Tropicamide on Lux 5µm Cellulose-2 in NP
LC Conditions
Column
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4457-E0
Phase Name
Cellulose-2
Elution Type
Isocratic
Mobile Phase
A: Hexane / EtOH (40/:60) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-2, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8366 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Tropicamide
- 2. Tropicamide
-OEChem-06211003152D<br><br> 41 42 0 1 0 0 0 0 0999 V2000<br> 5.1350 -1.0000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 0.5000 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 0.5000 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 4.0000 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -1.0000 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.2690 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 -3.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5369 -3.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -4.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 3.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 3.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -0.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.3471 0.4174 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7456 1.1077 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.7924 1.1077 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1909 0.4174 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.9264 -0.3923 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3249 -1.0826 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8059 -2.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0230 2.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 2.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.7830 2.0000 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 2.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5380 2.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8059 -3.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -3.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4030 -4.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 3.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5380 3.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 6 2 0 0 0 0<br> 2 10 1 0 0 0 0<br> 2 39 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 7 1 0 0 0 0<br> 3 9 1 0 0 0 0<br> 4 20 2 0 0 0 0<br> 4 21 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 10 1 0 0 0 0<br> 5 22 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 7 23 1 0 0 0 0<br> 7 24 1 0 0 0 0<br> 8 12 2 0 0 0 0<br> 8 13 1 0 0 0 0<br> 9 14 1 0 0 0 0<br> 9 25 1 0 0 0 0<br> 9 26 1 0 0 0 0<br> 10 27 1 0 0 0 0<br> 10 28 1 0 0 0 0<br> 11 15 2 0 0 0 0<br> 11 16 1 0 0 0 0<br> 12 17 1 0 0 0 0<br> 12 29 1 0 0 0 0<br> 13 18 2 0 0 0 0<br> 13 30 1 0 0 0 0<br> 14 31 1 0 0 0 0<br> 14 32 1 0 0 0 0<br> 14 33 1 0 0 0 0<br> 15 20 1 0 0 0 0<br> 15 34 1 0 0 0 0<br> 16 21 2 0 0 0 0<br> 16 35 1 0 0 0 0<br> 17 19 2 0 0 0 0<br> 17 36 1 0 0 0 0<br> 18 19 1 0 0 0 0<br> 18 37 1 0 0 0 0<br> 19 38 1 0 0 0 0<br> 20 40 1 0 0 0 0<br> 21 41 1 0 0 0 0<br>M END
Compound Name
Tropicamide
CID
5593
Molecular Formula
C17H20N2O2
Molecular Weight
284
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
1
Similar Applications
Chiral
Chiral Separation of Tropicamide on Lux 5µm i-Amylose-1 in NP
Lux 5 µm i-Amylose-1, LC Column 250 x 4.6 mm, Ea
24495
Chiral
Tropicamide on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20241
Chiral
Tropicamide on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20160
Chiral
Tropicamide on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20122
Chiral
Tropicamide on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
16707