Cannabinoids and synthetic opiates by GCMS on a ZB-5MS
GC Conditions
Column
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
Part No
7FD-G010-08
Phase Name
ZB-5MS
Injection
Splitless @ 250°C
Carrier Gas
Constant Flow Helium, 1.2 mL/min
Detection
Mass Selective (MSD) @ (320°C)
Detection Info
Sample Notes
Sample is derivatized with BSTFA at 70ºC for 30 minutes. Sim mode: Methadone (294), THC (371), THC-OH (371), THC-COOH (473), Buprenorphine (450)
Order Items Used in This Application
- 1. Methadone
- 2. THC
- 3. THC-OH
- 4. THC-COOH
- 5. Buprenorphine
-OEChem-06211003152D<br><br> 50 51 0 1 0 0 0 0 0999 V2000<br> 7.1454 0.8660 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9397 -0.3008 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 0.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.6454 0.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7057 0.3420 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 5.6454 -1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 1.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.6454 0.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.5321 1.3268 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1454 -0.8660 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5115 -1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7794 1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7794 -1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5115 1.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.0000 0.0413 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.1133 -1.2855 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1454 -0.8660 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5115 -2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7794 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7794 -2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5115 2.5000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 -3.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 3.0000 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2200 -0.4510 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.7531 0.6106 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9070 0.6327 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.1427 1.4345 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.4244 1.9374 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.9215 1.2192 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.5628 -1.0781 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.2531 -1.4766 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0484 -1.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2425 1.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2425 -1.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0484 1.1900 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.2120 0.6239 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.4174 0.2533 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1.7880 -0.5414 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.5027 -1.3931 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.2209 -1.8961 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7239 -1.1779 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1454 -1.4860 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.7654 -0.8660 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 8.1454 -0.2460 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0484 -2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2425 2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.2425 -2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.0484 2.8100 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 -3.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6454 3.6200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 8 2 0 0 0 0<br> 2 5 1 0 0 0 0<br> 2 15 1 0 0 0 0<br> 2 16 1 0 0 0 0<br> 3 4 1 0 0 0 0<br> 3 6 1 0 0 0 0<br> 3 7 1 0 0 0 0<br> 3 8 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 24 1 0 0 0 0<br> 4 25 1 0 0 0 0<br> 5 9 1 0 0 0 0<br> 5 26 1 0 0 0 0<br> 6 11 2 0 0 0 0<br> 6 13 1 0 0 0 0<br> 7 12 2 0 0 0 0<br> 7 14 1 0 0 0 0<br> 8 10 1 0 0 0 0<br> 9 27 1 0 0 0 0<br> 9 28 1 0 0 0 0<br> 9 29 1 0 0 0 0<br> 10 17 1 0 0 0 0<br> 10 30 1 0 0 0 0<br> 10 31 1 0 0 0 0<br> 11 18 1 0 0 0 0<br> 11 32 1 0 0 0 0<br> 12 19 1 0 0 0 0<br> 12 33 1 0 0 0 0<br> 13 20 2 0 0 0 0<br> 13 34 1 0 0 0 0<br> 14 21 2 0 0 0 0<br> 14 35 1 0 0 0 0<br> 15 36 1 0 0 0 0<br> 15 37 1 0 0 0 0<br> 15 38 1 0 0 0 0<br> 16 39 1 0 0 0 0<br> 16 40 1 0 0 0 0<br> 16 41 1 0 0 0 0<br> 17 42 1 0 0 0 0<br> 17 43 1 0 0 0 0<br> 17 44 1 0 0 0 0<br> 18 22 2 0 0 0 0<br> 18 45 1 0 0 0 0<br> 19 23 2 0 0 0 0<br> 19 46 1 0 0 0 0<br> 20 22 1 0 0 0 0<br> 20 47 1 0 0 0 0<br> 21 23 1 0 0 0 0<br> 21 48 1 0 0 0 0<br> 22 49 1 0 0 0 0<br> 23 50 1 0 0 0 0<br>M END
Compound Name
Methadone
CID
4095
Molecular Formula
C21H27NO
Molecular Weight
309
No. Hydrogen Bond Acceptors
2
Similar Applications
Reversed Phase
Analysis of Fat soluble Vitamins (A, E and K) Using a Kinetex 2.6u Biphenyl 50x3.0mm Column
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
26505
Reversed Phase
