Methadone on Lux Cellulose-4 Normal Phase
LC Conditions
Column
Lux 5 µm Cellulose-4, LC Column 150 x 4.6 mm, Ea
Brand
Lux
Part No
00F-4491-E0
Phase Name
Cellulose-4
Elution Type
Isocratic
Mobile Phase
A: Hexane + 0.1%DEA
B: Isopropanol + 0.1% DEA
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
98
2
Flow Rate
1.50 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (22°C)
Detection Info
Sample Notes
Resolution = 1.89 Selectivity = 1.12
Order Items Used in This Application
- 1. Methadone
- 2. Methadone
-OEChem-06211003152D<br><br> 50 51 0 1 0 0 0 0 0999 V2000<br> 7.1454 0.8660 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9397 -0.3008 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 0.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6454 0.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7057 0.3420 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 5.6454 -1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6454 0.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5321 1.3268 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1454 -0.8660 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5115 -1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7794 1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7794 -1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5115 1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.0413 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1133 -1.2855 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1454 -0.8660 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5115 -2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7794 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7794 -2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5115 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 -3.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 3.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2200 -0.4510 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7531 0.6106 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9070 0.6327 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1427 1.4345 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4244 1.9374 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9215 1.2192 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5628 -1.0781 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2531 -1.4766 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0484 -1.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2425 1.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2425 -1.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0484 1.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2120 0.6239 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4174 0.2533 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7880 -0.5414 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5027 -1.3931 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2209 -1.8961 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7239 -1.1779 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1454 -1.4860 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.7654 -0.8660 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1454 -0.2460 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0484 -2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2425 2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2425 -2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0484 2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 -3.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 3.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 8 2 0 0 0 0<br> 2 5 1 0 0 0 0<br> 2 15 1 0 0 0 0<br> 2 16 1 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 7 1 0 0 0 0<br> 3 8 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 24 1 0 0 0 0<br> 4 25 1 0 0 0 0<br> 5 9 1 0 0 0 0<br> 5 26 1 0 0 0 0<br> 6 11 2 0 0 0 0<br> 6 13 1 0 0 0 0<br> 7 12 2 0 0 0 0<br> 7 14 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 9 27 1 0 0 0 0<br> 9 28 1 0 0 0 0<br> 9 29 1 0 0 0 0<br> 10 17 1 0 0 0 0<br> 10 30 1 0 0 0 0<br> 10 31 1 0 0 0 0<br> 11 18 1 0 0 0 0<br> 11 32 1 0 0 0 0<br> 12 19 1 0 0 0 0<br> 12 33 1 0 0 0 0<br> 13 20 2 0 0 0 0<br> 13 34 1 0 0 0 0<br> 14 21 2 0 0 0 0<br> 14 35 1 0 0 0 0<br> 15 36 1 0 0 0 0<br> 15 37 1 0 0 0 0<br> 15 38 1 0 0 0 0<br> 16 39 1 0 0 0 0<br> 16 40 1 0 0 0 0<br> 16 41 1 0 0 0 0<br> 17 42 1 0 0 0 0<br> 17 43 1 0 0 0 0<br> 17 44 1 0 0 0 0<br> 18 22 2 0 0 0 0<br> 18 45 1 0 0 0 0<br> 19 23 2 0 0 0 0<br> 19 46 1 0 0 0 0<br> 20 22 1 0 0 0 0<br> 20 47 1 0 0 0 0<br> 21 23 1 0 0 0 0<br> 21 48 1 0 0 0 0<br> 22 49 1 0 0 0 0<br> 23 50 1 0 0 0 0<br>M END
Compound Name
Methadone
CID
4095
Molecular Formula
C21H27NO
Molecular Weight
309
No. Hydrogen Bond Acceptors
2
Similar Applications
Reversed Phase
7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea
23560
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u Biphenyl 50x2.1mm
Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
23445
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23444
Reversed Phase
Opiates at high pH using Kinetex 5u EVO C18 50 x 2.1 mm
Kinetex 5 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
22715
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
22122
Reversed Phase
Fast Pain Panel using Kinetex 2.6 u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22121
Reversed Phase
Full Pain Panel using Kinetex 5um Biphenyl 50x3.0mm
Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22120
Reversed Phase
Pain Panel Opiates using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22108
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22104
Reversed Phase
Opiates using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
21972
Chiral
Methadone on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21202
Chiral
Methadone on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21201
Chiral
Methadone on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21200
Chiral
Methadone on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21199
Chiral
Methadone on Lux Cellulose-2 Normal Phase
Lux 5 µm Cellulose-2, LC Column 150 x 4.6 mm, Ea
19699
Chiral
Methadone on Lux Cellulose-4 Normal Phase
Lux 5 µm Cellulose-4, LC Column 150 x 4.6 mm, Ea
19698
Chiral
Methadone on Lux 5 um Cellulose-2 250 x 4.6
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
18456