Norketamine on Lux 5µm Cellulose-3 in RP
LC Conditions
Column
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4493-E0
Phase Name
Cellulose-3
Elution Type
Isocratic
Mobile Phase
A: MeOH / 20mM NH4HCO3+0.1%DEA (80:20) None
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-3 4 x 3.0 mm, 10/Pk Part No.: AJ0-8622 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Norketamine
- 2. Norketamine
-OEChem-05271007432D<br><br> 29 30 0 1 0 0 0 0 0999 V2000<br> 5.6114 -0.8192 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -0.1352 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2320 0.7308 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.1352 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.6352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.6352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.1352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.6352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -0.6352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.4981 0.5076 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4378 0.1656 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.3244 1.4924 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2038 0.8084 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.0905 2.1352 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0302 1.7932 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2087 -0.7429 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8101 -0.0526 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8101 -2.2178 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2087 -1.5275 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3335 -2.6101 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1306 -2.6101 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2554 -1.5275 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6540 -2.2178 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.6120 0.7308 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3397 1.3414 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7418 1.7045 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.7864 0.5963 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9828 2.7458 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5051 2.1917 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 11 1 0 0 0 0<br> 2 9 2 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 24 1 0 0 0 0<br> 3 25 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 9 1 0 0 0 0<br> 4 10 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 16 1 0 0 0 0<br> 5 17 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 18 1 0 0 0 0<br> 6 19 1 0 0 0 0<br> 7 8 1 0 0 0 0<br> 7 20 1 0 0 0 0<br> 7 21 1 0 0 0 0<br> 8 9 1 0 0 0 0<br> 8 22 1 0 0 0 0<br> 8 23 1 0 0 0 0<br> 10 11 1 0 0 0 0<br> 10 12 2 0 0 0 0<br> 11 13 2 0 0 0 0<br> 12 14 1 0 0 0 0<br> 12 26 1 0 0 0 0<br> 13 15 1 0 0 0 0<br> 13 27 1 0 0 0 0<br> 14 15 2 0 0 0 0<br> 14 28 1 0 0 0 0<br> 15 29 1 0 0 0 0<br>M END
Compound Name
Norketamine
CID
123767
Molecular Formula
C12H14ClNO
Molecular Weight
223
No. Hydrogen Bond Acceptors
2
No. Hydrogen Bond Donors
1
Similar Applications
Chiral
Norketamine on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20337
Chiral
Norketamine on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20131
RP Enantioseparation of Ketamine and Norketamine on Lux Amylose-2