Orphenedrine on Lux 5µm Cellulose-1 in RP
LC Conditions
Column
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4459-E0
Phase Name
Cellulose-1
Elution Type
Isocratic
Mobile Phase
A: ACN / 20mM NH4HCO3+0.1%DEA (60:40) with None in buffer
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-1, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8403 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Orphenadrine
- 2. Orphenadrine
-OEChem-06211003152D<br><br> 43 44 0 1 0 0 0 0 0999 V2000<br> 3.7320 0.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.7500 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.2500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3426 1.1423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.9441 1.8326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2554 1.8577 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6540 1.1674 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -1.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9272 1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -0.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 -3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1760 -0.7131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -0.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5560 -1.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -3.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 2.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 -0.0600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3100 3.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 3.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.6900 2.7131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.0420 2.7131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 3.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4220 3.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 1.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 3 1 0 0 0 0<br> 1 6 1 0 0 0 0<br> 2 8 1 0 0 0 0<br> 2 18 1 0 0 0 0<br> 2 19 1 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 21 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 9 2 0 0 0 0<br> 5 10 2 0 0 0 0<br> 5 11 1 0 0 0 0<br> 6 8 1 0 0 0 0<br> 6 22 1 0 0 0 0<br> 6 23 1 0 0 0 0<br> 7 12 2 0 0 0 0<br> 7 13 1 0 0 0 0<br> 8 24 1 0 0 0 0<br> 8 25 1 0 0 0 0<br> 9 14 1 0 0 0 0<br> 9 26 1 0 0 0 0<br> 10 16 1 0 0 0 0<br> 10 27 1 0 0 0 0<br> 11 17 2 0 0 0 0<br> 11 28 1 0 0 0 0<br> 12 15 1 0 0 0 0<br> 12 29 1 0 0 0 0<br> 13 30 1 0 0 0 0<br> 13 31 1 0 0 0 0<br> 13 32 1 0 0 0 0<br> 14 15 2 0 0 0 0<br> 14 33 1 0 0 0 0<br> 15 34 1 0 0 0 0<br> 16 20 2 0 0 0 0<br> 16 35 1 0 0 0 0<br> 17 20 1 0 0 0 0<br> 17 36 1 0 0 0 0<br> 18 37 1 0 0 0 0<br> 18 38 1 0 0 0 0<br> 18 39 1 0 0 0 0<br> 19 40 1 0 0 0 0<br> 19 41 1 0 0 0 0<br> 19 42 1 0 0 0 0<br> 20 43 1 0 0 0 0<br>M END
Compound Name
Orphenadrine
CID
4601
Molecular Formula
C18H23NO
Molecular Weight
269
No. Hydrogen Bond Acceptors
2
Similar Applications
Chiral
Orphenedrine on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20299
Chiral
Orphenedrine on Lux 5µm Cellulose-1 in RP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20231
Chiral
Effect of Buffer on RP Enantioseparation of Orphenadrin on Lux Cellulose-1
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19370
Chiral
Orphenedrine on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
19201
Chiral
Orphenedrine on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
19199
Chiral
Orphenadrine on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17374
Chiral
Orphenidrine on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17327