Extraction of Pain Panel (Drugs of Abuse) in Human Serum from Phree PLR Using a Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
26504
Reversed Phase
Fast Screening Method for 86 Forensic Analytes in Human Urine by LC-MS/MS
Luna 5 µm C18(2) 100 Å, LC Column 50 x 2 mm, Ea
25864
Reversed Phase
7.5 min Pain Panel on Kinetex 2.6µm Biphenyl, 30x2.1mm ESI+
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 30 x 2.1 mm, Ea
23560
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u Biphenyl 50x2.1mm
Kinetex 1.7 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
23445
Reversed Phase
Drugs of Abuse by LCMS using Kinetex 1.7u EVO C18 50x2.1mm
Kinetex 1.7 µm EVO C18 100 Å, LC Column 50 x 2.1 mm, Ea
23444
Reversed Phase
Drugs of Abuse by LCMS using Luna Omega 1.6u C18 50x2.1mm
Luna Omega 1.6µm C18 100Å, LC Column 50 x 2.1 mm, EA
23443
Improved Performance
ZB-5MSplus Drugs of Abuse
Zebron ZB-5MSplus, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, EA
23258
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
22122
Reversed Phase
Fast Pain Panel using Kinetex 2.6 u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22121
Reversed Phase
Full Pain Panel using Kinetex 5um Biphenyl 50x3.0mm
Kinetex 5 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22120
Reversed Phase
Pain Panel Opiates using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22108
Reversed Phase
Full Pain Panel using Kinetex 2.6u Biphenyl 50x3.0mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 3.0 mm, Ea
22104
Reversed Phase
Opiates using Kinetex 2.6u Biphenyl 50x2.1mm
Kinetex 2.6 µm Biphenyl 100 Å, LC Column 50 x 2.1 mm, Ea
21972
Reversed Phase
Pain Panel using Kinetex Phenyl Hexyl 2.6u 50x4.6mm
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea
20852
Reversed Phase
Pain Panel using Strata-X-Drug B and Kinetex Phenyl-Hexyl 2.6u 50x4.6mm
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 4.6 mm, Ea
20847
Standard
Cannabinoids and synthetic opiates by GCMS on a ZB-5MS
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
20810
Reversed Phase
Pain Panel Opiates by LC/MS using Kinetex 2.6u C18 50x2.1mm
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
20692
Reversed Phase
Pain Panel/Drug Screening by LCMS using Kinetex 2.6u C18 50x3.0mm
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 3 mm, Ea
20689
Reversed Phase
Pain Panel Mix-41 in Human Urine on Luna 3u, PFP(2), 50x3 by LC-MS/MS
Luna 3 µm PFP(2) 100 Å, LC Column 50 x 3 mm, Ea
20594
Reversed Phase
Pain Panel Mix-41 in Human Urine on Kinetex 2.6u, PFP, 50x3 by LC-MS/MS
Kinetex 2.6 µm PFP 100 Å, LC Column 50 x 3 mm, Ea
20593
Reversed Phase
Pain Panel Mix-41 in Human Urine on Kinetex 2.6u, Phenyl-Hexyl, 50x2.1 by LC-MS/MS
Kinetex 2.6 µm Phenyl-Hexyl 100 Å, LC Column 50 x 2.1 mm, Ea
20592
Reversed Phase
Pain Panel Mix-41 in Human Urine on Kinetex 2.6u, XB-C18, 50x3 by LC-MS/MS
Kinetex 2.6 µm XB-C18 100 Å, LC Column 50 x 3 mm, Ea
20591
Reversed Phase
Pain Panel Mix-41 in Human Urine on Kinetex 2.6u, C18, 50x3 by LC-MS/MS
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 3 mm, Ea
20590
Reversed Phase
LC/MS/MS Analysis of Methadone from urine using Strata-X-Drug B on a Kinetex C18 2.6µm, 50x2.1mm
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19703
Reversed Phase
Pain Panel on Kinetex C18 2.6µm 50 x 2.1 mm by LC/MS
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19177
Reversed Phase
Pain Panel with and without sample focusing on Kinetex C18 2.6µm 50 x 2.1 mm by LC/MS
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
19167
Reversed Phase
Pain panel extracted from human urine at cutoff - Kinetex C18 2.6µm 50x2.1mm LCMSMS
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
18850
Reversed Phase
Extraction of Methadone using Strata X-C on Kinetex 2.6µm C18 50 x 2.1mm ID with Acquity UPLC MSMS
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
18651
Reversed Phase
Extraction of Methadone using strata X-C on Kinetex 2.6µm C18 50 x 2.1mm ID by LCMS
Kinetex 2.6 µm C18 100 Å, LC Column 50 x 2.1 mm, Ea
18649
Application Specific
Methadone from urine by Strata-XC on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18485
Application Specific
Drug screen by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18175
Application Specific
Methadone from urine by Screen C on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
18021
Application Specific
Methadone by MSD on a ZB-Drug1
Zebron ZB-Drug-1, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
17804
Methadone by MSD on a ZB-5MSi
17790
Standard
Methadone by MSD on a ZB-5MS
Zebron ZB-5MS, GC Cap. Column 10 m x 0.18 mm x 0.18 µm, Ea
16742
Methadone by MSD on a ZB-XLB
16696
Methadone by MSD on a ZB-1MS
16692
Drug Screen on Zebron ZB-1MS 12m x 0.20mm x 0.33um
15869
Standard
Drug Screen on Zebron ZB-5MS 20m x 0.18mm x 0.18um
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
15868
Drug Screen on Zebron ZB-1MS 20m x 0.18mm x 0.18um
15867
Standard
Opiates on ZB5ms 20x0.18x0.18
Zebron ZB-5MS, GC Cap. Column 20 m x 0.18 mm x 0.18 µm, Ea
15569
Standard
Opiates on ZB-5
Zebron ZB-5, GC Cap. Column 30 m x 0.25 mm x 0.25 µm, Ea
14788
Standard
Drugs of Abuse
Zebron ZB-1, GC Cap. Column 15 m x 0.25 mm x 0.25 µm, Ea
6567