Oxprenolol on Lux 5µm Cellulose-1 in NP
LC Conditions
Column
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4459-E0
Phase Name
Cellulose-1
Elution Type
Isocratic
Mobile Phase
A: Hexane / EtOH (80:20) DEA (0.1%)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
1.00 mL/min
Temperature
22°C
Detection
UV-Vis Abs.-Variable Wave.(UV) @ (22°C)
Detection Info
Sample Notes
SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-1, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8403 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Oxprenolol
- 2. Oxprenolol
-OEChem-06211003152D<br><br> 42 42 0 1 0 0 0 0 0999 V2000<br> 6.3301 -0.7500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.2500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -1.7500 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0622 2.2500 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.0622 1.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 0.7500 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 8.9282 2.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -0.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9282 3.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.7942 2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1962 -3.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -3.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.7500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.2500 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.2742 0.6674 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.6728 1.3577 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6592 0.4400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9282 2.1300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5252 2.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.4082 -0.8326 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.8067 -0.1423 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.5482 3.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.9282 4.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.3082 3.7500 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 9.4842 1.7131 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.3312 1.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 10.1042 2.7869 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 1.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 -1.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9272 -3.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 -3.5600 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 -4.3700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.3335 -2.7250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1306 -2.7250 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -1.1300 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4631 -1.9400 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 -2.8700 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 8 1 0 0 0 0<br> 1 11 1 0 0 0 0<br> 2 6 1 0 0 0 0<br> 2 33 1 0 0 0 0<br> 3 12 1 0 0 0 0<br> 3 17 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 7 1 0 0 0 0<br> 4 24 1 0 0 0 0<br> 5 6 1 0 0 0 0<br> 5 20 1 0 0 0 0<br> 5 21 1 0 0 0 0<br> 6 8 1 0 0 0 0<br> 6 22 1 0 0 0 0<br> 7 9 1 0 0 0 0<br> 7 10 1 0 0 0 0<br> 7 23 1 0 0 0 0<br> 8 25 1 0 0 0 0<br> 8 26 1 0 0 0 0<br> 9 27 1 0 0 0 0<br> 9 28 1 0 0 0 0<br> 9 29 1 0 0 0 0<br> 10 30 1 0 0 0 0<br> 10 31 1 0 0 0 0<br> 10 32 1 0 0 0 0<br> 11 12 1 0 0 0 0<br> 11 13 2 0 0 0 0<br> 12 14 2 0 0 0 0<br> 13 15 1 0 0 0 0<br> 13 34 1 0 0 0 0<br> 14 16 1 0 0 0 0<br> 14 35 1 0 0 0 0<br> 15 16 2 0 0 0 0<br> 15 36 1 0 0 0 0<br> 16 37 1 0 0 0 0<br> 17 18 1 0 0 0 0<br> 17 38 1 0 0 0 0<br> 17 39 1 0 0 0 0<br> 18 19 2 0 0 0 0<br> 18 40 1 0 0 0 0<br> 19 41 1 0 0 0 0<br> 19 42 1 0 0 0 0<br>M END
Compound Name
Oxprenolol
CID
4631
Molecular Formula
C15H23NO3
Molecular Weight
265
No. Hydrogen Bond Acceptors
4
No. Hydrogen Bond Donors
2
Similar Applications
Chiral
Oxprenolol on Lux 5µm Amylose-1 by SFC
Lux 5 µm Amylose-1, LC Column 250 x 4.6 mm, EA
23295
Chiral
Oxprenolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21297
Chiral
Oxprenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21296
Chiral
Oxprenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21295
Chiral
Oxprenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21294
Chiral
Oxprenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21293
Chiral
Oxprenolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21292
Oxprenolol on Lux 5µm Amylose-2 by SFC
21291
Oxprenolol on Lux 5µm Amylose-2 by SFC
21290
Oxprenolol on Lux 5µm Amylose-2 in NP
20553
Chiral
Oxprenolol on Lux 5µm Cellulose-1 in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
20544
Chiral
Oxprenolol on Lux 5µm Cellulose-2 in NP
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
20079
Chiral
RP Enantioseparation of Oxprenolol on Lux Cellulose-1
Lux 3 µm Cellulose-1, LC Column 150 x 2 mm, Ea
19449
Chiral
Oxprenolol on Lux 5µ Cellulose-1 250 x 4.6mm in NP
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17664
Chiral
Oxprenolol on Lux Cellulose-2
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
17482
Chiral
Oxprenolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17481