 0 0<br> 18 55 1 0 0 0 0<br> 19 24 1 0 0 0 0<br> 19 56 1 0 0 0 0<br> 20 25 2 0 0 0 0<br> 20 57 1 0 0 0 0<br> 21 26 2 0 0 0 0<br> 21 58 1 0 0 0 0<br> 22 25 1 0 0 0 0<br> 22 59 1 0 0 0 0<br> 23 26 1 0 0 0 0<br> 23 60 1 0 0 0 0<br> 24 29 2 0 0 0 0<br> 24 30 1 0 0 0 0<br> 25 61 1 0 0 0 0<br> 26 62 1 0 0 0 0<br> 27 28 1 0 0 0 0<br> 27 33 1 0 0 0 0<br> 27 34 1 0 0 0 0<br> 27 35 1 0 0 0 0<br> 28 31 2 0 0 0 0<br> 28 32 1 0 0 0 0<br> 29 31 1 0 0 0 0<br> 29 63 1 0 0 0 0<br> 30 32 2 0 0 0 0<br> 30 64 1 0 0 0 0<br> 31 66 1 0 0 0 0<br> 32 67 1 0 0 0 0<br> 33 68 1 0 0 0 0<br> 33 69 1 0 0 0 0<br> 33 70 1 0 0 0 0<br> 34 71 1 0 0 0 0<br> 34 72 1 0 0 0 0<br> 34 73 1 0 0 0 0<br> 35 74 1 0 0 0 0<br> 35 75 1 0 0 0 0<br> 35 76 1 0 0 0 0<br>M END
Compound Name
Terfenadine
CID
5405
Molecular Formula
C32H41NO2
Molecular Weight
471
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
2
Similar Applications
Reversed Phase
Kinetex 2.6u C18 100A and LC Column 150 x 0.3 mm- Pharma Screen
Kinetex 2.6 µm C18 100 Å, LC Column 150 x 0.3 mm, Capillary, Ea
26400
Reversed Phase
Kinetex 2.6u C18 100A, LC Column 50 x 0.3 mm- Pharma Screen
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 0.3 mm, Capillary, Ea
26399
Reversed Phase
Kinetex 2.6u XB-C18 100A, LC Column 50 x 0.3 mm- Pharma Screen
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 0.3 mm, microflow, Ea
26324
Chiral
Terfenadine on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20237
Chiral
Terfenadine on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20078
Reversed Phase
Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19946
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19943
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 100 x 2.1mm @ 0.85 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19940
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 75 x 2.1mm @ 1.1 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 75 x 2.1 mm, Ea
19939
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19914
Reversed Phase
Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19911
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19862
Chiral
Chiral SFC Purification of Terfenedine on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 21.2 mm, AXIA Packed, Ea
19273
Chiral
Chiral HPLC Purification of Terfenedine on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 21.2 mm, AXIA Packed, Ea
19272
Chiral
Terfenadine on Lux 5 µm Cellulose-1 by Chiral SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18909
Chiral
Terfenadine on Lux 5 µm Cellulose-2 by Chiral SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
18908
Chiral
Terfenadine on Lux 5 µm Cellulose-1 by Chiral SFC (loading and scale up)
Lux 5 µm Cellulose-1, LC Column 250 x 21.2 mm, AXIA Packed, Ea
18867
Chiral
Terfenadine on Lux 5 µm Cellulose-1 by Chiral SFC (loading and scale up)
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18866
Chiral
Terfenadine on Lux 5 µm Cellulose-1 by Chiral SFC (loading and scale up)
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18865
Chiral
Terfenadine on Lux 5µ Cellulose-2 in NP 95% Hexane
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17886
Chiral
Terfenadine on Lux 5µ Cellulose-2 in NP 95% Heptane
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17885
Chiral
Terfenadine on Lux 5µ Cellulose-1 in NP 95% Heptane
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17884
Chiral
Terfenadine on Lux 5µ Cellulose-1 250 x 4.6mm in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17662
Chiral
Terfenadine on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17420