Cannabinoids and synthetic opiates by GCMS on a ZB-5MS

Cannabinoids and synthetic opiates by GCMS on a ZB-5MS
GC Conditions
Column

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

Part No

7FD-G010-08

Phase Name

ZB-5MS

Injection

Splitless @ 250°C

Carrier Gas

Constant Flow Helium, 1.2 mL/min

Detection

Mass Selective (MSD) @ (320°C)

Detection Info
Sample Notes

Sample is derivatized with BSTFA at 70ºC for 30 minutes. Sim mode: Methadone (294), THC (371), THC-OH (371), THC-COOH (473), Buprenorphine (450)

Order Items Used in This Application

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
7FD-G010-08

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

View Product

  • 1. Methadone
  • 2. THC
  • 3. THC-OH
  • 4. THC-COOH
  • 5. Buprenorphine
-OEChem-06211003152D<br><br> 50 51  0     1  0  0  0  0  0999 V2000<br>    7.1454    0.8660    0.0000 O   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.9397   -0.3008    0.0000 N   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6454    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.6454    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7057    0.3420    0.0000 C   0  0  3  0  0  0  0  0  0  0  0  0<br>    5.6454   -1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6454    1.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.6454    0.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.5321    1.3268    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.1454   -0.8660    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5115   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7794    1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7794   -1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5115    1.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.0000    0.0413    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.1133   -1.2855    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.1454   -0.8660    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5115   -2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7794    2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7794   -2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5115    2.5000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6454   -3.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6454    3.0000    0.0000 C   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2200   -0.4510    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.7531    0.6106    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.9070    0.6327    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.1427    1.4345    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.4244    1.9374    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.9215    1.2192    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    6.5628   -1.0781    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.2531   -1.4766    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0484   -1.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2425    1.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2425   -1.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0484    1.1900    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.2120    0.6239    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.4174    0.2533    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    1.7880   -0.5414    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    2.5027   -1.3931    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.2209   -1.8961    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    3.7239   -1.1779    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.1454   -1.4860    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.7654   -0.8660    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    8.1454   -0.2460    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0484   -2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2425    2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    4.2425   -2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    7.0484    2.8100    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6454   -3.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>    5.6454    3.6200    0.0000 H   0  0  0  0  0  0  0  0  0  0  0  0<br>  1  8  2  0  0  0  0<br>  2  5  1  0  0  0  0<br>  2 15  1  0  0  0  0<br>  2 16  1  0  0  0  0<br>  3  4  1  0  0  0  0<br>  3  6  1  0  0  0  0<br>  3  7  1  0  0  0  0<br>  3  8  1  0  0  0  0<br>  4  5  1  0  0  0  0<br>  4 24  1  0  0  0  0<br>  4 25  1  0  0  0  0<br>  5  9  1  0  0  0  0<br>  5 26  1  0  0  0  0<br>  6 11  2  0  0  0  0<br>  6 13  1  0  0  0  0<br>  7 12  2  0  0  0  0<br>  7 14  1  0  0  0  0<br>  8 10  1  0  0  0  0<br>  9 27  1  0  0  0  0<br>  9 28  1  0  0  0  0<br>  9 29  1  0  0  0  0<br> 10 17  1  0  0  0  0<br> 10 30  1  0  0  0  0<br> 10 31  1  0  0  0  0<br> 11 18  1  0  0  0  0<br> 11 32  1  0  0  0  0<br> 12 19  1  0  0  0  0<br> 12 33  1  0  0  0  0<br> 13 20  2  0  0  0  0<br> 13 34  1  0  0  0  0<br> 14 21  2  0  0  0  0<br> 14 35  1  0  0  0  0<br> 15 36  1  0  0  0  0<br> 15 37  1  0  0  0  0<br> 15 38  1  0  0  0  0<br> 16 39  1  0  0  0  0<br> 16 40  1  0  0  0  0<br> 16 41  1  0  0  0  0<br> 17 42  1  0  0  0  0<br> 17 43  1  0  0  0  0<br> 17 44  1  0  0  0  0<br> 18 22  2  0  0  0  0<br> 18 45  1  0  0  0  0<br> 19 23  2  0  0  0  0<br> 19 46  1  0  0  0  0<br> 20 22  1  0  0  0  0<br> 20 47  1  0  0  0  0<br> 21 23  1  0  0  0  0<br> 21 48  1  0  0  0  0<br> 22 49  1  0  0  0  0<br> 23 50  1  0  0  0  0<br>M  END
Compound Name

Methadone

CID

4095

Molecular Formula

C21H27NO

Molecular Weight

309

No. Hydrogen Bond Acceptors

2

Similar Applications

Reversed Phase

Analysis of Fat soluble Vitamins (A, E and K) Using a Kinetex 2.6u Biphenyl 50x3.0mm Column

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

26505

Reversed Phase

Extraction of Pain Panel (Drugs of Abuse) in Human Serum from Phree PLR Using a Kinetex 2.6u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

