Bifonazole on Lux 5µm Cellulose-4 in NP
LC Conditions
Column
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4491-E0
Phase Name
Cellulose-4
Elution Type
Isocratic
Mobile Phase
A: Hexane / IPA (80:20) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-4 4 x 3.0 mm, 10/Pk Part No.: AJ0-8627 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Bifonazole
- 2. Bifonazole
-OEChem-06211003142D<br><br> 42 45 0 1 0 0 0 0 0999 V2000<br> 5.4641 2.5000 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5468 3.7024 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.0000 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 4.5981 1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 3.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3776 2.0933 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5686 3.4945 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 4.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0468 2.8364 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 3.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -3.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -4.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 2.8500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 0.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 0.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 1.3800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2690 3.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -0.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 -0.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5066 1.4868 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1079 3.9094 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 2.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 4.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.6634 2.7716 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 3.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -2.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 -2.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -3.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1951 -3.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -4.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 3 1 0 0 0 0<br> 1 13 1 0 0 0 0<br> 1 14 1 0 0 0 0<br> 2 14 2 0 0 0 0<br> 2 18 1 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 5 1 0 0 0 0<br> 3 25 1 0 0 0 0<br> 4 6 2 0 0 0 0<br> 4 7 1 0 0 0 0<br> 5 9 2 0 0 0 0<br> 5 10 1 0 0 0 0<br> 6 11 1 0 0 0 0<br> 6 26 1 0 0 0 0<br> 7 12 2 0 0 0 0<br> 7 27 1 0 0 0 0<br> 8 11 2 0 0 0 0<br> 8 12 1 0 0 0 0<br> 8 15 1 0 0 0 0<br> 9 16 1 0 0 0 0<br> 9 28 1 0 0 0 0<br> 10 17 2 0 0 0 0<br> 10 29 1 0 0 0 0<br> 11 30 1 0 0 0 0<br> 12 31 1 0 0 0 0<br> 13 18 2 0 0 0 0<br> 13 32 1 0 0 0 0<br> 14 33 1 0 0 0 0<br> 15 20 2 0 0 0 0<br> 15 21 1 0 0 0 0<br> 16 19 2 0 0 0 0<br> 16 34 1 0 0 0 0<br> 17 19 1 0 0 0 0<br> 17 35 1 0 0 0 0<br> 18 36 1 0 0 0 0<br> 19 37 1 0 0 0 0<br> 20 22 1 0 0 0 0<br> 20 38 1 0 0 0 0<br> 21 23 2 0 0 0 0<br> 21 39 1 0 0 0 0<br> 22 24 2 0 0 0 0<br> 22 40 1 0 0 0 0<br> 23 24 1 0 0 0 0<br> 23 41 1 0 0 0 0<br> 24 42 1 0 0 0 0<br>M END
Compound Name
Bifonazole
CID
2378
Molecular Formula
C22H18N2
Molecular Weight
310
No. Hydrogen Bond Acceptors
1
Similar Applications
Bifonazole on Lux 5µm Amylose-2 in NP
20529
Chiral
Bifonazole on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20506
Chiral
Bifonazole on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20486
Chiral
Bifonazole on Lux 5µm Cellulose-4 in NP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20343
Chiral
Bifonazole on Lux 5µm Cellulose-3 in RP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20333
Chiral
Bifonazole on Lux 5µm Cellulose-2 in RP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20208
Chiral
Bifonazole on Lux 5µm Cellulose-4 in RP
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
20172
Chiral
Bifonazole on Lux 5µm Cellulose-3 in NP
Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
20106
Chiral
RP Enantioseparation of Bifonazole on Lux Cellulose-2
Lux 3 µm Cellulose-2, LC Column 150 x 2 mm, Ea
19400
Chiral
Bifonazole on Lux 5 µm Cellulose-1 by Chiral SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18855
Chiral
Bifonazole on Lux 5 µm Cellulose-2 by Chiral SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
18854
Chiral
Bifonazole on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17464
Chiral
Bifonazole on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17463