Doxylamine on a ZB-Wax plus 15x0.25x0.25 by FID

Doxylamine on a ZB-Wax plus 15x0.25x0.25 by FID
GC Conditions
Column

Zebron ZB-WAXplus, GC Cap. Column 15 m x 0.25 mm x 0.25 µm, Ea

Part No

7EG-G013-11

Phase Name

ZB-WAXplus

Injection

Split 10:1 @ 250°C

Carrier Gas

Constant Flow Helium, 60.0 cm/sec

Detection

Flame Ionization (FID) @ (250°C)

Detection Info
Sample Notes

Doxylamine sample prepared as per USP 621 monograph.

Order Items Used in This Application

Zebron ZB-WAXplus, GC Cap. Column 15 m x 0.25 mm x 0.25 µm, Ea
7EG-G013-11

Zebron ZB-WAXplus, GC Cap. Column 15 m x 0.25 mm x 0.25 µm, Ea

View Product

  • 1. Doxylamine
-OEChem-06211003152D<br><br> 42 43  0     1  0  0  0  0  0999 V2000<br>    4.0000    0.0000    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0000   -1.7320    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8660   -1.5000    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000    0.0000    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    3.0000    1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5000   -0.8660    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5000   -0.8660    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.1340    1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8660    1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.1340   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.1340    2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8660    2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.1340   -2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000    3.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0000   -1.7320    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5000   -2.5981    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.8660   -2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000   -3.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.3800    0.0000    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000   -0.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.9174   -1.0781    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6077   -1.4766    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0826   -0.6540    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.3923   -0.2554    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.5970    1.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4030    1.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.5970   -1.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.5970    2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4030    2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.5970   -2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000    3.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0000   -2.3521    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.6200   -1.7320    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0000   -1.1120    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9631   -2.2881    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.1900   -3.1350    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0369   -2.9081    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.4030   -2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.0000   -3.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  4  1  0  0  0  0<br>  1  8  1  0  0  0  0<br>  2  9  1  0  0  0  0<br>  2 17  1  0  0  0  0<br>  2 18  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3 19  2  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4  6  1  0  0  0  0<br>  4  7  1  0  0  0  0<br>  5 10  2  0  0  0  0<br>  5 11  1  0  0  0  0<br>  6 12  2  0  0  0  0<br>  7 21  1  0  0  0  0<br>  7 22  1  0  0  0  0<br>  7 23  1  0  0  0  0<br>  8  9  1  0  0  0  0<br>  8 24  1  0  0  0  0<br>  8 25  1  0  0  0  0<br>  9 26  1  0  0  0  0<br>  9 27  1  0  0  0  0<br> 10 13  1  0  0  0  0<br> 10 28  1  0  0  0  0<br> 11 14  2  0  0  0  0<br> 11 29  1  0  0  0  0<br> 12 15  1  0  0  0  0<br> 12 30  1  0  0  0  0<br> 13 16  2  0  0  0  0<br> 13 31  1  0  0  0  0<br> 14 16  1  0  0  0  0<br> 14 32  1  0  0  0  0<br> 15 20  2  0  0  0  0<br> 15 33  1  0  0  0  0<br> 16 34  1  0  0  0  0<br> 17 35  1  0  0  0  0<br> 17 36  1  0  0  0  0<br> 17 37  1  0  0  0  0<br> 18 38  1  0  0  0  0<br> 18 39  1  0  0  0  0<br> 18 40  1  0  0  0  0<br> 19 20  1  0  0  0  0<br> 19 41  1  0  0  0  0<br> 20 42  1  0  0  0  0<br>M  END
Compound Name

Doxylamine

CID

3162

Molecular Formula

C17H22N2O

Molecular Weight

270

No. Hydrogen Bond Acceptors

3

Similar Applications

Reversed Phase

Cold Medications on Luna 3u Polar C18 100x4.6mm

Luna Omega 3 µm Polar C18 100 Å, LC Column 100 x 4.6 mm, Ea

24046

Improved Performance

ZB-5MSplus Drugs of Abuse

Zebron ZB-5MSplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, EA

23258

Reversed Phase

Doxylamine impurity profile on Kinetex 2.6 µm EVO C18

Kinetex 2.6 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea

23037

Reversed Phase

Cold medicine compounds on Kinetex 2.6 µm EVO C18

Kinetex 2.6 µm EVO C18 100 Å, LC Column 100 x 4.6 mm, EA

23036

Reversed Phase

Antihistamines on Kinetex 2.6u F5 50x4.6mm at pH 2.9 and pH 7.2

Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea

22838

Reversed Phase

Antihistamines using Kinetex 5u EVO C18 150x4.6mm

Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea

22716

Chiral

Doxylamine on Lux 5µm Cellulose-4 in NP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

20346

Chiral

Doxylamine on Lux 5µm Cellulose-1 in NP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

20252

Chiral

Doxylamine on Lux 5µm Cellulose-4 in RP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

20170

Application Specific

Drug screen by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18175

Chiral

Doxylamine on Lux 5µ Cellulose-1 in NP 95% Heptane

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17878

Chiral

Doxylamine on Lux 5µ Cellulose-1 in NP 95% Hexane

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17877

Chiral

Doxylamine on Lux 5µ Cellulose-2 in NP 80% Heptane

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

17876

Chiral

Doxylamine on Lux 5µ Cellulose-2 in NP 80% Hexane

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

17875

Standard

Drug Screen on ZB-XLB

Zebron ZB-XLB, GC Cap. Column 30 m x 0.25 mm x 0.50 µm, Ea

16463

Drug screen on ZB-5MSi

16421

High Temperature

Drug Screen on ZB-1HT

Zebron ZB-1HT, GC Cap. Column 30 m x 0.25 mm x 0.10 µm, Ea

16227

Standard

Common Drug Screen on ZB-50

Zebron ZB-50, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16012

Standard

Common Drug Screen on ZB-35

Zebron ZB-35, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

16010

Standard

Common Drug Screen on ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

16009

Common Drug Screen on ZB-1MS

16008