Clenbuterol on Lux 5µm Cellulose-2 in RP
LC Conditions
Column
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4457-E0
Phase Name
Cellulose-2
Elution Type
Isocratic
Mobile Phase
A: ACN / 20mM NH4AC (30:70) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-2, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8366 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Clenbuterol
- 2. Clenbuterol
-OEChem-06211003152D<br><br> 35 35 0 1 0 0 0 0 0999 V2000<br> 2.8660 2.2780 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 2.2780 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.2220 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.2220 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 3.2780 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.7220 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.2220 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.7220 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 2.0000 -3.2220 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3660 -3.5880 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3660 -1.8560 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.2780 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.7780 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.7780 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.7780 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.7780 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.2780 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -2.5320 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5200 -0.6394 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1215 -1.3296 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.3420 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 -2.6850 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -3.5320 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 -3.7589 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8291 -3.8980 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.6760 -4.1250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9030 -3.2780 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9030 -1.5460 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0560 -1.3190 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.8291 -2.1660 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 0.4680 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 0.4680 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.8420 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 3.5880 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 3.5880 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 15 1 0 0 0 0<br> 2 16 1 0 0 0 0<br> 3 8 1 0 0 0 0<br> 3 33 1 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 18 1 0 0 0 0<br> 5 17 1 0 0 0 0<br> 5 34 1 0 0 0 0<br> 5 35 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 10 1 0 0 0 0<br> 6 11 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 19 1 0 0 0 0<br> 7 20 1 0 0 0 0<br> 8 12 1 0 0 0 0<br> 8 21 1 0 0 0 0<br> 9 22 1 0 0 0 0<br> 9 23 1 0 0 0 0<br> 9 24 1 0 0 0 0<br> 10 25 1 0 0 0 0<br> 10 26 1 0 0 0 0<br> 10 27 1 0 0 0 0<br> 11 28 1 0 0 0 0<br> 11 29 1 0 0 0 0<br> 11 30 1 0 0 0 0<br> 12 13 2 0 0 0 0<br> 12 14 1 0 0 0 0<br> 13 16 1 0 0 0 0<br> 13 31 1 0 0 0 0<br> 14 15 2 0 0 0 0<br> 14 32 1 0 0 0 0<br> 15 17 1 0 0 0 0<br> 16 17 2 0 0 0 0<br>M END
Compound Name
Clenbuterol
CID
2783
Molecular Formula
C12H18Cl2N2O
Molecular Weight
277
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
3
Similar Applications
Reversed Phase
Antibiotics by LCMS using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
22161
Chiral
Clenbuterol on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20399
Chiral
Clenbuterol on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20194
Chiral
Clenbuterol on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20071
Chiral
Clenbutanol on Lux 5µ Cellulose-2 in RP 40%CH3CN
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17855
Chiral
Clenbutanol on Lux 5µ Cellulose-2 in RP 30%CH3CN
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17854
Chiral
Clenbuterol on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17506
Chiral
Clenbuterol on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17505
Chiral
Clenbuterol on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17504