Prilocaine on Lux 5µm Cellulose-1 in NP
LC Conditions
Column
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4459-E0
Phase Name
Cellulose-1
Elution Type
Isocratic
Mobile Phase
A: Hexane / EtOH (85:15) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-1, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8403 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Prilocaine
- 2. Prilocaine
-OEChem-06211003152D<br><br> 36 36 0 1 0 0 0 0 0999 V2000<br> 5.4641 -0.7500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.2500 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.7500 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.7500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 5.4641 2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 3.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2520 2.8326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8535 2.1423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 0.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5422 2.1674 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9407 2.8577 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0420 1.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4220 0.7131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 -0.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.9501 3.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 4.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7101 3.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -1.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -3.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -1.2131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 -2.2869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -3.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -4.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 7 2 0 0 0 0<br> 2 4 1 0 0 0 0<br> 2 5 1 0 0 0 0<br> 2 20 1 0 0 0 0<br> 3 7 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 3 26 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 8 1 0 0 0 0<br> 4 17 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 18 1 0 0 0 0<br> 5 19 1 0 0 0 0<br> 6 11 1 0 0 0 0<br> 6 21 1 0 0 0 0<br> 6 22 1 0 0 0 0<br> 8 23 1 0 0 0 0<br> 8 24 1 0 0 0 0<br> 8 25 1 0 0 0 0<br> 9 10 1 0 0 0 0<br> 9 12 2 0 0 0 0<br> 10 13 2 0 0 0 0<br> 10 14 1 0 0 0 0<br> 11 27 1 0 0 0 0<br> 11 28 1 0 0 0 0<br> 11 29 1 0 0 0 0<br> 12 15 1 0 0 0 0<br> 12 30 1 0 0 0 0<br> 13 16 1 0 0 0 0<br> 13 31 1 0 0 0 0<br> 14 32 1 0 0 0 0<br> 14 33 1 0 0 0 0<br> 14 34 1 0 0 0 0<br> 15 16 2 0 0 0 0<br> 15 35 1 0 0 0 0<br> 16 36 1 0 0 0 0<br>M END
Compound Name
Prilocaine
CID
4906
Molecular Formula
C13H20N2O
Molecular Weight
220
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
2
Similar Applications
Chiral
Prilocaine on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20545
Chiral
Prilocaine on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20102
Prilocaine on Lux 5µm Amylose-2 in NP
20081
Chiral
Prilocaine on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
19205
Chiral
Prilocaine on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
19203
Prilocaine on Lux 5 µm Amylose-2 250 x 4.6mm in NP
18114