Miconazole on Lux 5µm Cellulose-3 in PO

Miconazole on Lux 5µm Cellulose-3 in PO
LC Conditions
Column

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

Brand

Lux

Part No

00G-4493-E0

Phase Name

Cellulose-3

Elution Type

Isocratic

Mobile Phase

A: MeOH / IPA (90:10) DEA (0.1%)

Gradient Profile

Step No.

Time(min)

%A

%B

1

0

100

0

Flow Rate

1.00 mL/min

Temperature

22°C

Detection

UV-Vis Abs.-Variable Wave.(UV) @ (22°C)

Detection Info
Sample Notes

SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-3 4 x 3.0 mm, 10/Pk Part No.: AJ0-8622 - Holder Part No.: KJ0-4282

Order Items Used in This Application

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea
00G-4493-E0

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

View Product

  • 1. Miconazole
  • 2. Miconazole
-OEChem-06211003152D<br><br> 39 41  0     1  0  0  0  0  0999 V2000<br>    4.5981   -0.7500    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301   -3.7500    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    3.7500    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    3.7500    0.0000 Cl  0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    0.7500    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1962    1.7500    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.6962    3.2888    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301    0.2500    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    7.1962    0.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301   -0.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641    1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1962   -1.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    2.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.0052    2.3378    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3871    2.3378    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.4641   -2.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1962   -2.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.3301   -2.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.6962    3.2888    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.5981    3.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    3.7500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    2.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.8660    3.2500    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.5940   -0.1750    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.4082    0.1674    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.8067    0.8577    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.0747    1.6423    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6762    2.3326    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7331   -0.9400    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.5948    2.1462    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.7975    2.1462    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.9272   -2.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.7331   -2.5600    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.0606    3.7904    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    1.1300    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7320    4.3700    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.3291    1.9400    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1 12  1  0  0  0  0<br>  2 19  1  0  0  0  0<br>  3 21  1  0  0  0  0<br>  4 25  1  0  0  0  0<br>  5  8  1  0  0  0  0<br>  5 11  1  0  0  0  0<br>  6  9  1  0  0  0  0<br>  6 15  1  0  0  0  0<br>  6 16  1  0  0  0  0<br>  7 16  2  0  0  0  0<br>  7 20  1  0  0  0  0<br>  8  9  1  0  0  0  0<br>  8 10  1  0  0  0  0<br>  8 26  1  0  0  0  0<br>  9 27  1  0  0  0  0<br>  9 28  1  0  0  0  0<br> 10 12  2  0  0  0  0<br> 10 13  1  0  0  0  0<br> 11 14  1  0  0  0  0<br> 11 29  1  0  0  0  0<br> 11 30  1  0  0  0  0<br> 12 17  1  0  0  0  0<br> 13 18  2  0  0  0  0<br> 13 31  1  0  0  0  0<br> 14 21  2  0  0  0  0<br> 14 22  1  0  0  0  0<br> 15 20  2  0  0  0  0<br> 15 32  1  0  0  0  0<br> 16 33  1  0  0  0  0<br> 17 19  2  0  0  0  0<br> 17 34  1  0  0  0  0<br> 18 19  1  0  0  0  0<br> 18 35  1  0  0  0  0<br> 20 36  1  0  0  0  0<br> 21 23  1  0  0  0  0<br> 22 24  2  0  0  0  0<br> 22 37  1  0  0  0  0<br> 23 25  2  0  0  0  0<br> 23 38  1  0  0  0  0<br> 24 25  1  0  0  0  0<br> 24 39  1  0  0  0  0<br>M  END
Compound Name

Miconazole

CID

4189

Molecular Formula

C18H14Cl4N2O

Molecular Weight

416

No. Hydrogen Bond Acceptors

2

Similar Applications

Reversed Phase

USP Miconazole Nitrate – Assay and Organic Impurities; Organic Impurities Standard solution on Kinetex 2.6 µm Phenyl-Hexyl 100 x 4.6 mm using Waters ACQUITY I-Class

Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 100 x 4.6 mm, Ea

26865

Reversed Phase

USP Miconazole Nitrate – Assay and Organic Impurities; Assay System Suitability solution on Kinetex 2.6 µm Phenyl-Hexyl 100 x 4.6 mm using Waters ACQUITY I-Class

Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 100 x 4.6 mm, Ea

26864

Reversed Phase

USP Miconazole Nitrate – Assay and Organic Impurities; Assay Standard solution on Kinetex 2.6 µm Phenyl-Hexyl 100 x 4.6 mm using Waters ACQUITY I-Class

Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 100 x 4.6 mm, Ea

26863

Chiral

Miconazole on Lux 5µm Cellulose-3 in PO

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20359

Chiral

Miconazole on Lux 5µm Cellulose-4 in NP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

20342

Chiral

Miconazole on Lux 5µm Cellulose-3 in RP

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20290

Chiral

Miconazole on Lux 5µm Cellulose-2 in RP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

20226

Chiral

Miconazole on Lux 5µm Cellulose-4 in NP

Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea

20156

Chiral

Miconazole on Lux 5µm Cellulose-3 in NP

Lux 5 µm Cellulose-3, LC Column 250 x 4.6 mm, Ea

20129

Chiral

Miconazole on Lux 5µm Cellulose-2 in NP

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

20124

RP Enantioseparation of Miconazole on Lux Amylose-2

19431

Chiral

RP Enantioseparation of Miconaxole on Lux Cellulose-2

Lux 3 µm Cellulose-2, LC Column 150 x 2 mm, Ea

19403

Chiral

Miconazole on Lux 5µ Cellulose-1 250 x 4.6mm in NP

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17659

Chiral

Miconazole on Lux Cellulose-1

Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea

17369

Chiral

Miconazole on Lux Cellulose-2

Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea

17367