Green Tea extracts/catechins on Kinetex 2.6u C18 100x2.10mm @0.36mL/min using Shimadzu Nexera
LC Conditions
Column
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
Brand
Kinetex
Part No
00D-4462-AN
Phase Name
C18
Elution Type
Gradient
Mobile Phase
A: 0.1% Phosphoric Acid in Water
B: 0.1% Phosphoric Acid in Acetonitrile
Gradient Profile
Step No.
Time(min)
%A
%B
1
0.01
85
15
2
0.45
85
15
3
2.68
65
35
4
3.34
10
90
5
3.35
85
15
6
5.34
85
15
Flow Rate
0.36 mL/min
Temperature
0°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Order Items Used in This Application
- 1. Epigallocatechin
- 2. Catechin
- 3. Epicatechin
- 4. Epigallocatechin gallate
- 5. Epicatechin gallate
-OEChem-05151001062D<br><br> 36 38 0 1 0 0 0 0 0999 V2000<br> 6.3301 0.2704 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.7296 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0785 -2.7642 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.8602 0.2945 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 2.7704 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.2296 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 1.7704 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.2296 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 5.4641 -0.2296 0.0000 C 0 0 1 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.7296 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -1.2296 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.2704 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -0.2296 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0901 -1.7643 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0901 0.3051 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.2296 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.2704 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9962 -1.2504 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9962 -0.2088 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.7704 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 0.2704 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.2704 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.8496 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.3904 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.9316 -2.2046 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7287 -2.2046 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0829 0.9250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.8496 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 1.5804 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.3496 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.5319 -1.5625 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6118 -3.0804 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.3984 -0.0134 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 3.0804 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.8496 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 2.3904 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 9 1 0 0 0 0<br> 1 13 1 0 0 0 0<br> 8 2 1 1 0 0 0<br> 2 30 1 0 0 0 0<br> 3 14 1 0 0 0 0<br> 3 32 1 0 0 0 0<br> 4 19 1 0 0 0 0<br> 4 33 1 0 0 0 0<br> 5 20 1 0 0 0 0<br> 5 34 1 0 0 0 0<br> 6 21 1 0 0 0 0<br> 6 35 1 0 0 0 0<br> 7 22 1 0 0 0 0<br> 7 36 1 0 0 0 0<br> 8 9 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 8 23 1 0 0 0 0<br> 9 12 1 1 0 0 0<br> 9 24 1 0 0 0 0<br> 10 11 1 0 0 0 0<br> 10 25 1 0 0 0 0<br> 10 26 1 0 0 0 0<br> 11 13 1 0 0 0 0<br> 11 14 2 0 0 0 0<br> 12 16 2 0 0 0 0<br> 12 17 1 0 0 0 0<br> 13 15 2 0 0 0 0<br> 14 18 1 0 0 0 0<br> 15 19 1 0 0 0 0<br> 15 27 1 0 0 0 0<br> 16 21 1 0 0 0 0<br> 16 28 1 0 0 0 0<br> 17 20 2 0 0 0 0<br> 17 29 1 0 0 0 0<br> 18 19 2 0 0 0 0<br> 18 31 1 0 0 0 0<br> 20 22 1 0 0 0 0<br> 21 22 2 0 0 0 0<br>M END
Compound Name
Epigallocatechin
CID
72277
Molecular Formula
C15H14O7
Molecular Weight
306
No. Hydrogen Bond Acceptors
7
No. Hydrogen Bond Donors
6
Similar Applications
Reversed Phase
Green Tea extracts/catechins on Kinetex 2.6u C18 100x2.10mm @0.36mL/min using Shimadzu Nexera
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19969
Reversed Phase
Green Tea extracts/catechins on Kinetex 1.7u C18 100x2.10mm using Shimadzu Nexera
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19953
Reversed Phase
Green Tea extracts/catechins on Kinetex 2.6u XB-C18 100x4.60mm on Shimadzu Nexera
Kinetex 2.6 µm XB-C18 100 Å, LC Column 100 x 4.6 mm, Ea
19952
Reversed Phase
Green Tea extracts/catechins on Kinetex 2.6u C18 100x4.60mm on Shimadzu Nexera
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
19951
Reversed Phase
Catechins on Kinetex 2.6µm PFP 150 x 4.6mm ID
Kinetex 2.6 µm PFP 100 Å, LC Column 150 x 4.6 mm, Ea
18656
Reversed Phase
Catechins on Kinetex 2.6µm C18 150 x 4.6mm ID
Kinetex 2.6 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
18655
Reversed Phase
Catechins on Luna 3µm C18(2) 150 x 4.6mm ID
Luna 3 µm C18(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16295
Reversed Phase
Catechins on Luna 3µm PFP(2) 150 x 4.6mm ID
Luna 3 µm PFP(2) 100 Å, LC Column 150 x 4.6 mm, Ea
16294
Reversed Phase
Catechins by Luna 3µ Phenyl-Hexyl MercuryMS Cartridge 20 x 2.0mm
Luna 3 µm Phenyl-Hexyl 100 Å, LC Column 20 x 2 mm, MercuryMS, Ea
15617
Reversed Phase
Catechins by Luna 3µ C18(2) MercuryMS cartridge 20 x 2.0mm
Luna 3 µm C18(2) 100 Å, LC Column 20 x 2 mm, MercuryMS, Ea
15616
Reversed Phase
Catechins by Luna 3µ C18(2) MercuryMS Cartridge 20 x 4.0mm
Luna 3 µm C18(2) 100 Å, LC Column 20 x 4 mm, MercuryMS, Ea
15614
Reversed Phase
Green Tea
Luna 5 µm Phenyl-Hexyl 100 Å, LC Column 250 x 4.6 mm, Ea
14436
Reversed Phase
Australian Green Tea (Comellia sinensis)
Prodigy 5 µm ODS-3 100 Å, LC Column 150 x 4.6 mm, Ea
1135
Reversed Phase
Chinese Green Tea (Comellia sinensis)
Prodigy 5 µm ODS-3 100 Å, LC Column 150 x 4.6 mm, Ea
1134
Reversed Phase
Japanese Green Tea (Comellia sinensis)
Prodigy 5 µm ODS-3 100 Å, LC Column 150 x 4.6 mm, Ea
1133