Pindolol on Lux 5µm Cellulose-1 in RP
LC Conditions
Column
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4459-E0
Phase Name
Cellulose-1
Elution Type
Isocratic
Mobile Phase
A: MeOH / 20mM NH4AC (80:20) with DEA (0.1%) in buffer
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-1, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8403 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Pindolol
- 2. Pindolol
-OEChem-06211003152D<br><br> 38 39 0 1 0 0 0 0 0999 V2000<br> 5.4641 -0.5530 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.4470 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 2.4470 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2764 -3.3577 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.9470 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 3.7320 1.4470 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.9470 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.0530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -2.0530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.5530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 3.9470 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 2.4470 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -3.0530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2764 -1.7482 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.0530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -3.5530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8600 -2.5530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.0530 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.5670 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1215 1.5547 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5200 0.8644 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.3270 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 2.7570 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9875 0.0547 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3860 -0.6356 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4860 3.9470 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 4.5670 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2460 3.9470 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 2.9840 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 2.1370 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 1.9101 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4690 -1.1589 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 -1.7430 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 2.0670 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4690 -3.9470 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -4.1730 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.4800 -2.5530 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0611 -3.3630 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 8 1 0 0 0 0<br> 1 10 1 0 0 0 0<br> 2 5 1 0 0 0 0<br> 2 34 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 7 1 0 0 0 0<br> 3 23 1 0 0 0 0<br> 4 13 1 0 0 0 0<br> 4 17 1 0 0 0 0<br> 4 35 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 19 1 0 0 0 0<br> 6 20 1 0 0 0 0<br> 6 21 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 7 12 1 0 0 0 0<br> 7 22 1 0 0 0 0<br> 8 24 1 0 0 0 0<br> 8 25 1 0 0 0 0<br> 9 10 1 0 0 0 0<br> 9 13 2 0 0 0 0<br> 9 14 1 0 0 0 0<br> 10 15 2 0 0 0 0<br> 11 26 1 0 0 0 0<br> 11 27 1 0 0 0 0<br> 11 28 1 0 0 0 0<br> 12 29 1 0 0 0 0<br> 12 30 1 0 0 0 0<br> 12 31 1 0 0 0 0<br> 13 16 1 0 0 0 0<br> 14 17 2 0 0 0 0<br> 14 32 1 0 0 0 0<br> 15 18 1 0 0 0 0<br> 15 33 1 0 0 0 0<br> 16 18 2 0 0 0 0<br> 16 36 1 0 0 0 0<br> 17 37 1 0 0 0 0<br> 18 38 1 0 0 0 0<br>M END
Compound Name
Pindolol
CID
4828
Molecular Formula
C14H20N2O2
Molecular Weight
248
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
3
Similar Applications
Reversed Phase
ABN7 using Method Transfer Scaling Calculator on Luna Omega 5 µm C18 250 x 4.6 mm with Agilent 1260 Binary UHPLC
Luna Omega 5 µm C18 100 Å, LC Column 250 x 4.6 mm, Ea
26804
Reversed Phase
ABN7 using Method Transfer Scaling Calculator on Luna Omega 3 µm C18 150 x 4.6 mm with Agilent 1260 Binary UHPLC
Luna Omega 3 µm C18 100 Å, LC Column 150 x 4.6 mm, Ea
26803
Reversed Phase
ABN7 using Method Transfer Scaling Calculator on Luna Omega 1.6 µm C18 50 x 2.1 mm with Agilent 1260 Binary UHPLC
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
26802
Reversed Phase
Kinetex 2.6u C18 100A and LC Column 150 x 0.3 mm- Pharma Screen
Kinetex 2.6 µm C18 100 Å, LC Column 150 x 0.3 mm, Capillary, Ea
26400
Reversed Phase
Kinetex 2.6u C18 100A, LC Column 50 x 0.3 mm- Pharma Screen
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 0.3 mm, Capillary, Ea
26399
Reversed Phase
Kinetex 2.6u XB-C18 100A, LC Column 50 x 0.3 mm- Pharma Screen
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 0.3 mm, microflow, Ea
26324
ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (7914) (Methanol)
25435
ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (Methanol)
25434
Reversed Phase
ABN7 in Formic Acid Screening on 2.6u Kinetex PS C18 50x4.6mm (0361) (Acetonitrile)
Kinetex 2.6 µm PS C18 100 Å, LC Column 50 x 4.6 mm, Ea
25424
ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (7914) (Acetonitrile)
25422
ABN7 in Formic Acid Screening on 2.7u Waters Cortecs C18+ 50x4.6mm (7306) (Acetonitrile)
25417
Reversed Phase
Beta-blockers using Luna Omega 1.6u PS C18 50x2.1mm
Luna Omega 1.6µm PS C18 100Å, LC Column 50 x 2.1 mm, EA
23727
Reversed Phase
ABN7 on Luna Omega 1.6u PS C18 50x2.1mm
Luna Omega 1.6µm PS C18 100Å, LC Column 50 x 2.1 mm, EA
23707
Reversed Phase
Beta-blockers using Luna Omega Polar C18 50x2.1mm
Luna Omega 1.6µm Polar C18 100Å, LC Column 50 x 2.1 mm, EA
23611
Chiral
Pindolol on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23290
Chiral
Pindolol on LUX Amylose-1 5u 250x4.6mm in PO
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23182
Reversed Phase
ABN6 Mix on Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23068
Reversed Phase
Pharmaceutical Mix on Kinetex 1.7 F5 50x2.1mm
Kinetex 1.7 µm F5 100 Å, LC Column 50 x 2.1 mm, Ea
22813
Reversed Phase
Batch Reproducibility with ABN 7 mix- Kinetex 2.6u F5 50x4.6mm
Kinetex 2.6 µm F5 100 Å, LC Column 50 x 4.6 mm, Ea
22803
Reversed Phase
Batch reproducibility of Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22734
Reversed Phase
Pharma ABN Mixture using Kinetex 5u EVO C18 150x4.6mm
Kinetex 5 µm EVO C18 100 Å, LC Column 150 x 4.6 mm, Ea
22718
Chiral
Pindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21311
Chiral
Pindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21310
Chiral
Pindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21309
Chiral
Pindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21308
Chiral
Pindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21307
Chiral
Pindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21306
Chiral
Pindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21305
Chiral
Pindolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21304
Chiral
Pindolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21303
Chiral
Pindolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21302
Chiral
Mepindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21189
Chiral
Mepindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21188
Chiral
Mepindolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21187
Chiral
Mepindolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21186
Chiral
Mepindolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21185
Chiral
Bopindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21065
Chiral
Bopindolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21064
Chiral
Bopindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21063
Chiral
Bopindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21062
Chiral
Bopindolol on Lux 5µm Cellulose-3 by SFC
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
21061
Chiral
Bopindolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21060
Chiral
Bopindolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21059
Chiral
Bopindolol on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20492
Chiral
Pindolol on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20466
Chiral
Pindolol on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20350
Chiral
Pindolol on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20198
Chiral
Bopindolol on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20173
Chiral
Pindolol on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20125
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 1.7u C18 100x2.1mm @ 0.60mL/min
Kinetex 1.7 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20054
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6u C18 100x2.1mm @ 0.60mL/min
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20053
Reversed Phase
Pharma ABN Test 15 Mix on Waters Acquity UPLC using Kinetex 2.6 C18 100x2.1mm @ 1.0mL/min
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
20050
Reversed Phase
Pharma ABN Test 15 Mix on Un-Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20049
Reversed Phase
Pharma ABN Test 15 Mix on Optimized Agilent 1100 system using Kinetex 2.6u C18 100x4.6mm
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 4.6 mm, Ea
20048
Reversed Phase
Pharma ABN Test 15 Mix on Kinetex 2.6u C18 50x2.10mm @ 1.45mL/min 5min gradient
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
20041
Reversed Phase
Pharma ABN Test 15 Mix on Kinetex 1.7u C18 50x2.10mm @ 1.0mL/min 5min gradient
Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
20040
Reversed Phase
Pharma ABN Test 15 Mix on Kinetex 2.6u C18 50x2.10mm @ 0.8mL/min 5 ming gradient
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
20039
Reversed Phase
Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19944
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotien Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19941
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 100 x 2.1mm @ 0.85 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 100 x 2.1 mm, Ea
19940
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 75 x 2.1mm @ 1.1 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 75 x 2.1 mm, Ea
19939
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19914
Reversed Phase
Pharmaceutical Drug Mix on Kinetex 2.6 µm C18 50 x 2.1mm @ 0.8 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19911
Reversed Phase
Pharmaceutical Drug Mix on Kinetex C18 2.6u 50 x 2.1mm @ 1.4 mL/min(Quotient Data)
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19862
Reversed Phase
Pharma ABN Test 11 Mix on Kinetex 2.6u C18 150x2.10mm using Acquity UPLC system
Kinetex 2.6 µm C18 100 Å, LC Column 150 x 2.1 mm, Ea
19789
Reversed Phase
Pharma ABN Test 11 Mix on Kinetex 1.7u C18 150x2.10mm using Acquity UPLC system
Kinetex 1.7 µm XB-C18 100 Å, LC Column 150 x 2.1 mm, Ea
19788
Reversed Phase
Pharma ABN Test 12 Mix on Kinetex 1.7u C18 50x2.10mm using Acquity UPLC system
Kinetex 1.7 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19785
Reversed Phase
Pharma ABN Test 12 Mix on Kinetex 2.6u C18 50x2.10mm using Acquity UPLC system
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19784
Reversed Phase
Pharmaceutical Mixture on Kinetex 2.6µm C8 50x2.1mm ID
Kinetex 2.6 µm C8 100 Å, LC Column 50 x 2.1 mm, Ea
19476
Reversed Phase
Pharmaceutical Mixture on Kinetex XB-C18
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 2.1 mm, Ea
19475
Reversed Phase
Pharmaceutical Mixture on Kinetex C18
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19474
RP Enantioseparation of Bopidolol on Lux Amylose-2
19446
Chiral
RP Enantioseparation of Bopidolol on Lux Cellulose-1
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19445
Chiral
RP Enantioseparation of Pindolol on Lux Cellulose-1
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19440
Chiral
Bopindolol on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
19193
Chiral
Bopindolol on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
19191
Chiral
Bopindolol on Lux 5 µm Cellulose-1 by Chiral SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18861
Chiral
Bopindolol on Lux 5 µm Cellulose-2 by Chiral SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
18860
Chiral
Pindolol on Lux 5µ Cellulose-2 in RP 20% CH3CN
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17868
Chiral
Pindolol on Lux 5µ Cellulose-2 in RP 60%MeOH
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17865
Chiral
Pindolol on Lux 5µ Cellulose-1 in RP 80% MeOH-2
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17864
Chiral
Pindolol on Lux 5µ Cellulose-1 in RP 80% MeOH-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17863
Chiral
Pindolol on Lux 5µ Cellulose-1 in RP 60% CH3CN
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17862
Chiral
Pindolol on Lux 5µ Cellulose-1 in RP 40% CH3CN
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17861
Chiral
Bopindolol on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17484
Chiral
Bopindolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17483
Chiral
Pindolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17384
Chiral
Bopindolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
16715