Miconazole on Lux 5µm Cellulose-2 in RP
LC Conditions
Column
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4457-E0
Phase Name
Cellulose-2
Elution Type
Isocratic
Mobile Phase
A: ACN / 20mM NH4HCO3 +0.1%DEA(80:20) with None in buffer
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-2, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8366 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Miconazole
- 2. Miconazole
-OEChem-06211003152D<br><br> 39 41 0 1 0 0 0 0 0999 V2000<br> 4.5981 -0.7500 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -3.7500 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 3.7500 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 3.7500 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.7500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 1.7500 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6962 3.2888 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 0.2500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 7.1962 0.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0052 2.3378 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3871 2.3378 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6962 3.2888 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 3.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5940 -0.1750 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4082 0.1674 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8067 0.8577 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0747 1.6423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6762 2.3326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 -0.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.5948 2.1462 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7975 2.1462 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9272 -2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 -2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0606 3.7904 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.1300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 4.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 1.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 12 1 0 0 0 0<br> 2 19 1 0 0 0 0<br> 3 21 1 0 0 0 0<br> 4 25 1 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 11 1 0 0 0 0<br> 6 9 1 0 0 0 0<br> 6 15 1 0 0 0 0<br> 6 16 1 0 0 0 0<br> 7 16 2 0 0 0 0<br> 7 20 1 0 0 0 0<br> 8 9 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 8 26 1 0 0 0 0<br> 9 27 1 0 0 0 0<br> 9 28 1 0 0 0 0<br> 10 12 2 0 0 0 0<br> 10 13 1 0 0 0 0<br> 11 14 1 0 0 0 0<br> 11 29 1 0 0 0 0<br> 11 30 1 0 0 0 0<br> 12 17 1 0 0 0 0<br> 13 18 2 0 0 0 0<br> 13 31 1 0 0 0 0<br> 14 21 2 0 0 0 0<br> 14 22 1 0 0 0 0<br> 15 20 2 0 0 0 0<br> 15 32 1 0 0 0 0<br> 16 33 1 0 0 0 0<br> 17 19 2 0 0 0 0<br> 17 34 1 0 0 0 0<br> 18 19 1 0 0 0 0<br> 18 35 1 0 0 0 0<br> 20 36 1 0 0 0 0<br> 21 23 1 0 0 0 0<br> 22 24 2 0 0 0 0<br> 22 37 1 0 0 0 0<br> 23 25 2 0 0 0 0<br> 23 38 1 0 0 0 0<br> 24 25 1 0 0 0 0<br> 24 39 1 0 0 0 0<br>M END
Compound Name
Miconazole
CID
4189
Molecular Formula
C18H14Cl4N2O
Molecular Weight
416
No. Hydrogen Bond Acceptors
2
Similar Applications
Reversed Phase
USP Miconazole Nitrate – Assay and Organic Impurities; Organic Impurities Standard solution on Kinetex 2.6 µm Phenyl-Hexyl 100 x 4.6 mm using Waters ACQUITY I-Class
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 100 x 4.6 mm, Ea
26865
Reversed Phase
USP Miconazole Nitrate – Assay and Organic Impurities; Assay System Suitability solution on Kinetex 2.6 µm Phenyl-Hexyl 100 x 4.6 mm using Waters ACQUITY I-Class
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 100 x 4.6 mm, Ea
26864
Reversed Phase
USP Miconazole Nitrate – Assay and Organic Impurities; Assay Standard solution on Kinetex 2.6 µm Phenyl-Hexyl 100 x 4.6 mm using Waters ACQUITY I-Class
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 100 x 4.6 mm, Ea
26863
Chiral
Miconazole on Lux 5µm Cellulose-3 in PO
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20359
Chiral
Miconazole on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20342
Chiral
Miconazole on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20290
Chiral
Miconazole on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20226
Chiral
Miconazole on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20156
Chiral
Miconazole on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20129
Chiral
Miconazole on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20124
RP Enantioseparation of Miconazole on Lux Amylose-2
19431
Chiral
RP Enantioseparation of Miconaxole on Lux Cellulose-2
Lux 3 µm Cellulose-2, LC Column 150 x 2 mm, Ea
19403
Chiral
Miconazole on Lux 5µ Cellulose-1 250 x 4.6mm in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17659
Chiral
Miconazole on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17369
Chiral
Miconazole on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17367