26504

Reversed Phase

Fast Screening Method for 86 Forensic Analytes in Human Urine by LC-MS/MS

Luna 5 µm C18(2) 100 Å, LC Column 50 x 2 mm, Ea

25864

Reversed Phase

7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea

23560

Reversed Phase

Drugs of Abuse by LCMS using Kinetex 1.7u Biphenyl 50x2.1mm

Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

23445

Reversed Phase

Drugs of Abuse by LCMS using Kinetex 1.7u EVO C18 50x2.1mm

Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea

23444

Reversed Phase

Drugs of Abuse by LCMS using Luna Omega 1.6u C18 50x2.1mm

Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA

23443

Improved Performance

ZB-5MSplus Drugs of Abuse

Zebron ZB-5MSplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, EA

23258

Reversed Phase

Full Pain Panel using Kinetex 2.6u Biphenyl 50x2.1mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

22122

Reversed Phase

Fast Pain Panel using Kinetex 2.6 u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22121

Reversed Phase

Full Pain Panel using Kinetex 5um Biphenyl 50x3.0mm

Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22120

Reversed Phase

Pain Panel Opiates using Kinetex 2.6u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22108

Reversed Phase

Full Pain Panel using Kinetex 2.6u Biphenyl 50x3.0mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea

22104

Reversed Phase

Opiates using Kinetex 2.6u Biphenyl 50x2.1mm

Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea

21972

Reversed Phase

Pain Panel using Kinetex Phenyl Hexyl 2.6u 50x4.6mm

Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea

20852

Reversed Phase

Pain Panel using Strata-X-Drug B and Kinetex Phenyl-Hexyl 2.6u 50x4.6mm

Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea

20847

Standard

Cannabinoids and synthetic opiates by GCMS on a ZB-5MS

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

20810

Reversed Phase

Pain Panel Opiates by LC/MS using Kinetex 2.6u C18 50x2.1mm

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

20692

Reversed Phase

Pain Panel/Drug Screening by LCMS using Kinetex 2.6u C18 50x3.0mm

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 3 mm, Ea

20689

Reversed Phase

Pain Panel Mix-41 in Human Urine on Luna 3u, PFP(2), 50x3 by LC-MS/MS

Luna 3 µm PFP(2) 100 Å, LC Column 50 x 3 mm, Ea

20594

Reversed Phase

Pain Panel Mix-41 in Human Urine on Kinetex 2.6u, PFP, 50x3 by LC-MS/MS

Kinetex 2.6 µm PFP 100 Å, LC Column 50 x 3 mm, Ea

20593

Reversed Phase

Pain Panel Mix-41 in Human Urine on Kinetex 2.6u, Phenyl-Hexyl, 50x2.1 by LC-MS/MS

Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 2.1 mm, Ea

20592

Reversed Phase

Pain Panel Mix-41 in Human Urine on Kinetex 2.6u, XB-C18, 50x3 by LC-MS/MS

Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 3 mm, Ea

20591

Reversed Phase

Pain Panel Mix-41 in Human Urine on Kinetex 2.6u, C18, 50x3 by LC-MS/MS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 3 mm, Ea

20590

Reversed Phase

LC/MS/MS Analysis of Methadone from urine using Strata-X-Drug B on a Kinetex C18 2.6µm, 50x2.1mm

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19703

Reversed Phase

Pain Panel on Kinetex C18 2.6µm 50 x 2.1 mm by LC/MS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19177

Reversed Phase

Pain Panel with and without sample focusing on Kinetex C18 2.6µm 50 x 2.1 mm by LC/MS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

19167

Reversed Phase

Pain panel extracted from human urine at cutoff - Kinetex C18 2.6µm 50x2.1mm LCMSMS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

18850

Reversed Phase

Extraction of Methadone using Strata X-C on Kinetex 2.6µm C18 50 x 2.1mm ID with Acquity UPLC MSMS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

18651

Reversed Phase

Extraction of Methadone using strata X-C on Kinetex 2.6µm C18 50 x 2.1mm ID by LCMS

Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea

18649

Application Specific

Methadone from urine by Strata-XC on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18485

Application Specific

Drug screen by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18175

Application Specific

Methadone from urine by Screen C on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

18021

Application Specific

Methadone by MSD on a ZB-Drug1

Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

17804

Methadone by MSD on a ZB-5MSi

17790

Standard

Methadone by MSD on a ZB-5MS

Zebron ZB-5MS, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea

16742

Methadone by MSD on a ZB-XLB

16696

Methadone by MSD on a ZB-1MS

16692

Drug Screen on Zebron ZB-1MS 12m x 0.20mm x 0.33um

15869

Standard

Drug Screen on Zebron ZB-5MS 20m x 0.18mm x 0.18um

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

15868

Drug Screen on Zebron ZB-1MS 20m x 0.18mm x 0.18um

15867

Standard

Opiates on ZB5ms 20x0.18x0.18

Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea

15569

Standard

Opiates on ZB-5

Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea

14788

Standard

Drugs of Abuse

Zebron ZB-1, GC Cap. Column 15 m x 0.25 mm x 0.25 µm, Ea

6567