Bupranolol on Lux 5µm Cellulose-2 by SFC
LC Conditions
Column
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
Brand
Lux
Part No
00G-4457-E0
Phase Name
Cellulose-2
Elution Type
Isocratic
Mobile Phase
A: CO2/(Methanol + 0.5% IPA) 80:20 (v/v)
Gradient Profile
Step No.
Time(min)
%A
%B
1
0
100
0
Flow Rate
3.00 mL/min
Temperature
30°C
Detection
UV-Vis Abs.-Diode Array (PDA) @ (30°C)
Detection Info
Sample Notes
Courtesy of Katrijn De Klerck, Debby Mangelings and Yvan Vander Heyden, Department of Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel, Brussels, Belgium. Results of this analysis yielded: Alpha >1.1 and Resolution >1.5 SecurityGuard™ Guard Cartridge System extends column lifetime. - SecurityGuard Cartridges, Lux Cellulose-2, 4 x 3.0mm ID, 10/Pk Part No.: AJ0-8366 - Holder Part No.: KJ0-4282
Order Items Used in This Application
- 1. Bupranolol
- 2. Bupranolol
-OEChem-06211003142D<br><br> 40 40 0 1 0 0 0 0 0999 V2000<br> 2.0000 -1.6830 0.0000 Cl 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.3170 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -0.6830 0.0000 O 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 2.3170 0.0000 N 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3301 2.8170 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 1.3170 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 0.8170 0.0000 C 0 0 3 0 0 0 0 0 0 0 0 0<br> 7.1962 3.3170 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.8301 3.6830 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8301 1.9510 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -0.1830 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -1.6830 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -2.1830 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -2.1830 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 -3.1830 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -3.6830 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.8660 -3.1830 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.4641 -3.6830 0.0000 C 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.9272 2.6270 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.6762 0.7344 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0747 1.4246 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.5981 1.4370 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.5062 2.7800 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.7331 3.6270 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.8862 3.8539 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.3671 3.9930 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.5201 4.2200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2932 3.3730 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.2932 1.6410 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.1401 1.4140 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 7.3671 2.2610 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 4.8101 -0.7656 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.2087 -0.0754 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 1.9370 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1350 -1.8730 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 3.7320 -4.3030 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 2.3291 -3.4930 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.1541 -4.2200 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 6.0010 -3.9930 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 5.7741 -3.1461 0.0000 H 0 0 0 0 0 0 0 0 0 0 0 0<br> 1 14 1 0 0 0 0<br> 2 7 1 0 0 0 0<br> 2 34 1 0 0 0 0<br> 3 11 1 0 0 0 0<br> 3 12 1 0 0 0 0<br> 4 5 1 0 0 0 0<br> 4 6 1 0 0 0 0<br> 4 19 1 0 0 0 0<br> 5 8 1 0 0 0 0<br> 5 9 1 0 0 0 0<br> 5 10 1 0 0 0 0<br> 6 7 1 0 0 0 0<br> 6 20 1 0 0 0 0<br> 6 21 1 0 0 0 0<br> 7 11 1 0 0 0 0<br> 7 22 1 0 0 0 0<br> 8 23 1 0 0 0 0<br> 8 24 1 0 0 0 0<br> 8 25 1 0 0 0 0<br> 9 26 1 0 0 0 0<br> 9 27 1 0 0 0 0<br> 9 28 1 0 0 0 0<br> 10 29 1 0 0 0 0<br> 10 30 1 0 0 0 0<br> 10 31 1 0 0 0 0<br> 11 32 1 0 0 0 0<br> 11 33 1 0 0 0 0<br> 12 13 1 0 0 0 0<br> 12 14 2 0 0 0 0<br> 13 15 2 0 0 0 0<br> 13 35 1 0 0 0 0<br> 14 17 1 0 0 0 0<br> 15 16 1 0 0 0 0<br> 15 18 1 0 0 0 0<br> 16 17 2 0 0 0 0<br> 16 36 1 0 0 0 0<br> 17 37 1 0 0 0 0<br> 18 38 1 0 0 0 0<br> 18 39 1 0 0 0 0<br> 18 40 1 0 0 0 0<br>M END
Compound Name
Bupranolol
CID
2475
Molecular Formula
C14H22ClNO2
Molecular Weight
271
No. Hydrogen Bond Acceptors
3
No. Hydrogen Bond Donors
2
Similar Applications
Chiral
Bupranolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21078
Chiral
Bupranolol on Lux 5µm Cellulose-4 by SFC
Lux 5 µm Cellulose-4, LC Column 250 x 4.6 mm, Ea
21077
Chiral
Bupranolol on Lux 5µm Cellulose-2 by SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
21076
Chiral
Bupranolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21075
Chiral
Bupranolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21074
Chiral
Bupranolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21073
Chiral
Bupranolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21072
Chiral
Bupranolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21071
Chiral
Bupranolol on Lux 5µm Cellulose-1 by SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
21070
Chiral
b-Blockers (Bupranolol) on Lux 5 µm Cellulose-1 by Chiral SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18968
Chiral
b-Blockers (Bupranolol) on Lux 5 µm Cellulose-2 by Chiral SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
18967
Chiral
b-Blockers (Bupranolol) on Lux 5 µm Cellulose-1 by Chiral SFC
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
18957
Chiral
b-Blockers (Bupranolol) on Lux 5 µm Cellulose-2 by Chiral SFC
Lux 5 µm Cellulose-2, LC Column 250 x 4.6 mm, Ea
18956
Chiral
Bupranolol on Lux Cellulose-1
Lux 5 µm Cellulose-1, LC Column 250 x 4.6 mm, Ea
17317